NBS Source
I'm a manufacturer

FireEco Ei30 Single Glazed Timber Framed Fire Rated Glass Partition System

Verified by manufacturer 14 days ago

Radii Third party certifications:
  • ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

    ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

    Certificate type

Single glazed fire rated timber framed partition system.

Jump to:
+44 (0)20 7952 4830 Website

Application

All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.

Description

Single glazed fire rated timber framed partition system. Part of a range of single or double glazed partition systems with fire insulation of Ei30 or Ei60 (other formats specified separately).


Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.

General information

Color

Other

Guidance for specification option:

Paint colour/ gloss level to be determined by specifier.

Finish

Natural

Primed

Painted

Material

Timber

Guidance for specification option:

Hardwood timber ≥640 kg/m³.

Glass

Shape

-

Manufacturer guidance

To suit project requirements; consult manufacturer for further details.

Warranty description

-

Manufacturer guidance

Dealt with on a project specific basis as part of the O&M process; consult manufacturer for details.


Uniclass

Pr_25_71_57_60 Partition panelsPrimary
Ss_25_12_65_65 Panel partition systems

CAWS

K30/130 Relocatable partition system

K30/10 Relocatable partition system

Product range

Fire Rated Systems / FireEco

Specification data - Partition panels

Third party accreditation

ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.

Guidance for specification option:

EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more).

Unit size

-

Thickness

95 mm.

Partition height (nominal)

-

Manufacturer guidance

3000 mm maximum; consult with manufacturer to ensure compliance with certification.

Width (nominal)

-

Manufacturer guidance

Restricted minimum and maximum widths - consult with manufacturer to ensure compliance with certification.

Deflection allowance (maximum)

-

Floor

-

Manufacturer guidance

Consult with manufacturer for system weight.


Verticals

50 mm deep x 95 mm wide.

Panel partition type

Frameless glass - centre glazed.

Framing, junctions, corners

50 mm deep x 95 mm wide.

Manufacturer guidance

Corners: Solid post 95 x 95 mm.

Joint treatment

-

Type

Butt jointed glazing; single glazed.

Guidance for specification option:

Consult with manufacturer to ensure compliance with test/assessment data.


Finish and colour

Coloured silicone.

Guidance for specification option:

Consult manufacturer and insert requirements.

Glazed panels

-

Type

Single centre glazed: 17 mm annealed multi-laminate fire glass.

Guidance for specification option:

Consult with manufacturer to ensure compliance with test/assessment data.


Door arrangement

-

Type

44 mm timber, single leaf door, single action.

44 mm timber, unequal leaf doors, single action.

44 mm timber, double leaf doors, single action.

Door frames

Stand alone doorset 65 mm deep x 95 mm wide.

With side or fanlight glazing 115 mm deep x 95 mm wide.

Door leafs

-

Type

Halspan 44 mm Prima Core(IFCA/06166).

Halspan 44 mm Optima Core(PAR/1034/01A:C01).

Falcon 44 mm Streboard Core (IFCA/08037).

Vision panels

Required.

Guidance for specification option:

Restricted to sizes within fire certification - consult with manufacturer and insert requirements.

Not required.

Ceiling

-

Type

-

Manufacturer guidance

Fire rated construction - consult with manufacturer for interface detail and insert requirements.

Method of support

-

Manufacturer guidance

Consult manufacturer for support detail and insert requirements.


Perimeters, skirtings, sills

50 mm deep x 95 mm wide.

Hardware

-

Manufacturer guidance

Consult manufacturer and insert requirements.


Seals

Intumescent silicone; Fire rated Solar PVC-U translucent ‘H’ joint.

Cable management and outlets

-

Manufacturer guidance

Consult manufacturer and insert requirements.


Other features

-

Manufacturer guidance

Consult manufacturer and insert requirements.


Manifestation

Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost.

Guidance for specification option:

Insert requirements.


Artwork and custom manifestation to client design.

Guidance for specification option:

Insert requirements.


Manufacturer guidance

To architects choice and in accordance with the requirements of Approved Document K.


StrengthGrade

-

Manufacturer guidance

Consult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm.


For glass load resistance criteria;

  • BS 5234 not applied to “all glass partition screens”.
  • Nominal line load criteria of “short-term impact load” utilised.
  • 0.36 kN/m applied as linear load at 1100 mm above FFL.
  • Glass deflection limited to L/65 or 25 mm, whichever is less under load.
  • Maximum deflection and stress in accordance with the glass performance requirements of EN 572/ EN 12150/ EN 12543/ EN 14179 (where heat soaked).


Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:

  • 0.36 kN/m (default load).
  • 0.74 kN/m.
  • 1.5 kN/m.


BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm.

Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings).

Structural glass based on line-load and attendant UDL + point load, insert as required:

  • 0.74 kN/m.
  • 1.5 kN/m.
  • 3.0 kN/m.


Acoustic performance

39 dB Rw.

Fire insulation

Ei30 (30/30 Integrity and Insulation)

Partition

Frameless glass - single centre glazed.

Fasteners

To manufacturer's specification, type, length and frequency to suit substrates.

Joint treatment

Butt jointed glazing.

Samples required

-

Manufacturer guidance

Consult with manufacturer.


Finish/ Colour

Natural timber finish.

Factory primed.

Wet spray to match RAL colour.

Guidance for specification option:

Insert requirements, including gloss levels.

Sustainability data

Contains Red List materials

No

Guidance for specification option:

No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product.

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Timber

Guidance for specification option:

Hardwood timber ≥640 kg/m³.

Glass

Recyclability

100%

Guidance for specification option:

Timber and glass.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

28 %

Guidance for specification option:

17–28% for glass.


Third party certifications

ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report

FireEco SG Ei30 Hardwood Timber Partition System Acoustic Certificate

Literature

Radii Client Support & Aftercare Flyer

Radii Client Support & Aftercare Flyer