Eurothane EuroDeck™
Description

Eurothane Eurodeck™ insulation is a high performance rigid polyisocyanurate (PIR) foam board for use in warm flat roofs under mechanically fixed single ply membrane waterproofing systems. It is faced on both sides with a multi-layer coated aluminium foilW/m·K.

Features:

  • Manufactured to ISO 9001 Quality and ISO 14001 Environmental Management Systems.
  • Manufactured using a blowing agent with zero ozone depletion potential (ODP) and low global warming potential (GWP).
  • Low thermal conductivity of 0.022 W/mK.
  • Fully compatible with mechanically fixed single ply membrane waterproofing systems.
  • No requirement for roof ventilation and condensation within the roof is avoided as the structure is maintained at the internal temperature.
  • CE marked in accordance with harmonized European standard EN 13165.

General information

Features

Manufactured to ISO 9001 Quality and ISO 14001 Environmental Management Systems

Manufactured using a blowing agent with zero ozone depletion potential (ODP) and low global warming potential (GWP)

Low thermal conductivity of 0.022 W/mK

Fully compatible with mechanically fixed single ply membrane waterproofing systems

No requirement for roof ventilation and condensation within the roof is avoided as the structure is maintained at the internal temperature

Show more

Uniclass 2015

Pr_25_71_63_66 Polyisocyanurate (PIR) foam boardsPrimary

CAWS

J42/10 Warm deck roof covering

J42/420 Rigid urethane foam warm deck roof insulation

Specification data - Polyisocyanurate (PIR) foam boards

Product Reference

Eurothane EuroDeck™

Thickness

60 mm

70 mm

75 mm

80 mm

90 mm

100 mm

110 mm

120 mm

130 mm

140 mm

150 mm

Standard product features

Board size:

2400 x 1200 mm.

Thermal conductivity:

0.022 W/mK.

Fire Performance:

Euroclass F (EN 13501-1), Class 1 (BS 476-7). When tested in accordance with BS 476-3: 2004, the rating achieved will vary depending on the single ply membrane used.

Compressive strength:

Exceeds 150 kPa at yield, and suitable for loads associated with maintenance traffic. For heavier traffic, extra precautions should be taken (consult the membrane manufacturer for appropriate details). Care must be taken to avoid damage to boards by impact or concentrated loads during installation.

Product Options

Roof drainage:

To ensure adequate drainage the roof should have a minimum finished fall of 1:80. This may mean designing for twice the minimum finished fall to account for building inaccuracies, roof deflection and building settlement.

Thermal bridging:

With increasing levels of insulation it is important to ensure the continuity of insulation at the junction of elements.

Wind uplift:

The wind uplift force exerted on the roof will vary according to geographical location, site location and building height. Reference should be made to BS 6399 and the membrane manufacturer’s recommendations for the number of fixings and the fixing pattern.