Verified by manufacturer 1 month ago
Solid Collection
BS EN 13501-1
Certificate type
ISO 9001 Quality Management
Certificate type
UL Certified
Certificate type
Non-combustible, A1-rated, secret fix cassette rainscreen cladding system.
Particularly suited for a wide range of architectural cladding applications on both internal and external commercial and residential projects, where a sleek/ modern facade is required.
All provided products are tested and certified in accordance with Approved Document B, Volume 2, for high-rise buildings.
Non-combustible, A1-rated, secret fix cassette rainscreen cladding system. Panels are available in different thickness options.
This system features an innovative slide and lock adjustment mechanism for enhanced secret fix hook-on carrier rail hooks.
A typical system comprises:
Cladding panel - Features and benefits:
Fixed with colour matched anti-lift fixings installed in the horizontal panel joints. Stiffeners as required are stud welded to the rear of the panel to give a mechanical, non-combustible installation with no use of glue/ adhesives. Consult manufacturers drawings for further details.
Secondary support structure - Features and benefits:
Multiple colour options are available, including:
Color | White Cream Beige Grey Black |
Finish | PVdF Painted Powder-coated Metallic Anodized |
Material | Aluminium |
Shape | Rectangle Other |
Length | 2500 mm 3200 mm 4000 mm Bespoke |
Width | 1000 mm 1250 mm 1500 mm Bespoke |
Height | 2 mm 3 mm Manufacturer guidanceSheet thickness. |
Warranty description | 40 year Guidance for specification option: Warranty available up to 40 years - consult manufacturer for details. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Thermal insulation | Rockwool Duo Slab (or equivalent, where applicable).Guidance for specification option: Insert required thickness.
|
Breather membrane | |
Material | DuPont™ Tyvek® FireCurb®.Guidance for specification option:
|
Secondary support structure | EVT II aluminium carrier rail system (hook on).Guidance for specification option: EVT II Helping Hand Brackets, System Profiles and Structural Support Profiles:
EVT II - Structural C Channels and Top-Hat Support Profiles: Comprises of aluminium or stainless steel top-hats and C-channel rails to allow brackets to be installed in isolation of stud location or increase system depth. The EVT II top-hats can also be used in their own right to replace timber batten style sub-grids. EVT II - Rails: T-profile or hanger hook profile. Consult manufacturer for details. Manufacturer guidanceConsult manufacturer for guidance. |
Cavity fire barriers | |
Horizontal | Siderise E90 I30 Open State Cavity Barriers.Manufacturer guidanceFixings: Fire tested fixings to be advised by Siderise to equivalent performance of fire barrier, fixing reference dictated by substrate. |
Vertical | Siderise E90 I30 Closed State Cavity Barriers.Siderise OSC I Cassette Inserts 100/ 50.Manufacturer guidanceFixings: Fire tested fixings to be advised by Siderise to equivalent performance of fire barrier, fixing reference dictated by substrate. |
Cladding panels | |
Material | Aluminium - 3000 series.Aluminium - 5000 series.Manufacturer guidanceFixed with JT4 FR 4 4.8 x 19 S12 - Ejot self-drill low profile dome head stainless steel, A2 grade, 4.8 x 19 mm, colour matched to panel. 2 mm aluminium alloy top-hat attached to reverse of panel using stud weld fixings. |
Panel joints | 20 mm joints in both vertical and horizontal directions.Closed joints. |
System accessories | Not required.130530 EVT II Single Thermal Pad 80 x 42 mm.130531 EVT II Double Thermal Pad 160 x 42 mm.Window flashing profile. |
Configuration/ Design | Manufacturer guidanceInsert drawing or project reference, or insert requirements. |
Thickness | 2 mm. Guidance for specification option: 5.51 kg/m². 3 mm. Guidance for specification option: 8.24 kg/m². |
Panel size | 2500 x 1000 mm. 2500 x 1250 mm. 2500 x 1500 mm. 3200 x 1000 mm. 3200 x 1250 mm. Manufacturer guidanceLength x width. |
Finish: | PVDF KYNAR 500. HYLAR 5000. FEVE. Polyester powder-coated. Manufacturer guidanceEN 1396/ AAMA 2605. |
Colour | Pure White. White. Cream. Beige. Light Grey. Manufacturer guidanceColours listed are only a sample of the possibilities available. Any RAL, NCS and NCS-S color chart can be used. On request, manufacturer can also prepare individual colours to match required specifications. |
Reaction to fire | To BS EN 13501-1, Class A1. |
Sheathing board | RCM Y Wall Board. Guidance for specification option:
|
Cavity | 50 mm open joint installation. Guidance for specification option: Measured from face of insulation to rear of panel, can be reduced by 50% at fire barrier locations or other “pinch” points. 25 mm closed joint installation. Guidance for specification option: Measured from face of insulation to rear of panel, can be reduced by 50% at fire barrier locations or other “pinch” points. Manufacturer guidanceCavity depth. |
Fixings | Supplied by RJ Facades. Guidance for specification option: Fire rated, ETA approved fixing, RJ Facades Ltd to carry out pull out test on site to determine correct fixing. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Recyclability | 100% recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 99.5 % Guidance for specification option: Up to 99.5% recycled content for aluminium sheet, and up to 75% recycled content for extruded aluminium. These values could vary depending on where the material is sourced. |
Luxe Clad A1 CP – Castellated Panel Cladding System - Rainscreen Cladding
Luxe Clad A1 IPP – Interlocking Pressed Plank Cladding System - Rainscreen Cladding
Luxe Clad A1 TFP Through Fix Panel Cladding System - Rainscreen Cladding
Luxe Clad A1® DFC - Discreet Fix Cassette Cladding System - Rainscreen Cladding