NBS Source
I'm a manufacturer

LandMark IV Robust Interlocking Rainscreen Cladding

Verified by manufacturer today

Fusion Facades Product certifications:
  • R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

    R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

    Certificate type

Our LandMark IV Robust Interlocking Rainscreen Cladding aluminium system is perfect for large panel formats up to 3800 x 590mm.

Jump to:
+44(0)1706751400 Website

Application

Rainscreen cladding with large format panels. LandMark Aluminium Rainscreen Cladding.

Description

Aluminium panel rainscreen cladding system with robust interlocking.

Features and benefits:

  • Panels manufactured in project-specific sizes to form either a multi panel build up or a full storey floor to floor height arrangement.
  • Independently tested to CWCT standards.
  • A multitude of finishes is available: polyester powder-coated, anodized etc.
  • Design service and support available.
  • Compatible with an extensive range of standard & project-specific architectural fabrications to suit wide-ranging applications.
  • Reaction to fire to EN 13501-1:2007+A1:2009, class A2-s1,d0 Anodised aluminium, PPC aluminium, Pre-coated aluminium. To EN 13501-1:2007+A1:2009, class A1 Stainless steel, Weathering steel, Copper alloy, Zinc.
  • Installation can be achieved either by utilising the manufacturer’s own helping hand secondary support or a proprietary system.
  • Fully adjustable and modifiable to suit any situation or condition.
  • Defined by BS 476 Part 4, aluminium alloys are non-combustible, Part 7 Surface Spread of Flame ‘Class 1’.
  • Defined by BS 476 Part 6, fire propagation ‘Class 0’.
  • Secret fix system.
  • Can be supplied curved, facetted or straight.
  • Special features such as fins or baguettes are easily incorporated.
  • Can accommodate localised building movement joints of 20 mm as standard, in addition to handling continuous thermal and settlement movements (but can be more if required).
  • When using a variety of facade finishes to divide up large flat areas, such as ceramic tiles, HPL, brick slips, etc., it may be preferable for the designer to use one standard support system throughout rather than a number of manufacturers’ own systems.
  • For large panel formats up to 3800 x 590 mm.

General information

Color

Silver

Other

Beige

Black

Blue

Show more

Finish

Powder-coated

Anodized

Other

Material

Aluminium

Shape

Rectangle

Other

Square

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

-

Manufacturer guidance

Consult the manufacturer depending on the specified finish and project location.

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Design of a rainscreen cladding system

System manufacturer

Fusion Facades Limited.

Thermal insulation

Guidance for specification option:

Consult manufacturer for options and insert u-value requirements to suit.

Breather membrane

-

Material

Guidance for specification option:

Insert material if the insulation manufacturer requires a breather membrane; otherwise omit.

Fasteners

Guidance for specification option:

Insert fastener type if a breather membrane is required; otherwise omit.

Secondary support structure

Manufacturer's standard helping hand system.

Guidance for specification option:

Consult manufacturer for details.

Other.

Guidance for specification option:

Insert requirements, proprietary system such as Nvelope, Hilti, Kladfix or Ash & Lacy.

Cavity fire barriers

-

Horizontal

Guidance for specification option:

Horizontal cavity barriers by others. As specified by a fire engineer, insert details.

Vertical

Guidance for specification option:

Vertical cavity barriers by others. As specified by a fire engineer, insert details.

Cladding panels

-

Material

LandMark IV robust interlocking panels, 1.5 mm-thick aluminium.
LandMark IV robust interlocking panels, 2.0 mm-thick aluminium.
LandMark IV robust interlocking panels, 3.0 mm-thick aluminium.
LandMark IV robust interlocking panels, 1.5 mm-thick stainless steel.
LandMark IV robust interlocking panels, 2.0 mm-thick stainless steel.
LandMark IV robust interlocking panels, 3.0 mm-thick stainless steel.

Manufacturer guidance

Panels sizes including overall thickness to be defined under Dimensions.

Panel joints

Labyrinth joints, interlocking.

Guidance for specification option:

Closed joints are recessed 20 mm to match the panel face. Other joint widths/ types are possible; please consult the manufacturer for details.

Reveals

Guidance for specification option:

Insert requirements or omit.

Where the reveal is less than 175 mm deep, continuous closer panels are used. For more information, please contact the manufacturer.

System accessories

Not required.
Louvres.

Guidance for specification option:

Consult manufacturer for details and insert requirements as appropriate.

Louvred doors.

Guidance for specification option:

Consult manufacturer for details and insert requirements as appropriate.

Secret doors.

Guidance for specification option:

Consult manufacturer for details and insert requirements as appropriate.

Perforated screens.

Guidance for specification option:

Consult manufacturer for details and insert requirements as appropriate.

FIns.

Guidance for specification option:

Consult manufacturer for details and insert requirements as appropriate.

Other.

Guidance for specification option:

Consult manufacturer for options and insert requirements or omit.

Panel finish

Anodized.

Guidance for specification option:

Aluminium panels only.

Polyester powder-coated.

Guidance for specification option:

Not available for weathering steel panels.

Other.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Not required.

Guidance for specification option:

Weathering steel only.

External aluminium cladding colour

Guidance for specification option:

Consult manufacturer for options depending on required finish and insert requirements. Refer to drawing or schedule for mixed-colour configurations.

Dimensions

Guidance for specification option:

Insert requirements or drawing reference, schedule etc. as required.

  • Panel thickness: 40–100 mm thick.
  • Panel sizes: Suitable for large panel formats up to 3800 x 590 mm.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Aluminium

A1-A3 (production stage)

Normalised unit

Declared unit

0 kg CO₂ eq/unit

Self-declared

Lower emissions

Recyclability

Bespoke product minimal reuse potential. 95% + recyclability

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

95 %

Product certifications

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

UK Fire Test Results

Literature

Fusion Facades Specifier Guide

Fusion Facades Specifier Guide

Case studies

Battersea Reach, Blocks H & J

Battersea Reach, Blocks H & J

Similar products from Fusion Facades

LandMark I Aluminium Secret Fix Rainscreen Cladding

LandMark I Aluminium Secret Fix Rainscreen Cladding

LandMark II Aluminium Recess Fixing Rainscreen Cladding

LandMark II Aluminium Recess Fixing Rainscreen Cladding

LandMark III Aluminium Interlocking Rainscreen Cladding

LandMark III Aluminium Interlocking Rainscreen Cladding