A BBA approved RubberBond FleeceBacked EPDM (Ethylene-Propylene Diene Monomer) waterproof membrane. A non-reinforced EPDM joined with a patented hot melt adhesive technology to a thick polyester fleece. Designed for fully adhered installations on warm or cold roof constructions. The system is available with a range of accessories, including Semi Cured Pressure Sensitive Tapes, Uncured Pressure Sensitive tapes, pipe seals, roof drains, moulded walkway pads and a range of roof edge products. Installation is carried out by trained independent Approved Local Contractors. The membrane is available in a slate grey finish.
Color | Grey |
Material | EPDM |
Shape | Rectangle |
Length | 12200 mm 15250 mm |
Width | 1500 mm 3050 mm |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering J42/120 Inverted roof covering J42/130 Cold deck roof covering J42/400 Waterproof membrane |
Product range |
Material | Ethylene propylene diene monomer (EPDM). |
Third-party certification | British Board of Agrément (BBA) Certificate. |
Thickness (minimum) | 2.54 mm. |
Colour | Black/ Grey. |
Accessories | 75mm Pressure sensitive secure tape. Guidance for specification option: For overlap seaming of sheets, alternatively use membrane with FAT. 150mm Pressure Sensitive Cover Strip. Guidance for specification option: Semi cured for butt joints of membrane and seaming to edge trims & adjoining materials. 225mm Pressure Sensitive Uncured tape. Guidance for specification option: For all detailing work. Pressure Sensitive Pipe seal. Guidance for specification option: To fit pipes 13–75 mm. Pressure Sensitive Pipe seal. Guidance for specification option: To fit pipes 13–75 mm. Pressure Sensitive Walkway pad. Guidance for specification option: Walkway Pad is designed to protect the membrane and give a non slip walkway in those areas exposed to repetitive foot traffic. HP-250 Primer. Guidance for specification option: To be used in conjunction with all Pressure Sensitive goods. Decking Adhesive. Guidance for specification option: Water Based Acrylic Adhesive (WBA) or Polyurethane Adhesive PU. Bonding Adhesive. Guidance for specification option: For adhering membrane at angle changes and upstands. Water Cut Off Mastic. Guidance for specification option: Used as a sealing agent between various membranes and applicable when membrane is being terminated using a compression type seal. Termination bars. Guidance for specification option: For mechanical termination to perimeter and upstands, used with Water Cut Off Mastic. HP Fasteners. Guidance for specification option: For mechanical fixing of insulation board, to be used with insulation plates 55mm - 175mm. Insulation Plates. Guidance for specification option: For fastening of insulation to be used with HP fasteners 75mm x 75mm. Angle roof drain. Guidance for specification option: Outlet opening 90 mm x 90 mm. Anti Back Up Drain. Guidance for specification option: 68mm. Top Drain. Guidance for specification option: 110mm outlet. Drip trim. Guidance for specification option: Refer to manufacturer for range of depths. Edge trim 75/ 150. Guidance for specification option: Refer to manufacturer for full colour range. Wall trim. Guidance for specification option: 25 x 100 x 3000 mm. RB Fasteners. Guidance for specification option: Available in 35 mm & 45mm for perimeter edge trim fastening. Paving Support discs. Guidance for specification option: used for patio roofs to support paving slabs & decking above the membrane surface. |
Roll size | 1.5 x 12.2 m. Guidance for specification option: With Factory Applied Tape (FAT). Optional (FAT) for faster seaming of membrane on site. 3.05 x 15.25 m. 3.05 m x 15.25 m. Guidance for specification option: With Factory Applied Tape (FAT). Optional (FAT) for faster seaming of membrane on site. |
Tensile strength (MPa) | 11.3 MPa. Guidance for specification option: Control. 11.6 MPa. Guidance for specification option: Heat aged. |
Elongation to break | 450%. Guidance for specification option: Control. 280%. Guidance for specification option: Heat aged. Manufacturer guidanceTo BS 903-A2. |
Water vapour permeability | 0.3 g/m²/day. Manufacturer guidanceTo BS 3177. |