NBS Source
List your products

GGL manually operated, centre-pivot roof window, with GIL sloping fixed windows below, combination installation

Third party certifications:
  • QA Certificate

    Certificate type

VELUX Company Ltd

Manually operated, centre pivot roof window with additional lower fixed element for combination installations on roof pitches between 15–90°.

Jump to:
+44 (0)1592 778225 www.velux.co.uk
Description

Manually operated, centre pivot roof window with additional lower fixed element for combination installations on roof pitches between 15–90°.

Fixed elements are installed in combination side by side to create panoramic views. The fixed window is installed directly below the roof window.

Combination flashings are modular meaning there is no limit to the overall size of the group, but the minimum distance between windows side by side is 100 mm.

Ventilation, exterior maintenance and cleaning is via the roof window.

Features:

  • Convenient operation – even with furniture placed beneath the window.
  • Easy to open and quick to close with the top control bar.
  • Additional fixed elements beneath offer a great view while standing and when seated.

Operation:

  • One pull of top control bar allows background ventilation whilst the window remains securely closed. One further pull opens the window.
  • Rotates 180° and locks in place for ease of cleaning of the outer pane.

Warranty:

  • Ten-year guarantee for windows and panes.
  • Three-year guarantee for electrical items and blinds.

General information
Features

Convenient operation – even with furniture placed beneath the window

Easy to open and quick to close with the top control bar

Additional fixed elements beneath offer a great view while standing and when seated

Uniclass 2015
Wood frame roof window units (Pr_30_59_98_97)Primary
Specification data - Wood frame roof window units
Product Reference

GGL manually operated, centre-pivot roof window, with GIL sloping fixed windows below, combination installation

Roof pitch

Insert requirements.

Number of roof windows

Insert requirements.

Number of fixed lights

Insert requirements.

Distance between side frames

100 mm

Standard frame gap.

120 mm

140 mm

160 mm

Windows -
Roof window code

GGL MK04

Standard size 780 mm wide x 978 mm high; effective daylight area 0.47 m².

GGL MK06

Standard size 780 mm wide x 1178 mm high; effective daylight area 0.59 m².

GGL MK08

Standard size 780 mm wide x 1398 mm high; effective daylight area 0.72 m².

GGL PK08

Standard size 942 mm wide x 1398 mm high; effective daylight area 0.92 m².

GGL PK10

Standard size 942 mm wide x 1600 mm high; effective daylight area 1.07 m².

GGL SK06

Standard size 1140 mm wide x 1178 mm high; effective daylight area 0.95 m².

GGL UK04

Standard size 1340 mm wide x 978 mm high; effective daylight area 0.91 m².

GGL UK08

Standard size 1340 mm wide x 1398 mm high; effective daylight area 1.40 m².

GGL MK10

Non-standard size 780 mm wide x 1600 mm high; effective daylight area 0.84 m².

GGL MK12

Non-standard size 780 mm wide x 1800 mm high; effective daylight area 0.96 m².

GGL PK25

Non-standard size 942 mm wide x 550 mm high; effective daylight area 0.27 m².

GGL PK04

Non-standard size 942 mm wide x 978 mm high; effective daylight area 0.60 m².

GGL PK06

Non-standard size 942 mm wide x 1178 mm high; effective daylight area 0.75 m².

GGL SK01

Non-standard size 1140 mm wide x 698 mm high; effective daylight area 0.48 m².

GGL SK08

Non-standard size 1140 mm wide x 1398 mm high; effective daylight area 1.16 m².

GGL SK10

Non-standard size 1140 mm wide x 1600 mm high; effective daylight area 1.35 m².

GGL UK10

Non-standard size 1340 mm wide x 1600 mm high; effective daylight area 1.63 m².

Fixed light code

GIL MK34

Standard size 780 mm wide x 920 mm high; effective daylight area 0.44 m².

GIL PK34

Standard size 942 mm wide x 920 mm high; effective daylight area 0.56 m².

GIL SK34

Non-standard size 1140 mm wide x 920 mm high; effective daylight area 0.70 m².

