Verified by manufacturer 3 days ago
Type 22 Radiator
Independent sustainability assessment
Certificate type
DoP
Certificate type
Wall or floor mounted radiator in steel with fixed casing and convectors.
Wall or floor mounted radiator.
Hudevad Fionia Lowline has a 2 mm thick front plate with the characteristic Hudevad edge, closed sides and fitted with a removable grille with angled slats, so the convectors inside can't be seen. The grille is recessed in the top of the radiator so it is flush with the radiator edge.
The grille can be supplied with a anti-tamper bracket, so it can´t be removed.
Features and benefits:
Color | White Guidance for specification option: White RAL 9016 70% Gloss. Other |
Finish | Powder-coated |
Material | Steel |
Shape | Rectangle |
Length | 1010 mm 1020 mm 1210 mm 1220 mm 1410 mm |
Width | 118 mm 176 mm 234 mm |
Height | 220 mm |
Warranty description | Ten year |
Uniclass | |
CAWS | T90/465 Radiators T90/465 Radiators |
Standards | To BS EN 442-1 and BS EN 442-2. |
Radiator type | Double panel double convector.Guidance for specification option: Type 22. |
Output | Guidance for specification option: Consult manufacturer and insert requirements. |
Finish | Powder-coated.Guidance for specification option: In accordance with DIN 55900, EN 442. |
Connections | Guidance for specification option: Consult manufacturer and insert requirements. Manufacturer guidanceAll connections 1/2” standard. |
Accessories | Not required.Anti-tamper bracket.Danfoss TRV Head.Guidance for specification option: Required for Tapping Code 11 and 12. |
Casing | To EN 10051, 2.00 mm steel. |
Heating element | To EN 442, steel panel. |
Grille | Powder-coated steel. |
Colour | White RAL 9016, gloss 70. Guidance for specification option: Standard. Other. Guidance for specification option: Can be painted in other colours. Insert requirements. |
TestPressure | 13 bar. |
Operating pressure (maximum) | To EN 442, 10 bar. |
Operating temperature | 110°C. |
Height | 220 mm. |
Depth | 118 mm. |
Length | 1010 mm. Guidance for specification option: L1: 1010 mm. L2: 1000 mm. 1020 mm. Guidance for specification option: L1: 1020 mm. L2: 1000 mm. 1210 mm. Guidance for specification option: L1: 1210 mm. L2: 1200 mm. 1220 mm. Guidance for specification option: L1: 1220 mm. L2: 1200 mm. 1410 mm. Guidance for specification option: L1: 1410 mm. L2: 1400 mm. Manufacturer guidanceAvailability of lengths varies depending of chosen tapping configuration. |
Tapping configuration | Tapping code 10. Guidance for specification option: Tapping type: ABCD (4 taps). L1: 1010—2010 mm (in 100 mm increments). L2: 1000—2000 mm (in 100 mm increments). Tapping code 11. Guidance for specification option: Tapping type: FF built-in valve (6 tap right). L1: 1020—2020 mm (in 100 mm increments). L2: 1000—2000 mm (in 100 mm increments). Danfoss TRV Head required. Tapping code 12. Guidance for specification option: Tapping type: EE built-in valve (6 tap left). L1: 1020—2020 mm (in 100 mm increments). L2: 1000—2000 mm (in 100 mm increments). Danfoss TRV Head required. Tapping code 15. Guidance for specification option: Tapping type: E/F, no valve. L1: 1210—2010 mm (in 100 mm increments). L2: 1000—2000 mm (in 100 mm increments). Manufacturer guidanceSee manufacturers literature for more information. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Recyclability | Yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 99 % |
Platform | Compatible | Version |
---|---|---|
- | 1 |