NBS Source
I'm a manufacturer

EVAC-ALERT Evacuation Alert Panel to BS 8629

Verified by manufacturer 1 month ago

C-TEC (Computionics Limited)

A BS 8629 compliant evacuation alert panel housed in the Gerda cabinet.

Jump to:
BOS
+44 (0) 1942 322744 Website

Application

Evacuation alert panel suitable for use by firefighters in high-rise residential buildings to evacuate all or part of the building in an emergency.


The Gerda cabinet: suitable for applications in unmanned, less secure areas.

Description

A BS 8629 compliant evacuation alert panel housed in the Gerda cabinet.


Designed for unmanned, less secure areas the Gerda cabinet is a robust vandal-resistant cabinet to STS 205 and EN 1303.

 

Features and benefits:

  • Supplied as a two loop eight zone panel expandable to 48 zones and four loops using add-on parts.
  • Bright LED indicators, easy-to-operate evacuation toggle switches and a concealed maintenance interface.
  • Firefighter controls fully compliant with BS 8629.
  • Reliable hard-wired technology.
  • Can be connected to self-testing evacuation alert sounders, visual indicators and vibrating pillow pads.
  • Powered by C-TEC’s powerful ‘CAST’ protocol & compatible with our ENVISION data management software.
  • Customisable ‘slide-in’ floor/ zone labelling system.
  • BF321 Evacuation Alert Panel Mains Keyswitch also available - allows the Mains supply to the panel to be switched on or off in accordance with BS 5839-1.
  • The Gerda cabinet is a robust vandal-resistant cabinet to STS 205 and EN 1303.

General information

Color

Grey

Finish

Coated

Material

Steel

Shape

Rectangle

Length

200 mm

Manufacturer guidance

Depth.

Width

741 mm

Height

700 mm

Uniclass

Pr_75_80_30_29 Fire alarm panelsPrimary

CAWS

W90/120 Fire detection and alarm systems in domestic premises

Specification data - Fire alarm panels

Standard

To BS 8629.

Standby power supply

-

Standard

To BS EN 54-4.

Capacity

7–17 Ah.

Manufacturer guidance

Battery charge capacity.

Main display

LCD touchscreen (4.3 inch (109.22 mm), 480 x 272 pixel, 24 bit 16 M RGB colour).

Zone indication

Individual LED status indicators.

Installed capacity

Two loops.

Guidance for specification option:

Eight-zones. Each loop has a maximum output current of 450 mA (38 V) and is capable of supporting up to 255 devices over a length of up to 1000 m (using either 1 mm² or 1.5 mm² cable).

Indications

Power, power faults and general faults indicators.

Controls

Silence fault warning sounder, activate/ deactivate alert devices. Maintenance: interactive touchscreen with menu sensitive buttons; 1 x keyswitch allowing direct access to access level 2 (AL2).

Outputs

Output to evacuation alert sounders.

Output to visual indicators.

Output to vibrating pillow pads.

Other.

Guidance for specification option:

Consult manufacturer and insert requirements.

Input device

Two programmable inputs.

Guidance for specification option:

Programmable from C&Es. 470 Ω to trigger. Maximum input voltage 27V (non-latching).

Features

Automatic device address setup via control and indicating equipment (CIE).

Manual device address setup via CIE.

End of line (EOL) devices for unused sounder circuits and unused monitored inputs.

Guidance for specification option:

6 KΩ 0.25 W EOL resistors.

Enclosure

-

Ingress protection (minimum)

IP30.

Guidance for specification option:

To EN 60529.

Material

Steel.

Finish

Epoxy paint.

Colour

External: silver grey steel RAL 9006.
Internal: satin light grey RAL 7035.

Mounting

Surface.

Operating temperature

-10°C to +40°C.

Operating humidity

95% (non-condensing).

Manufacturer guidance

Maximum humidity.

Dimensions

741 x 700 x 200 mm.

Manufacturer guidance

Width x height x depth (TBC).

Protocols

CAST®.

Guidance for specification option:

(C-TEC Addressable System Technology) - a proprietary communication protocol. 

Battery type

2 x 12 V 17/ 22 Ah valve-regulated lead-acid (VRLA) batteries connected in series.

Security

BMTrada certified to STS 205 Issue 4/BR2. Lock certified to EN1303.

Guidance for specification option:

High security keys included.

Mains

230V 50/ 60Hz.

Current

1.3A maximum.

Manufacturer guidance

Mains rated current.

Output

5 A at 230 V a.c.

Manufacturer guidance

Total output current limited to.

Power supply

27.3 V d.c. ± 1% nominal at 20°C.

Manufacturer guidance

Internal power supply.

Ancillaries

Not required.

EAP02LOOP/CA loop card.

Guidance for specification option:

Provides two extra CAST protocol loops; maximum one per EAP2/8/CA/CHASSIS.

EAP8SWITCH additional eight way switch and indicator zone card.

Guidance for specification option:

Maximum five additional zone cards per EAP2/8/CA/CHASSIS.

Sustainability data

Country of product manufacture

United Kingdom

Material

Steel

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

Datasheet for C-TEC's EAP2/8/CA/CHASSIS + EAPBOX

Datasheet for C-TEC's EAP2/8/CA/CHASSIS + EAPBOX

EVAC-ALERT Consultants Specification

EVAC-ALERT Consultants Specification

EVAC-ALERT EU  Declaration of Conformity (CoC)

EVAC-ALERT EU Declaration of Conformity (CoC)

EVAC-ALERT Sales Brochure

EVAC-ALERT Sales Brochure

GERDA EACIE Enclosure Spec Sheet

GERDA EACIE Enclosure Spec Sheet

Similar products from C-TEC (Computionics Limited)

EVAC-ALERT Evacuation Alert System to BS 8629

EVAC-ALERT Evacuation Alert System to BS 8629