Fibre-reinforced calcium sulphate panel with tongue and grooving.
Application in areas of use with increased load requirements:
The dry hollow floor system FLOOR and more® power was developed especially for heavy duty areas. The hollow floor panels type power consist of fibre-reinforced calcium sulphate with optimized panel mixture. The gluing of the FLOOR and more® panels is made with a special tongue and grooving at the edges of the panels which are forming a closed load bearing layer. The substructure consists of height-adjustable zinc-coated steel pedestals from Lindner Group own production which form the necessary cavity for installations.
Features and benefits:
Color | White |
Finish | Other |
Material | Calcium sulphate Steel Guidance for specification option: Zinc-coated. |
Shape | Square |
Length | 600 mm |
Width | 600 mm |
Height | 40 mm |
Warranty description | 25 year |
Uniclass | |
CAWS | K41/130 Raised access floor K41/130 Raised access floor |
Product range |
Subfloor preparation | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Support structure type | Access floor pedestals. |
Pedestal fixings | Guidance for specification option: Consult manufacturer and insert requirements. |
Raised access floor surface | Raised access floor panels. |
Barriers in floor void | |
Fire barriers | Not required.Solid gypsum wall blocks.Guidance for specification option: Fire protection barriers made from solid gypsum wall blocks (min. 80 mm). |
Acoustic barriers | Not required.Foam mortar.Guidance for specification option: Sound protection barriers made from foam mortar (min. 100 mm). |
Plenum barriers | Not required.Coated chipboard panels.Guidance for specification option: Ventilation barriers made from coated chipboard panels. |
System accessories | Not required.Facings.Expansion joints.Electrical outlets.Cavity barriers.Air ventilation outlets.Revision openings.Bridging profiles.Reinforcement profiles. |
Calculated weighted sound reduction index (Rw) | 62–64 dB. Guidance for specification option: Values depending on additional measures. |
Fire resistance | To DIN 4102-2, F30, To BS EN 13501-2, REI 30; To BS EN 13501-2, REI 60. |
Impact sound reduction | 9–41 dB. Guidance for specification option: Values depending on additional measures. |
Pedestal height | Manufacturer guidance40–2000 mm. Insert requirements. |
Thickness | 30–40 mm. |
Load class | To EN 13213, 2-5. |
Breaking load | To EN 13213, 6—10 kN/ 3—5 kN. |
LoadSafetyFactor | To EN 13213, 2. |
Weight | 41–55 kg/m². |
Contains Red List materials | No |
Country of material origin | Germany |
Country of product manufacture | Germany |
Recyclability | yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 100 % |
Calcium sulphate raised access floor - NORTEC
Calcium sulphate raised access floor with factory applied parquet - NORTEC STONEline
FLOOR and more® G 30 x L / A
FLOOR and more® G 30 x L / A
FLOOR and more® G 40 x L / D - Hollow Floor with T&G Panels
Hollow Floor System with integrated heating - FLOOR and more® comfort
LIGNA S 38 ST x M - Particle Board Raised Access Floor
NORTEC L 30 x M - Raised Access Flooring
NORTEC L 38 ST x H - Calcium Sulfate Raised Access Floor Type
NORTEC L 38 x M - Raised Access Floor Panel