Bespoke light gauge steel framing (LGSF) structure, comprising selected Remagin external (EXT-020), internal (INT-001) and separating walls (SWR-015), along with stairs, floor and roof options.
Steel framed panelised construction for low and medium rise projects up to 15-storeys. Suitable for:
Bespoke light gauge steel framing (LGSF) structure, comprising selected Remagin external (EXT-020), internal (INT-001) and separating walls (SWR-015), along with stairs, floor and roof options.
Light gauge steel frame structural solutions for low and medium rise projects up to 15 storeys:
Remagin's light to medium-duty steel frame solutions are perfect for low and mid-rise developments up to fifteen storeys high. They especially excel in urban spaces with limited room, and their pre-assembled nature means construction programmes can be accelerated significantly. Built by precision manufacturing in factory conditions, and rapid to assemble on site, Remagin’s light steel framing systems offer superior safety and comfort levels, as well as high energy performance levels, for residents.
Features and benefits:
Walls:
Please contact Remagin for full details on wall build-ups.
Stairs:
Standard 1200 mm-wide option:
Stairs: 1500 mm-wide option:
Intermediate floors:
Roof, concrete option:
Roof:
Color | Silver Pink Guidance for specification option: Unfinished Siniat Fire Board. |
Finish | Galvanized Smooth Guidance for specification option: Unfinished Siniat Fire Board. |
Material | Steel Concrete Gypsum |
Shape | Rectangle Trapezoid Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | B15/130 Light-gauge steel frame |
Classification data | |
System performance | Guidance for specification option: Insert requirements. |
Structure type | |
Floors | SigDeck100 composite floor system. Guidance for specification option:
Manufacturer guidanceTrapezoidal deck available in 0.8, 0.9, 1.1 and 1.4 mm gauges; SigDeck can be designed for up to two-hour fire resistance with varying load types and spans. Consult manufacturer's literature for performance details and insert requirements. |
Framed wall structure | Light-gauge steel frame utilizing 100 x 53 x 1.2 mm C studs (100SN12) at 600 mm c/c throughout external, internal and separating walls. Separating walls only: Siniat RDB3000 resilient bars at 400 mm c/c. Guidance for specification option: See Linings below for board/ panel details. Manufacturer guidanceNote that resilient bar centres can be increased to 600 mm if only REI60 is required for the wall systems; consult manufacturer for further details. |
Roof structure | Trapezoidal profile galvanized steel roof decking. Guidance for specification option: Supplied in double span lengths supported on LGSF purlins, purlins depths and section sizes to suit span requirements. Manufacturer guidanceConsult manufacturer for options and insert requirements. |
System completion | Guidance for specification option: Insert requirements or omit. |
Design | Guidance for specification option: Insert details (drawings, schedule or other) as required. |
Internal | Stairs: 1200 mm wide (standard). Guidance for specification option: Prefabricated steel stairs comprising, 1200 mm-wide, 3 mm-thick folded plate treads together with bonded 25 mm CP board with flat steel stringers, together with 180 mm-thick composite concrete metal deck half landings.
Consult manufacturer for details and insert requirements. Stairs: 1500 mm wide. Guidance for specification option: Prefabricated steel stairs comprising, 1500 mm-wide, 3 mm-thick folded plate treads together with bonded 25 mm CP board with flat steel stringers, together with 180 mm-thick composite concrete metal deck half landings. Consult manufacturer for details and insert requirements. Manufacturer guidanceOther tread options are available if required. |
Floor deck | Sigmat Sig-Deck. |
Walls | External: EXT-020, 217 mm-thick. Internal: INT-001, 160 mm-thick. Separating: SWR-015, 212 mm-thick. Guidance for specification option: External wall thickness includes minimum 75 mm mineral wool (55 kg/m³) insulation to cavity face of frame. Excluding this insulation wall thickness is approx. 143 mm. |
Linings | External walls (outer): 1 x 12.5 mm Siniat Weather Defence Board. External walls (inner): 2 x 15 mm Siniat Fire Board. Internal walls: 2 x 15 mm Siniat Fire Board to both sides. Separating walls: 2 x 15 mm Siniat Fire Board to both sides. |
Insulation | External walls: minimum 75 mm-thick mineral wool (~55 kg/m³) to cavity face of frame; 100 mm-thick mineral wool (~22 kg/m³) between linings. Internal walls: n/a. Separating walls: 50 mm-thick mineral wool (~22 kg/m³) between studs. |
Fixings | External wall lining (sheathing board): 25 mm Wet Area self-drilling screws. External wall lining (plasterboard): 25 and 42 mm self-drilling screws. Internal wall lining: 25 and 42 mm self-drilling screws. Separating wall lining: 25 and 42 mm self-tapping screws. Separating wall resilient bars: 12 mm wafer head self-tapping screws. Guidance for specification option:
|
Fire resistance | To EN 1365-1:2012, REI 90 (external/ internal/ separating walls). Guidance for specification option: External wall EXT-020: REI 90 (I→O) and REI 120 (O→I). Manufacturer guidanceConsult manufacturer for test data as required. |
Sound insulation | External walls, Rw(Ctr): 48 (-7) dB. Internal walls, Rw(Ctr): 50 (-7) dB. Separating walls, Rw(Ctr): 63 (-6) dB. Guidance for specification option: External wall figure estimated ±3 dB; excludes facade finishes. Internal wall figure estimated ±3 dB. |
Thermal performance | External walls: 0.21 W/m²K (excluding facade fixings or external cladding/ bracketry). |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Manufacturing plant location | |
Material | Steel Concrete Gypsum |
| Carbon dioxide equivalent | |
Carbon dioxide equivalent, as defined in BS EN 15804 Certified | |
Stage Normalised unit (kg CO₂ eq/kg) Declared unit (kg CO₂ eq/kg) Stage:A1–A3 ('Production stage') Normalised unit : 3.26 (kg CO₂ eq/kg) Declared unit : 3.26 | |
Recyclability | Steel is 100% recyclable. Guidance for specification option: The system is designed to be re-purposed. |
Expected Life | 60 year |