R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041
Certificate type
EPD
Certificate type
R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041
Certificate type
Carbon steel standing seam facade cladding system.
For use in fully supported facade applications.
GreenCoat ® PLX Colour Coated Steel Standing/ Angle Seam for use in fully supported facade applications.
The single locked standing seam is formed by interlocking the sides of adjoining panels by single welting the top of the upstand of the seam.
The final fold is turned parallel to the cladding surface. This means it is less watertight than the double lock standing seam.
The angled standing seam is used for vertical cladding where a more definitive visual line is required and is not recommended for slopes below 35°.
Features and benefits:
Typical system build up:
Installation:
A list of recommended installers is available on request.
Email: sales@metalsolutions.uk.com
Color | Black Grey Silver White Gold |
Finish | Coated |
Material | Carbon steel |
Shape | Other Guidance for specification option: Long strip standing seam. |
Length | Bespoke Manufacturer guidanceRecommended: 6 m horizontal, 4 m vertical (maximum). |
Width | Bespoke Manufacturer guidance430 mm and 530 mm standard, bespoke width possible. |
Height | Bespoke Manufacturer guidance25 mm seam height. |
Warranty description | 50 year Guidance for specification option: Technical guarantee. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
Classification data | |
System performance | Manufacturer guidanceFully supported standing seam facade cladding. Consult manufacturer for details and insert requirements. |
System manufacturer | Metal Solutions Limited. |
Membrane | Envirotect Class B-s1,d0 fire walling membrane. |
Insulation | Manufacturer guidanceTraditional angled seam cladding does not have any specific requirement with regard to the insulation. Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency. An insulation used as a directly supporting substrate must have a minimum compression strength of 50 kPa (0.5 kg/cm²) with deformation limited to a maximum of 10%. The insulation must also be dimensionally stable up to 100C. All insulation must be kept dry and protected prior to metal covering being laid. |
Air and vapour control layer | Manufacturer guidanceVapour Barrier membranes must comply with EN 13859-2 must also be CE compliant. For fully supported metal cladding the VB must have a minimum water vapour resistance of 4000 MNs/g and comply to BS SO 12572. The VB must have a resistance against a supported column of water 2 m high for a period of 15 minutes to comply with DIN EN 20811. All wall cladding must have a vapour barrier regardless of being ventilated, unventilated cold or warm in design. The VB must be positioned below the insulation, or for vertical cladding, behind the insulation and on the warm side of the construction. |
Carrier | As design. |
Substrate | 18 mm plywood exterior grade. Guidance for specification option: The European Standard is EN 636-3 - for use in exterior conditions including liquid, water or water vapour in damp but ventilated locations. Service Class 3 in Euro Code 5 covers plywood to be used in climate conditions leading to a higher moisture content than in service class 2. The minimum board thickness must be 18 mm (or layers of thinner boards that combine to achieve the minimum 18 mm thickness for curved coverings). The plywood face laminate must be free of knots and defects and should as a minimum be "good one side". Shuttering ply is not suitable. 18 mm OSB-3 or better (oriented strand board). Guidance for specification option: Also known as sterling board, has been developed over the past 20 years and is formed by layered flakes of wood in specific orientation. Its wooden strips are compressed and bonded together with wax and resin adhesive. It is comparatively cost effective and therefore has been increasingly used as a substrate for Cladding systems. However, care must be exercised when used as a substrate under traditional metal Cladding and should be protected from moisture during construction. It is advised that screw fixings are used to ensure good pull-out values. 24 mm timber or sarking board decking. Guidance for specification option: It complies with 8S5268: Part 2 (strength class SC3), or EN 1611-1:1999 (sawn timber normally with a maximum moisture content of 22%). There are some woods which are not compatible with Cladding metals, due to high acid content. UK recommended practice is a range of 18 mm to 25 mm thickness, in widths of 100 mm to 125 mm and laid with 3–5 mm gaps between the boards parallel to the eaves. In some cases, because of the nature of the building's structure, a diagonal boarding layout is used. It is particularly important to note that timber protectives, preservatives and adhesives used in plywood board construction can react with the cladding metal and if applicable, suitable separation layers must be used. Rigid insulation. Guidance for specification option: Insulation must be structurally self-supporting or supported when installed so that it will not sag and form unvented voids or cause loss of thermal efficiency. An insulation used as a directly supporting substrate must have a minimum compression strength of 50 kPa (0.5 kg/cm²) with deformation limited to a maximum of 10%. The insulation must also be dimensionally stable up to 100C. Warm roof fixings including stainless toothed plate and sliding clip, plastic peg and fixing screws are used in conjunction with an insulated deck. Composite panel. Guidance for specification option: The composite panel is constructed from factory produced interlocking steel or aluminium panels, encasing an insulation core (PIR or other). The panels are laid across the wall supporting rafters or rails. The interlocking joints must be sealed with gaskets or sealant and taped according to the manufacturer's recommendations, with sealed metal closures to hips ridges, verges, eaves and penetrations. The total area and abutments must be sealed airtight. 