Verified by manufacturer 8 days ago
UKAS
Certificate type
EN 13501-1 (Efectis)
Certificate type
CWCT Certificate
Certificate type
A1 non-combustible cassette cladding system; PVDF pre-coated solid aluminium cassette panels; CWCT Standards tested; 30-year warranty; 100% compliance with Building Regulations.
Drained and back-ventilated rainscreen cladding systems.
Futural joint fix system is a folded aluminium cassette panel system that utilizes fixings discretely placed within the panel joints, allowing for isolated and individual panel removal. It is a complete system solution featuring Futural Cladding panels, support rails and brackets, and colour matched fixings.
It is mechanically joint fixed, eliminating the need for adhesives, and panels can be independently replaced. It is a CWCT tested cladding system solution which is available in 2 and 3 mm aluminium and unlimited colour range.
Futural Cladding Panel
A1 non-combustible solid aluminium manufactured from marine grade aluminium and PVDF coatings; it is highly durable and impact resistant, yet available in unlimited colour range.
Compliant standards:
Features and benefits:
Color | Beige Black Blue Bronze Brown |
Finish | PVdF Gloss Matt Textured Smooth |
Material | Aluminium |
Shape | Rectangle Other |
Length | 2500 mm 3200 mm 4000 mm Bespoke |
Width | 1250 mm 1500 mm Bespoke |
Height | 2 mm 3 mm Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Thermal insulation | Manufacturer guidanceMineral wool insulation, supplied by others; insert requirements. |
Breather membrane | |
Material | Manufacturer guidanceFire rated breather membrane, supplied by others; insert requirements. |
Fasteners | Manufacturer guidanceSupplied by others; insert requirements. |
Secondary support structure | Futural aluminium support structure.Guidance for specification option: Insert requirements. |
Cavity fire barriers | |
Horizontal | Manufacturer guidanceSeek specialist information from specialist manufacturers and insert requirements. |
Vertical | Manufacturer guidanceSeek specialist information from specialist manufacturers and insert requirements. |
Cladding panels | |
Material | Futural aluminium cassette panels, 2 mm thick.Futural aluminium cassette panels, 3 mm thick.Manufacturer guidance
|
Panel joints | 20 mm standard closed joints in both vertical and horizontal directions. |
Reveals | Manufacturer guidanceInsert requirements or omit. |
System accessories | Manufacturer guidanceAll necessary accessories are available including, flashings, copings, bullnose and drainage channel. Insert requirements. |
Panel size | Manufacturer guidanceInsert requirements.
|
Panel | Guidance for specification option: Refer to Futural Colour Chart and insert requirements, or contact manufacturer for full list of colour options. Manufacturer guidancePanel colour. |
Surface finish | PVDF coating. |
Fire performance | Non-combustible. Guidance for specification option: All system components are A1/ A2 non-combustible. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Material | Aluminium |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 8.6 kg CO₂ eq/unit Self declared |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 99.5 % |