Verified by manufacturer 1 month ago
100 mm thickness
Autoclaved aerated concrete (AAC) blocks.
Walls and columns.
Mannok Aircrete thermal blocks are manufactured using autoclaved aerated concrete at the Mannok manufacturing facility in Derrylin, Co. Fermanagh, N. Ireland. They are supplied in response to customer demand for a building block with efficient thermal properties combined with a high strength to weight ratio.
Features and benefits:
Color | Grey |
Finish | Textured |
Material | Autoclaved aerated concrete (AAC) Guidance for specification option: Autoclaved aerated concrete (AAC). |
Shape | Rectangle |
Length | 440 mm |
Width | 65 mm 100 mm 150 mm 215 mm |
Height | 75 mm 100 mm 115 mm 125 mm 140 mm |
Uniclass | |
CAWS | F10/360 Autoclaved aerated concrete (AAC) common blockwork F10/37 Autoclaved aerated concrete (AAC) common blockwork F10/370 Thin-joint autoclaved aerated concrete (AAC) common blockwork F10/39 Thin joint autoclaved aerated concrete (AAC) common blockwork |
Product range |
Standard | To BS EN 771-4 and BS EN 13501-1: A1. |
Mean compressive strength (minimum) | 10.4 N/mm². |
Category | II. |
Thermal conductivity (maximum) | 0.19 W/mK. |
Work sizes (length x width x height) | 440 x 75 x 215 mm.Guidance for specification option: Special order, thermal resistance: 0.39 m²K/W. 440 x 100 x 215 mm.Guidance for specification option: Thermal resistance: 0.53 m²K/W. 440 x 115 x 215 mm.Guidance for specification option: Special order, thermal resistance: 0.61 m²K/W. 440 x 125 x 215 mm.Guidance for specification option: Special order, thermal resistance: 0.66 m²K/W. 440 x 140 x 215 mm.Guidance for specification option: Thermal resistance: 0.74 m²K/W. 440 x 150 x 215 mm.Guidance for specification option: Thermal resistance: 0.79 m²K/W. 440 x 200 x 215 mm.Guidance for specification option: Special order, thermal resistance: 1.05 m²K/W. 440 x 215 x 215 mm.Guidance for specification option: Thermal resistance: 1.13 m²K/W. 440 x 250 x 215 mm.Guidance for specification option: Special order, thermal resistance: 1.32 m²K/W. 440 x 275 x 215 mm.Guidance for specification option: Special order, thermal resistance: 1.45 m²K/W. 440 x 300 x 215 mm.Guidance for specification option: Thermal resistance: 1.58 m²K/W. 215 x 100 x 65 mm.440 x 100 x 100 mm.440 x 140 x 100 mm.440 x 150 x 100 mm.440 x 150 x 150 mm. |
Accessories or special shapes | |
Type | Coursing blocks. |
Tolerance category | Manufacturer guidanceDimensional tolerance category: D1. |
Density | 800 kg/m³. |
Reaction to fire | Class A1 to BS EN 13501-1. |
Moisture movement | < 0.4 mm/m.Manufacturer guidanceAlso dimensional stability. |
Thickness | 100 mm. |
Thermal resistance | 0.53 m²K/W. |
Edges | Square. |