Verified by manufacturer 13 days ago
ISO 9001 Quality Management
Certificate type
ISO 45001 Health and Safety Management
Certificate type
ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report
Certificate type
Double glazed fire rated steel framed partition system.
All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.
Double glazed fire rated steel framed partition system.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for our products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Guidance for specification option: Any RAL code. |
Finish | Powder-coated Guidance for specification option: Polyester powder-coated. |
Material | Steel Glass |
Shape | Manufacturer guidanceTo suit project requirements; consult manufacturer for further details. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third party accreditation | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | 108 mm.120 mm. |
Partition height (nominal) | Manufacturer guidanceConsult with manufacturer to ensure compliance with certification. |
Width (nominal) | Manufacturer guidanceConsult with manufacturer to ensure compliance with certification. |
Deflection allowance (maximum) | |
Head | Excluding deflection, excluding blinds: 60 mm-deep x 108-mm wide steel insulated channel.Excluding deflection, including blinds: 60 mm-deep x 120-mm wide steel insulated channel.±25 mm deflection, excluding blinds: 112 mm-deep x 141 mm-wide steel insulated two-part channel.±25 mm deflection, including blinds: 112 mm-deep x 155 mm-wide steel insulated two-part channel. |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Verticals | Excluding blinds: 60 mm-deep x 108 mm-wide steel insulated channel.Including blinds: 60 mm-deep x 120 mm-wide steel insulated channel.Manufacturer guidanceCorners: glass-to-glass joints. |
Panel partition type | Frameless glass - double glazed. |
Framing, junctions, corners | As Verticals. |
Joint treatment | |
Type | Butt jointed glazing; double glazed, fire-rated silicone joints.Guidance for specification option: Consult with manufacturer to ensure compliance with test/assessment data.
|
Finish and colour | Coloured silicone.Guidance for specification option: Consult manufacturer and insert requirements. |
Glazed panels | |
Type | Primary fire rated glazing: 17 mm annealed multi-laminate fire glass; Secondary sacrificial glazing: (10-21.5 mm)/ |
Integral blinds | Tilt / turn manual venetian blinds with blind control knob (fire risk side only).Guidance for specification option: Two panels maximum. Tilt / turn battery powered venetian blinds, remote control operation.Guidance for specification option: One white sensor battery pack per blind. Not required. |
Door arrangement | |
Type | Manufacturer guidanceConsult with manufacturer for details and insert requirements. |
Door frames | Manufacturer guidanceConsult with manufacturer for details and insert requirements. |
Door leafs | |
Type | Manufacturer guidanceConsult with manufacturer for details and insert requirements. |
Ceiling | |
Type | Manufacturer guidanceConsult manufacturer for interface detail and insert requirements. |
Method of support | Manufacturer guidanceConsult manufacturer for support detail and insert requirements. |
Perimeters, skirtings, sills | Excluding blinds: 60 mm-deep x 108 mm-wide steel insulated channel.Including blinds: 60 mm-deep x 120 mm-wide steel insulated channel.Manufacturer guidanceCorners: glass-to-glass joints. |
Hardware | Manufacturer guidanceConsult manufacturer and insert requirements. |
Seals | Primary fire glass: intumescent silicone. |
Other features | Manufacturer guidanceConsult manufacturer and insert requirements or leave blank. |
Product Reference | FireStop Ei60 Double Glazed Partition System |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | 47 dB Rw. Guidance for specification option: Excluding blinds. 48 dB Rw. Guidance for specification option: Excluding blinds. 49 dB Rw. Guidance for specification option: Including blinds. 50 dB Rw. Guidance for specification option: Including blinds. |
Fire insulation | Ei60 (60/60 integrity and insulation). |
Partition | Frameless glass - double glazed. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | Butt jointed glazing. |
Samples required | Manufacturer guidanceConsult with manufacturer. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Steel Glass |
Recyclability | 100% Guidance for specification option: Steel and glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17–28% for glass. 15–20% for steel. |
ISO 9001 Quality Management
ISO 9001 Certificate
ISO 45001 Health and Safety Management
ISO 45001 Certificate
ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report
Firestop Ei60 Multi-pane Double Glazed Partitioning System Acoustic Certificate
ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report
Firestop Ei60 Multi-pane Double Glazed Partitioning System with integral blind Acoustic Certificate
2D Demountable Relocatable Crosswall System - Modular Wall System
Align Flush Bonded Glazed Pivoting Door - Pivoting Door
FireClear100 Double Glazed Partition System
FireClear20 Single Glazed Partition System
FireClear54 Double Glazed Partition System
FireEco Ei30 Double Glazed Timber Framed Fire Rated Glass Partition System
FireEco Ei30 Single Glazed Timber Framed Fire Rated Glass Partition System
FireEco Ei60 Double Glazed Timber Framed Fire Rated Glass Partition System
FireEco Ei60 Single Glazed Timber Framed Fire Rated Glass Partition System
FirePro E120 Single Glazed Fire Rated Glass Partition System and Ei60 Fire Door