Verified by manufacturer 10 days ago
EPD
Certificate type
ISO 45001 Health and Safety Management
Certificate type
ISO 9001 Quality Management
Certificate type
Linear 30 is a 30 mm wide single glazed partition system that offers a very high (Rw 41 dB) acoustic performance compared to other single glazed systems. Ideal for offices and meeting rooms.
All sectors: Commercial, Education, Healthcare, MOD, Airport and Rail, Industrial, Hospitality, Residential and Public.
Linear 30 is a 30 mm wide single glazed partition system that features a selection of deflection heads up to +/- 25 mm.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for Radii products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Clear |
Finish | Powder-coated Anodized Polished Manufacturer guidancePolyester Powder Coated RAL, Polished & Chemically brightened, Linish & Chemically brightened, Etch & Anodise - |
Material | Aluminium Glass Manufacturer guidanceAluminium (6063 T6) / Glass |
Shape | Other |
Length | Bespoke |
Width | 30 mm |
Height | Bespoke |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process. |
Uniclass | |
CAWS | K30/10 Relocatable partition system K30/130 Relocatable partition system |
Product range |
Unit size | |
Thickness | 30 mm. |
Partition height (nominal) | Manufacturer guidanceInsert requirements. For partitions over 3 m high, please consult with manufacturer. |
Width (nominal) | Manufacturer guidanceInsert requirements. For panels over 1200 mm wide, please consult with manufacturer. |
Deflection allowance (maximum) | |
Head | No deflection 25 mm deep x 30 mm wide aluminium channel.Guidance for specification option: Surface Mounted Deflection Head ±15 mm deflection73 mm deep x 30 mm wide two part aluminium channel.Guidance for specification option: Surface Mounted Deflection Head ±25 mm deflection 83 mm deep x 30 mm wide two part aluminium channel.Guidance for specification option: Surface Mounted Deflection Head ±15 mm deflection 15 mm visible aluminium channel.Guidance for specification option: Recessed Deflection Head – Co-ordination required with ceiling contractor. ±25 mm deflection 25 mm visible aluminium channel.Guidance for specification option: Recessed Deflection Head – Co-ordination required with ceiling contractor. |
Floor | Not applicable.Manufacturer guidanceSystem does not offer deflection at floor level - consult with manufacturer for system weights. |
Verticals | Manufacturer guidanceLateral deflection available to suit design requirements - consult with manufacturer |
Panel partition type | Single glazed system. |
Framing, fixing points and joints | Floor detail: surface mounted aluminium U channel screw fixed.Floor detail: 25 mm deep x 30 mm wide as standard.Guidance for specification option: – larger base details available. Wall abutments: surface mounted aluminium U channel screw fixed into drylined partition.Wall abutments: 25 mm deep x 30 mm wide as standard.Guidance for specification option: – larger abutment details available. Corners: mitered panel to panel joint with 2 mm joint tape. |
Solid panels | |
Type | 18 mm MFC.18 mm aluminium faced MDF.19 mm veneered MDF.Manufacturer guidanceSolid Panels (to be installed into Tech Units). |
Joint treatment | |
Type | 2 mm dry joint tape between panels. 8 mm Shadow-gap around panels. |
Finish and colour | Clear – see above joint treatment. |
Glazed panels | |
Type | Single-glazed, 16.8 mm acoustic laminate glass.Manufacturer guidanceSingle centre glazed (14.8–16.8 mm): Consult with manufacturer to ensure compliance with test/assessment data. |
Integral blinds | Not suitable for single glazed systems. |
Additional features | Tech panel to incorporate room booking systems and room controls.Security post to incorporate access control devices. |
Door arrangement | |
Door frames | 25 x 40 mm rebated aluminium door frame. |
Door panels | |
