NBS Source
I'm a manufacturer

H-BAU ISOMUR® PLUS Wall Base Insulation

Verified by manufacturer 3 months ago

J & P Building Systems Third party certifications:
  • European Technical Approval (ETA)

    European Technical Approval (ETA)

    Certificate type

Wall base thermal insulation system.

Jump to:
+44 (0)1844 215 200 Website

Application

To provide a thermal break between the base of an internal wall and its foundation.

Description

Designed to create a thermal break between the base of an internal wall and its foundation.


The H-BAU ISOMUR® PLUS system replaces the bottom course of internal masonry to thermally insulate the internal walls and reduce the risk of heat loss, condensation and mould growth.


If the foundation of the building is not insulated, the internal walls built on top of it will create a breach in the thermal envelope of the building.


Features and benefits:

  • Thermally insulates internal walls from the foundation.
  • Reduces risk of heat loss, condensation and mould growth.
  • Available in a wide range of dimensions.

General information

Color

Grey

Material

Concrete

Polystyrene

Shape

Rectangle

Length

600 mm

Width

115 mm

150 mm

175 mm

200 mm

240 mm

Show more

Height

113 mm

Uniclass

Pr_20_93_52_48 Loadbearing thermal break unitsPrimary

CAWS

F30/165 Gratings/ ventilators in internal walling

Specification data - Loadbearing thermal break units

Dimensions (nominal)

-

Width

115 mm.

150 mm.

175 mm.

200 mm.

240 mm.

300 mm.

Height

113 mm.

Fire resistance

To DIN 4102-3:1977-09.

Guidance for specification option:

Fire Behaviour of Building Materials and Building Components.

ThermalConductivity

0.245 W/mK.

Density

To DIN 1053-1.

Third party certifications

European Technical Approval (ETA)

European Technical Approval (ETA)

European Technical Assessment For ISOMUR PLUS - ETA-18/1063

Literature

ISOMUR Plus Wall Base Insulation

ISOMUR Plus Wall Base Insulation