Verified by manufacturer 15 days ago
Design .01 - Manual control and thermal
Hygiene requirements to VDI 6022
Certificate type
DoP
Certificate type
Certificate of Conformity
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
Certificate of constancy of performance
Certificate type
Type Examination Certificate
Certificate type
EPD
Certificate type
A manual or motorised fire damper for air conditioning ducts.
The fire dampers are suitable for installation in arbitrary
position in vertical and horizontal passages of fire separating constructions. The fire damper can be installed into:
Additional applications may be available, please reference product Technical Specifications for more detail.
A Fire Damper is used to prevent fire and reduce smoke spreading from one compartment to another through the air ductwork system which may penetrate fire separating walls and floors.
Features and benefits:
Color | Silver |
Finish | Galvanized |
Material | Steel Calcium silicate |
Shape | Circle |
Length | 300 mm 500 mm |
Width | 100 mm 125 mm 140 mm 150 mm 160 mm |
Height | 100 mm 125 mm 140 mm 150 mm 160 mm |
Uniclass | |
CAWS | U90/443 Dampers, fire/ smoke |
Standard | |
Fire dampers | To BS EN 15650:2010. |
Test | To BS EN 1366-2. |
Classification | To BS EN 13501-3. |
Aerodynamic performance | To BS EN 1751.Guidance for specification option: Damper body: Class C; Damper blade: Class 3. |
Arrangement | Single-blade. |
Classification | EIS90.EIS120.Manufacturer guidanceRefer to the manufacturer's literature for placement and installation details to achieve the required fire resistance values. |
Material | Zinc-coated steel. |
Fusible links | |
Fusing temperature | 72°C.Guidance for specification option: As standard. 104°C.147°C. |
Spare fusible links | Manufacturer guidanceInsert requirements or omit. |
Design | Round duct flange (P). Round duct flange, with installation brackets (PK). Spiro damper (SL). Spiro damper, with installation brackets (SK). |
Actuator | Mandik M. |
Diameter | 100 mm. 125 mm. 140 mm. 150 mm. 160 mm. |
Length | 300 mm. 500 mm. |
Duct connection | Mandik FFDM breakaway joint. Guidance for specification option: FFDM allows a breakaway connection between a duct and fire damper according to DW/145. The FFDM is a flanged breakaway joint with a plastic pad which will melt at 80°C, allowing the duct to break away from the damper and ensure the dampers integrity is maintained. Refer to FFDM – Technical specifications for options and insert requirements. Breakaway joint (supplied by others). Guidance for specification option: Insert requirements. |
Country of product manufacture | Czechia |
Material | Steel Calcium silicate |
Expected Life | 20 year |
Platform | Compatible | Version |
---|---|---|
- | 1 |
Hygiene requirements to VDI 6022
Hygienic assessment - Fire dampers
DoP
FDMR – Declaration of performance (UKCA)
DoP
FDMR – Declaration of performance (CE)
Certificate of Conformity
Declaration of conformity ATEX
UK Conformity Assessed (UKCA)
FDMR – Certificate (UKCA)
Certificate of constancy of performance
FDMR – Certificate (CE)
Type Examination Certificate
Certificate ATEX
EPD
Environmental Product Declaration - Fire Dampers
FDMA - Rectangular EIS Fire Damper (≤1600x1000mm) - Manual/Motorised - Fire Damper
FDMB - Rectangular EIS Fire Damper (≤1000x500mm) - Manual/Motorised - Fire Damper
FDML - EIS Multi-Blade Motorised Fire Damper (≤1000x1000mm) - Fire Damper
FDMQ - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMQ 120 - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMQ 180 - Rectangular EIS Fire Damper (≤1500x800mm) - Manual/Motorised - Fire Damper
FDMR 180 - Circular EIS Fire Damper (Ø200-800mm) - Manual/Motorised - Fire Damper
FDMR 60 - Circular EIS Fire Damper (Ø100-400mm) - Manual/Motorised - Fire Damper