FireMaster® A1 ResQ-Window
Application

  • Escape routes incorporating doorways and corridors.
  • Lift openings and lobbies.
  • Areas where Fire Marshals and the Fire and Rescue Service may need to assess prior to entry.

Description

An electrically operated FireMaster® A1 ResQ-Window active fire curtain barrier assembly used to form a virtually continuous barrier as a fire separating element.

The barrier assemblies comprise a woven steel and glass fabric wound on to a steel roller, powered by an internal 24V dc electric motor, enclosed within a 1.2 mm Stainless Steel box. Within the main curtain assembly there are two vision panels.

A bottom bar is fitted to the bottom edge of the curtain providing tension to the curtain with sufficient weight for the curtain to ‘fail-safe by gravity’.

The 24V motor contains an electromagnetic brake to arrest motion of the curtain when in the open position.

The barrier assemblies have been tested to the requirements of BS EN 14600:2005 for ‘Durability of Self-Closing’ (500 cycles on primary power and an additional 50 cycles using back-up power; closing speed of 0.08m/s).

The barrier assemblies have been tested to the requirements of BS EN 1634-1:2014 for ‘Fire Resistance’ (120 minutes integrity).

The barrier assemblies have been tested to the requirements of BS EN 1634-1:2014 for ‘Radiant Heat Flux’ (30 minutes).

Features and benefits:

  • See through a deployed curtain as a means of escape.
  • Safely egress from lifts.
  • Suitable for lift lobby muster points.
  • First responder can clear a building faster.
  • First responder can see the presence of an occupant on the other side of a curtain.
  • First responder can see the presence of fire on the other side of a curtain.
  • First responder can see the presence of smoke on the other side of a curtain.

Operation:

Barrier assemblies commence movement upon initiation of alarm or power or system failure, and fully deploy to the fire operational position within the range of velocities of 0.06 m/s to 0.15 m/s using the unique VarioSpeed™ function.

Operating speeds are site adjustable without altering the bottom bar mass. Speeds may be dictated by those authorities having jurisdiction for ‘safety in use’ according to the location, nature or function of each unit.

In the event of a mains supply power failure, the curtain is retained in the open position for a pre-determined period (nominally 30 minutes), using battery back-up power. During this period, the Barrier assembly will deploy on receipt of a signal. At the end of the period, the Barrier assembly will deploy.

Fire resistance:

120 minutes' (two hours) integrity.

Period of radiation:

Greater than 30 minutes (for a radiation level measured below 15kW/m2)

Classification:

E120 EW30 C1.

Product certification, performance and/ or testing:

  • Complete barrier assemblies are certified by an independent accredited certification body operating to ISO/IEC 17065:2012.
  • Complete barrier assemblies have been tested for fire resistance to BS EN 1634-1. The Barrier assembly achieved 120 minutes Integrity and 30 minutes Radiation.

Approving standards:

The following standards apply to this product:

  • BS EN 1634-1:2014 + A1:2018, Fire resistance and smoke control tests for door, shutter and, openable window assemblies and elements of building hardware. Fire resistance tests for doors, shutters and openable windows
  • BS EN 1363-1:1999, Fire resistance tests – Part 1: General requirements
  • BS EN 1363-2:1999, Fire resistance tests – Part 2: Alternative and additional procedures
  • BS EN 13501-2:2007+A1, Fire classification of construction products and building elements. Classification using data from fire resistance tests, excluding ventilation services rating
  • BS EN 14600:2005, Doorsets and openable windows with fire resisting and/ or smoke control characteristics.
  • BS EN ISO 1716, Determination of the Heat of Combustion for Building Products
  • BS 6853 Annex B.2, Toxicity
  • BS 6853 Annex D.8.4, Methods for Measuring Smoke Density
  • BS EN 13823, Reaction to Fire Tests – Single Burning Item
  • BS EN 14184-1, Textiles – Determination of Formaldehyde – Part 1: Free and hydrolysed formaldehyde (water extraction method
  • HSG 248, Analysis of Material for the presence of Asbestos
  • BS EN ISO 9001:2015, Quality management system
  • BS EN ISO 14001:2015, Environmental management system

Application:

  • Escape routes incorporating doorways and corridors.
  • Lift openings and lobbies.
  • Areas where Fire Marshals and the Fire and Rescue Service may need to assess prior to entry.

General information

Material

The main curtain fabric type is EFP™ A1, which is a stainless steel wire reinforced glass fabric fire barrier. It has an area weight of 665g/m2 ± 10%

The curtain fabric offers dimensional stability and is non-combustible to BS EN 13501-1 + A1– Reaction to Fire

The fabric has passed testing to BS EN 1634-1, BS EN 1363-1 and BS EN 1362-2

The fabric has passed testing to BS 6853 Annex B.2 (Toxicity)

The fabric has passed testing to BS 6853 Annex D.8.4 (Methods for Measuring Smoke Density)

Show more

WarrantyDescription

One year

Uniclass 2015

Pr_30_59_84_73 Roller shuttersPrimary

CAWS

L20/610 Roller shutters/ curtains

Specification data - Roller shutters

Product Reference

FireMaster® A1 ResQ-Window

Standard

BS EN 1634-1, , BS EN 1363-1, BS EN 1363-2, BS EN 13501-2 +A1, BS EN 14600, BS EN ISO 1716, BS 6853, BS EN 13823, BS EN 14184-1, BS EN ISO 9001,BS EN ISO 14001

Opening sizes

Insert requirements.

Arrangement

Folded

Vertical

Accessories

None

Beam protection and obstruction warning

Beam obstruction detector with delay timer.

Emergency retract

Touch button retract facility.

Split drop delay

Partially deploys to pre-determined level to permit escape and initial smoke containment.

Visual alert system

Light warning system when mains or emergency power is available.

Voice warning

Audio or spoken multi-message facility when mains or emergency power is available.

Standard product features

Material:

The main curtain fabric type is EFP™ A1, which is a stainless steel wire reinforced glass fabric fire barrier. It has an area weight of 665g/m2 ± 10%.

The curtain fabric offers dimensional stability and is non-combustible to BS EN 13501-1 + A1– Reaction to Fire.

The fabric has passed testing to BS EN 1634-1, BS EN 1363-1 and BS EN 1362-2

The fabric has passed testing to BS 6853 Annex B.2 (Toxicity)

The fabric has passed testing to BS 6853 Annex D.8.4 (Methods for Measuring Smoke Density)

The fabric has passed testing to BS EN ISO 1716 (Determination of the Heat of Combustion for Building Products)

The fabric has passed testing to BS 476 part 6 (Fire Propagation Tests) and part 7 (Surface Spread of Flame Tests)

The fabric has passed testing to BS EN 13823 (Reaction to Fire Tests – Single Burning Item)

The fabric has passed testing to HSG 248 (Analysis of Material for the presence of Asbestos)

The fabric has passed testing to BS EN 14184-1 (Textiles – Determination of Formaldehyde – Part 1: Free and hydrolysed formaldehyde (water extraction method)

The fabric type used for the vision panels is ResQ-Window, which is a transparent material, manufactured from a High Silica base fabric with a diluted Silicone coating.

Warranty description:

One year.