0.7 mm thick outer face is recommended. This type of construction gives a good vapour sealed substrate and can be quickly constructed. Non-combustibles. Guidance for specification option: Alternative non-combustible supporting substrates, such as metal profiled sheets and fire rated sheathing boards are now commonplace due to changes in building regulations. These are a direct substitute for plywood or similar and should be evaluated based on their pull-out values. When a metal profiled sheet is used, fixings must be rivets or self-drilling screws. Metal profile deck. Manufacturer guidanceIn depth choice of base substrates, can be advised by Metal Solutions technical team. |
Cavity barriers | |
Horizontal | Manufacturer guidanceTo architects’ specification. Insert requirements. |
Vertical | Manufacturer guidanceTo architects’ specification. Insert requirements. |
Sheet underlay | |
Material | ISO-Mat Pro® underlay. Guidance for specification option: Recommended for cladding applications. Envirotect Class B-s1,d0 Fire Walling Membrane Guidance for specification option: For use when a non-combustible option is required. Manufacturer guidanceThe breather membrane must comply with EN 13859-2 for walls and must also be CE compliant. The breather membrane must be fully supported, lapped and sealed and then further sealed to all surrounding abutments and surface penetrations. |
Fasteners | 25 mm fixed clips, RFC-25, breather membrane. 38 mm fixed clips, SM-EFK-38, breather membrane. 25 mm sliding clips, RSC-25, breather membrane. 38 mm sliding clips, SM-ESE-38, breather membrane. |
Timber cores for batten roll joints | |
Fasteners to substrate | Stainless steel fixed and sliding clips. |
Carbon steel | Carbon steel sheets. |
Vertical joints | |
Form | Standing seam joints. |
Fasteners to substrate | Timber - stainless screw - SPT-R-S-4.3x20-RS. Timber - annular ringshank nail - RSN-SS25. Metal - stainless screw - SX2-D9-4.8x22 or DS3-SS-SF-4.8x16. |
Cross joints | |
Form | Single lock cross welt 18 mm. |
Fasteners | Manufacturer guidanceInsert requirements. |
Head detail | |
Form | Standard head flashing detail. |
Bottom edge detail | |
Form | Standard bottom eave flashings. |
System accessories | Not required. Flashings. Guidance for specification option: All associated flashings to match can be fabricated from coil by Metal Solutions Ltd as per typical details and industry standards. Rainwater goods. Guidance for specification option: Associated rainwater goods in various sizes and profiles are available in the same material. Consult manufacturer and insert requirements. |
System completion | Operation and maintenance manual. |
Colour/ Finish | GreenCoat PLX Pural BT - Nordic Night Black. GreenCoat PLX Pural BT - Mountain Grey. GreenCoat PLX Pural BT - Anthracite Grey. GreenCoat PLX Pural BT - Metallic Dark Silver. GreenCoat PLX Pural BT - Metallic Silver. GreenCoat PLX Pural BT - Quarry Grey. GreenCoat PLX Pural BT - Snow White. GreenCoat PLX Pural BT - Metallic Gold. GreenCoat PLX Pural BT - Metallic Copper. GreenCoat PLX Pural BT - Chestnut Brown. GreenCoat PLX Pural BT - Cottage Red. GreenCoat PLX Pural BT - Tile Red. GreenCoat PLX Pural BT - Leaf Green. GreenCoat PLX Pural BT - Silver Fir Green. GreenCoat PLX Pro BT - Nordic Night Black. GreenCoat PLX Pro BT - Mountain Grey. GreenCoat PLX Pro BT - Anthracite Grey. GreenCoat PLX Pro BT - Metallic Sterling. Bespoke. Guidance for specification option: Bespoke colours available on request. Consult manufacturer for details and insert requirements. |
Size and profile | Manufacturer guidanceOptimised panel widths are based on available coil widths (some colours will vary). Cladding: 530 mm wide (x 6 metres long maximum). Consult manufacturer and insert requirements. |
Weight | 0.6 mm material weight 4.62 kg/m². Guidance for specification option: System weight dependent on seam centres. |
Reaction to fire | To EN 13501-1, A1-s1,d0. |
Contains Red List materials | No |
Country of material origin | Sweden |
Country of product manufacture | United Kingdom |
Material | Carbon steel |
A1–A3 ('Production stage') | Embodied carbon as defined in BS EN 15804 |
Normalized unit | 2.63 kg CO₂ eq/kg |
Declared unit | 2.63 kg CO₂ eq/kg Certified |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % |
Expected Life | 50 year |
SSAB - 2019 UK GreenCoat story
SSAB EPD GreenCoat - color coated steel sheets and coils
SSAB - GreenCoat Colours
SSAB-GreenCoat-EPD-Color-Coated-Steel-Sheets
SSAB - GreenCoat-European guarantee
SSAB - GreenCoat Inspection and maintenance
SSAB - GreenCoat PLX Pural BT
SSAB PX29354-1 EN 13501-1 Emea AB