GIL UK34

Non-standard size 1340 mm wide x 920 mm high; effective daylight area 0.85 m².

Finish -
Internal frame and sash

White Painted – Code 2

Lacquered Natural Pine – Code 3

External cladding

Grey aluminium; colour reference NCS S-7500-N - Code 0

Untreated copper – Code 1

Titanium zinc – Code 3

Painted aluminium – Code 8, colour

Insert RAL or NCS colour reference.

Glazing

68

6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings.

66

6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings.

70

6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.

Blind -
Upper roof window

Not required

Blackout blind – Code DKL

Blackout energy blind – Code FHC

Duo blackout blind – Code DFD

Flying pleated blind – Code FHL

Roller blind – Code RFL

Roman blind – Code FHB

Solar powered blackout blind – Code DSL

Solar powered blackout energy blind – Code FSC

Solar powered pleated blind – Code FSL

Solar powered roller blind – Code RSL

Venetian blind – Code PAL

Colour

Not applicable

As schedule ___

Refer to VELUX Blinds and Shutters brochure for available colours and patterns.

Lower fixed window

Not required

Blackout blind – Code DKL

Blackout energy blind – Code FHC

Duo blackout blind – Code DFD

Roller blind – Code RFL

Roman blind – Code FHB

Solar powered blackout blind – Code DSL

Solar powered blackout energy blind – Code FSC

Solar powered pleated blind – Code FSL

Solar powered roller blind – Code RSL

Venetian blind – Code PAL

Colour

Not applicable

As centre-pivot

As schedule ___

Refer to VELUX Blinds and Shutters brochure for available colours and patterns.

Manual operation

Not required

Control rod and adaptor, Codes ZCT 200K and ZOZ 085

Energy efficient installation

Insulation Collar – Code BDX 2000

Not compatible with E*N and E*J flashings. Includes BFX.

Underfelt Collar - Code 1000

Vapour Barrier Collar – Code 0000

Flashing

EKL + ETL

For standard installation into slate up to 8 mm thick; roof pitch 15–90°

EKW + ETW

For standard installation into tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting.

EKN + ETN

For recessed installation into slate up to 8 mm thick; roof pitch 20–90°.

EKJ + ETJ

For recessed installation into tile up to 120 mm thick; roof pitch 20–90°.

ZWC

For standard installation where an on-site flashing is required; roof pitch 15–90°.

Accessories

None

Opening restrictor lock with key – Codes ZOZ 010KC S011

For upper roof window only.

Window lock – Code ZOZ 012K1

For upper roof window only.

Product Options

Glazing:

- Code 68:

  • Thermal performance (U-value): 1.1 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 66:

  • Thermal performance (U-value): 1.0 W/m²K.
  • Sound insulation (Rw): 37 dB.
  • Light Transmittance (Tv): 0.71.
  • Total solar energy transmittance (g): 0.52.

- Code 70:

  • Thermal performance (U-value): 1.3 W/m²K.
  • Sound insulation (Rw): 35 dB.
  • Light Transmittance (Tv): 0.68.
  • Total solar energy transmittance (g): 0.46.

Configuration:

The number of roof windows must be the same as the number of lower fixed windows; roof windows and lower fixed windows must be the same width.

Flashing:

Flashings are available in materials and finishes to match roof window cladding.

  • Code EKL + ETL: For standard installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate; Roof pitches from 15–90°.
  • Code EKW + ETW: For standard installation into flat and profiled roofing materials up to 120mm thick, including profiled sheeting and interlocking slates. Roof pitches from 15–90°.
  • Code EKN + ETN: For recessed installation into slate and flat roofing materials up to 8 mm thick. Not suitable for interlocking slate; Roof pitches from 15-90°.
  • Code EKJ + ETJ: For recessed installation into flat and profiled roof materials up to 90 mm thick, including profiled sheeting and interlocking slates; Roof pitches from 20-90°.
  • Code ZWC: Window profile set to be used in conjunction with on-site weathering for non-standard roofing materials. For further details please contact VELUX.

Third party certifications
  • CE marked: EN 14351-1:2006 + A2:2016
Similar products from VELUX Company Ltd