Type | ALIGN - 50 mm wide double glazed door with a drop threshold – 37 dB Rw.ALIGN - 50 mm wide double glazed door with a drop threshold – 39 dB Rw.ALIGN - 50 mm wide double glazed door with a drop threshold – 42 dB Rw.HOGAN - 50 mm wide single glazed door with a drop threshold – 34 dB Rw.HOGAN - 50 mm wide single glazed door with a drop threshold – 38 dB Rw.HOGAN - 50 mm wide double glazed door with a drop threshold – 39 dB Rw.TIMBER - 54 mm wide acoustic door blank with a drop threshold seal – 30 db Rw.TIMBER - 54 mm wide acoustic door blank with a drop threshold seal – 35 db Rw.TIMBER - 64 mm wide acoustic door blank with a drop threshold seal – 40 db Rw |
Vision panels | Manufacturer guidanceApplicable with timber doors only - Consult with manufacturer. |
Ceiling | |
Type | Consult with manufacturer for interface detail. |
Panels | As Above. |
Method of support | Timber fixing point required within the ceiling/bulkhead – to be supplied by others. Consult with ceiling manufacturer for support detail – co-ordination meeting with all parties concerned to be arranged prior to internal glazing installation. |
Joint treatment | Secure fixing into timber provided above. |
Perimeters, skirtings, sills | 58 mm deep outer deflection profile as standard. |
Trims | 16 x 3 mm aluminium feature bands bonded to the faces 1 & 2 on vertical glass joints with X horizontal bands.16 x 5 mm aluminium feature bands bonded to the faces 1 & 2 on vertical glass joints with X horizontal bands.25 x 3 mm aluminium feature bands bonded to the faces 1 & 2 on vertical glass joints with X horizontal bands.25 x 5 mm aluminium feature bands bonded to the faces 1 & 2 on vertical glass joints with X horizontal bands.50 x 3 mm aluminium feature bands bonded to the faces 1 & 2 on vertical glass joints with X horizontal bands.50 x 5 mm aluminium feature bands bonded to the faces 1 & 2 on vertical glass joints with X horizontal bands. |
Hardware | Manufacturer guidanceSee appropriate door specification for applicable ironmongery options. |
Seals | Black perimeter compression seals. |
Cable management and outlets | Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics - refer to manufacturer with project specific requirements. |
Other features | Tech panels.Access control.Locking.Manufacturer guidanceConsult manufacturer for details. |
Acoustic performance | 41 dB Rw. Manufacturer guidanceTo comply to EN ISO 10140-2 and ISO 717-1: Acoustics vary according to framework/glazing. Acoustic options subject to further design development, consult manufacturer. |
Manifestation | Allowance of two rows 50 mm dots or square (minimum) Opal Frost. Artwork and custom manifestation to client design. Manufacturer guidanceIn accordance with the requirements of Approved Document K. |
StrengthGrade | 0.36 kN/m. Guidance for specification option: Standard. 0.74 kN/m. 1.5 kN/m. 3.0 kN/m. Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 Non-loadbearing screens not protecting a change in adjacent floor level of >380 mm For glass load resistance criteria, see below; - BS5234 not applied to “all glass partition screens” - Nominal line load criteria of “short-term impact load” utilized - 0.36kN/m applied as linear load at 1100 mm above FFL - Glass deflection limited to L/65 or 25 mm, whichever is less under load - Maximum deflection and stress in accordance with the glass performance requirements of EN572/EN12150/EN12543/EN14179 (where heat soaked) - Building regulations Part N (BS6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” - 0.36kN/m (default load) - 0.74kN/m - 1.5kN/m BS 6180:2011 Barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm Horizontal uniformly distributed line load 1100 mm above FFL (Glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings) Structural Glass based on line-load and attendant UDL + point load - 0.74kN/m - 1.5kN/m - 3.0kN/m |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Glass Manufacturer guidanceAluminium (6063 T6) / Glass |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceEPD Available On Request. |
Recyclability | 100 Manufacturer guidanceUp to 100% Glass / 100% Aluminium. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 70 % Manufacturer guidance17–28% for glass. 75% for aluminium. Expected recycled content for Hydro 2.0. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 1 |