NBS Source
I'm a manufacturer
Compare variants

Hudevad P5 Horizontal - Radiator

Verified by manufacturer 3 days ago

Type 10 Radiator

Hudevad Radiator Design A/S Variant:
Third party certifications:
  • Independent sustainability assessment

    Independent sustainability assessment

    Certificate type

  • DoP

    DoP

    Certificate type

Wall or floor mounted radiator in steel with fixed casing and convectors.

Jump to:
+44 (0)24 7688 1200 Website

Application

Suitable choice for the interior of any room.

Description

Hudevad P5 Horizontal has a clean design and reliable output. A 2 mm thick front plate with the characteristic Hudevad edge makes is one of the main features of the P5. The deep models of the P5 Horizontal and all Lowline models have closed sides, welded steel top with a streamlined effect which allows the air to circulate for maximum efficiency.


Features and benefits:

  • Pre-treatment by degreasing and steel phosphating.
  • Powder coated in accordance with DIN 55900, EN 442.
  • Max operating pressure 10 bar in accordance with EN 442.
  • 2 mm steel casing according to EN 10051.
  • Steel panel (heating element) according to EN 442.

General information

Color

White

Guidance for specification option:

White RAL 9016 70% Gloss.

Other

Finish

Powder-coated

Material

Steel

Shape

Rectangle

Length

410 mm

420 mm

510 mm

520 mm

610 mm

Show more

Width

35 mm

62 mm

102 mm

160 mm

Height

320 mm

420 mm

520 mm

620 mm

720 mm

Show more

Warranty description

Ten year

Uniclass

Pr_70_60_36_73 RadiatorsPrimary

CAWS

T90/465 Radiators

T90/465 Radiators

Specification data - Radiators

Standards

To BS EN 442-1 and BS EN 442-2.

Radiator type

Single plain panel.

Guidance for specification option:

Type 10.

Output

Guidance for specification option:

Consult manufacturer and insert requirements.

Finish

Powder-coated.

Guidance for specification option:

In accordance with DIN 55900, EN 442.

Connections

Guidance for specification option:

Consult manufacturer and insert requirements.

Manufacturer guidance

All connections 1/2” standard (adapters available).

Accessories

Not required.

Feet.

Easy clean bracket.

Forced water.

Danfoss TRV head.

Guidance for specification option:

For tapping Code 11,12, 13,14,16 and 18.

Casing

To EN 10051, 2.00 mm steel.

Heating element

To EN 442, steel panel.

Colour

White RAL 9016, gloss 70.

Guidance for specification option:

Standard.

Other.

Guidance for specification option:

Can be painted in other colours. Insert requirements.

TestPressure

13 bar.

Operating pressure (maximum)

To EN 442, 10 bar.

Operating temperature

110°C.

Height

320 mm.

Guidance for specification option:

H1: 320 mm.

H2: 300 mm.

420 mm.

Guidance for specification option:

H1: 420 mm.

H2: 400 mm.

520 mm.

Guidance for specification option:

H1: 520 mm.

H2: 500 mm.

620 mm.

Guidance for specification option:

H1: 620 mm.

H2: 600 mm.

720 mm.

Guidance for specification option:

H1: 720 mm.

H2: 700 mm.

Show more

Manufacturer guidance

For height 200 mm, please see P5 Lowline.

Depth

35 mm.

Length

Guidance for specification option:

410—2020 mm.

Consult manufacturer and insert requirements.

Manufacturer guidance

Availability of lengths varies depending of chosen tapping configuration and height.

Tapping configuration

Tapping code 10.

Guidance for specification option:

Tapping type: ABCD (4 taps).

L1: 410—2010 mm (in 100 mm increments).

L2: 200—2000 mm (in 100 mm increments).

Tapping code 11.

Guidance for specification option:

Tapping type: FF built-in valve (6 tap right).

L1: 420—2020 mm (in 100 mm increments).

L2: 200—2000 mm (in 100 mm increments).

Danfoss TRV Head required.

Tapping code 13.

Guidance for specification option:

Tapping type: Center tap, right (8 taps).

L1: 420—2020 mm (in 100 mm increments).

L2: 200—2000 mm (in 100 mm increments).

Danfoss TRV Head required.

Tapping code 15.

Guidance for specification option:

Tapping type: E/F, no valve.

L1: 610—2010 mm (in 100 mm increments).

L2: 400—1800 mm (in 100 mm increments).

Tapping code 16.

Guidance for specification option:

Tapping type: E/F, with valve Right/Left.

L1: 610—2010 mm (in 100 mm increments).

L2: 400—1800 mm (in 100 mm increments).

Danfoss TRV Head required.

Show more

Manufacturer guidance

See manufacturers literature for more information.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

United Kingdom

Recyclability

Yes

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

99 %

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

Independent sustainability assessment

Independent sustainability assessment

Green Building Council Denmark

DoP

DoP

Hudevad P5 Horizontal Tapping Code 10- 14 DoP

DoP

DoP

Hudevad P5 Horizontal Tapping Code 15- 18 DoP

Literature

Hudevad P5 Horizontal

Hudevad P5 Horizontal

Case studies

New Sct. Hans Forensic Psychiatric Hospital

New Sct. Hans Forensic Psychiatric Hospital