Fire-resisting (E120) acoustic roller shutters.
Suitable for any application where fire and sound compartmentation are required. Also suited to school kitchens in multi-function school halls where regulations dictate that fire resistance is necessary, but where a sound break is also essential to avoid disruption from the kitchen staff. Larger applications include exhibition halls where its incorporation allows sound and fire resistance at a fraction of the price of other door types such as movable walls.
Fire-resisting acoustic roller shutters, tested at the Department of Acoustics at Salford University and two Fire Test Laboratories. The door achieved a sound reduction of 25 dB Rw and fire-tested to EN 1634-1. It is rated E120-C0 in accordance with EN 13501-2, EN 14600, EN 15269-10 and EN 16034.
Features and benefits:
Applications:
Suitable for any application where fire and sound compartmentation are required. Also suited to school kitchens in multi-function school halls where regulations dictate that fire resistance is necessary, but where a sound break is also essential to avoid disruption from the kitchen staff. Larger applications include exhibition halls where its incorporation allows sound and fire resistance at a fraction of the price of other door types such as movable walls.
Size | |
Material | Galvanized steel Standard. Stainless steel, 1.4301 (304) grade Optional. Stainless steel, 1.4401 (316) grade Optional. |
Finish | Galvanized Standard. Polyester powder-coated, RAL Insert requirements. |
Uniclass 2015 | |
CAWS | L20/530 Sliding folding external doors L20/60 Doors L20/610 Roller shutters/ curtains |
Product Reference | Fireroll Acoustic E120 Roller ShuttersFireroll Acoustic E120 Roller Shutters Double Curtain32 dB sound reduction. |
Size | Bespoke; consult manufacturer for details and insert requirements. |
Material | Galvanized steelStandard. Stainless steel, 1.4301 (304) gradeOptional. Stainless steel, 1.4401 (316) gradeOptional. |
Finish | GalvanizedStandard. Polyester powder-coated, RALInsert requirements. |
Operation | 240 V, single-phase400 V, three-phase |
Accessories | NoneAudiovisual warningHeat/ smoke detectors |
Standard product features | Acoustic rating: When independently tested, the door achieved a weighted sound reduction index Rw of 25 dB (32 dB if a double curtain design is used). Weight: Approximately 50 kg per linear metre of width. |
Product Options | Finish: Galvanized as standard. A factory finish is available which comprises a white plastisol internal face (coil side) with the external face polyester powder-coated to a standard RAL colour. |