Decorative fireshield plywood panels.
Intended for internal use as structural component in dry conditions EN 636-1S:
Decorative fireshield plywood panels, modified through a ply-to-ply process which gives it fire-retardant properties. Complies with reaction to fire Class B as EN 3501 and is CE marked for structural use under attestation system 1.
Fire retardant classification:
Valid for the following end use conditions: Screwed to a standard fibre cement substrate, surface exposed.
Features and benefits:
Application:
Intended for internal use as structural component in dry conditions EN 636-1S:
- Typical installations:
Hotels, offices, public buildings, schools, court houses, hospitals, cinemas, discotheques.
Size[Size, Bespoke sizes available. Consult manufacturer for information] | - |
Uniclass 2015 | |
CAWS | G20/15 Plywood G20/310 Structural plywood K11/40 Plywood K11/815 Plywood N10/10 Purpose-made |
Product Reference | Garnica Fireshield, building |
Size (h x w) | 2440 x 1220 mm3100 x 1220 mm |
Thickness | 7–30 mm (4–6 mm as B s2 d0 only). Number of plies varies; consult manufacturer and insert requirements. |
Standard product features | Fire rating: - 6 mm and under: PEFC Fireshield FR Euro Class B-s2 d0, Spanish Poplar Plywood, E1, EN636-1NS, CE 4, EN 13986. - Over 6 mm: PEFC Fireshield FR Euro Class B-s1 d0, Spanish Poplar Plywood, E1, EN636-1NS, CE 4, EN 13986. Technical characteristics:
|
Product Options | Size: Bespoke sizes available. Consult manufacturer for information. |