Verified by manufacturer 4 months ago
A two-component polyamide adduct cured high build epoxy paint.
An intermediate or finishing coat in epoxy systems in atmospheric exposure.
To Specify a full Intumescent Fire Protection Coating System C1-C4 (Primer + Intumescent + Topcoat) click on the link below and add to your Chorus Specification:
To Specify a full Anti-Corrosion System C1-C5 (No Intumescent Fire Protection) (Primer + Topcoat) click on the link below and add to your Chorus Specification :
For further advice on Specifications please contact Ian Morton at iam@hempel.com
Hempadur MIO 47950
A two-component polyamide adduct cured, high build epoxy paint which combines a relatively high volume solids content with a short drying time.
Features and benefits:
Product compatibility:
Drying time:
Determined for dry film thickness 125 micron (4.9 mils) at standard conditions. Indicative values at 20ºC; Hard dry: 120 minutes.
Color | Grey Manufacturer guidance12130* / (MIO) Grey. |
Finish | Semi-gloss |
Material | Epoxy |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | G10/650 Site painting G10/640 Shop painting G10/660 Shop plus site painting G10/635 Thermally sprayed zinc coating plus site-applied G10/630 Galvanizing plus site-applied G12/330 Proprietary metal members M60/18 Special coating M60/195 Special coating M60/175 Protective coating G12/30 Proprietary |
Colour | Grey.Manufacturer guidance12130* / (MIO) Grey. |
Volume solids | 76 ± 2%. |
Flash point | 24 °C (75.2 °F). |
Fully cured | 7 days 20°C (68°F). |
VOC content | 251 g/L (2.1 lbs/US gallon). |
Specific gravity | 1.2 kg/L (10 lbs/US gallon). |
Standard | NR/L3/CIV/039. Manufacturer guidanceApproved according to Network Rail spec NR/L3/CIV/039. |