Description

Icopal Limited’s FireSmart TorchSafe M.A. is a mechanically fixed high performance single layer roof waterproofing system for use as an overlay for the renovation of existing roofs, or as a single layer for new build projects. FireSmart TorchSafe M.A. is a mechanically fixed high performance single layer roof waterproofing system for use as an overlay for the renovation of existing roofs, or as a single layer for new build projects. The 120 mm side overlap facilitates mechanical fixings which is then hot-air welded to form a waterproof seal.

General information

Uniclass 2015

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/115 Single layer reinforced bitumen membrane warm deck roof covering

J41/135 Single layer reinforced bitumen membrane cold deck roof covering

Specification data - Reinforced bitumen membrane warm roof covering systems

Product Reference

FireSmart TorchSafe M.A. Roofing System

Colour

Blue-grey

Brown

Charcoal

Green

Preparation

Not required

Anderson HT180 nailed layer

For timber boarded decks.

Anderson HT125 Taping Strip

For joints in ply/ OSB/ three decks.

Primer

Icopal S.A. Primer

Quick drying primer for self-adhesive membranes.

Vapour control layer

Not required

TorchSafe T.A. VCL - Sand

Heat-activated self-adhesive bituminous vapour control layer.

Insulation

Thermazone Roofboard

Top layer/ Capsheet

FireSmart TorchSafe M.A. single-layer membrane

Mechanically fastened single-layer membrane.

Flashings and detail work

-

Underlay

Icopal T.A. Detailing Underlay

Capsheet

FireSmart T.A. Detailing Capsheet

Accessories

None

Icopal Roofgard Lightning Conductor Pads

Icopal GRP Edge Trims

Icopal Roofgard Outlet

Icopal Roofgard Parapet Outlet

Icopal Roofgard Cowled Telescopic Vent

Icopal Roofgard Cable and Tube Duct

Product Options

Preparation:

Consult with Icopal Ltd for details of the preparation and priming of the intended roof structure and substrate and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips.

System build-up:

Consult Icopal Limited’s technical literature for details and guidance. Icopal Limited are also able to offer a design and specification service and it is recommended that they are consulted early in the design process.

Similar products from BMI Group UK Ltd

Anderson APP roofing system

Anderson HT System

Power Elastomeric system

Profiles Solo Roofing System

Profiles T.A. Warm Roofing System

Profiles T.A. Warm Roofing System

Profiles XL Warm System

Profiles XL Warm System

Total Torch Warm Deck Roofing System

Total Torch Warm Deck Roofing System