Downer Framing DCS004 is a mechanical secret fix cladding subframe system. Aluminium cladding subframe system, designed to provide a mechanical secret fix support to most rainscreen cladding panels.
Downer Framing's DCS004 is a mechanical secret fix cladding framing system, designed to provide a mechanical secret fix support to most rainscreen cladding panels.
HORIZONTAL RAILS INSTALLATION
The horizontal cladding rails are fixed onto the vertical sub-frame and should align with DCS004 hangers fitted to the rear face of the panel.
DCS004 Horizontal Carrier Rails (HCR) are supplied in 3.0 and/or 6.0m lengths. Generally, these are installed in max. 3m lengths and cut to suit panel widths.
1 . 2
Layout position of the HCR by projecting horizontal datum lines across the elevation and mark position on to the vertical rails.
Secure the cladding rails to the vertical substructure with 2no. low profile self- drilling 5.5 x 25mm screws per intersection or as dictated by structural calculations.
Each HCR must be level and parallel to the others. Any joints between adjacent rails should be set at a minimum of 10mm for expansion.
Downer Framing DCS004 rainscreen framing system is designed to provide a mechanical secret fix support to most rainscreen cladding panels using the principle of a ventilated facade. The system offers design freedom to suit project specific thermal and structural demands and variation in cavity depths.
Features and benefits:
System components:
Downer Framing has now launched Downer Designer which is aimed at optimising rainscreen subframe calculations. This easy to use online portal offers clients the opportunity to calculate multiple projects and store them all for easy reference in a dedicated account. The Downer Framing support team aims to have calculations back in the former of a tailored project pack in less than 48 hours! https://downerframing.com/downer-designer
DOWNER FRAMING ORIGINAL HELPING HAND® FRAMING SYSTEM
As the original HELPING HAND framing system, Downer framing rainscreen subframe has been helping contractors, installers and architects realise their project visions for decades. It is highly versatile, combining with a diverse range of facade solutions.
DCS004 SYSTEM OVERVIEW
Downer DCS004 framing system is designed to provide a mechanical secret fix support to most rainscreen cladding panels using the principle of a ventilated façade.
DCS004 MSF can be installed onto our DCS031 Helping Hand, DCS041 Floor to Floor or DCS021 Omega & Zed system offering design freedom to suit project specific thermal and structural demands and variation in cavity depths.
All Downer Framing Systems and rainscreen framing calculations can be obtained via our free to use online tool, Downer Designer, which enables you to outline all your project specific rainscreen requirements to generate your optimal framing design. All of which is stored and managed in your own personal online account.
Simply enter the information you know, along with any detail specific requirements. Our technical team will then provide you with: static and thermal calculations, along with relevant costings, optimised component and fixing configurations, and NBS specification – all of which you can print off or save as a pdf. Check it out here.
Color | Silver Grey |
Finish | Mill |
Material | Aluminium |
Shape | Other |
Length | 3000 mm 6000 mm |
Width | Bespoke |
Height | Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
Standards | To BS EN 755-1 alloy EN AW-6063 and EN AW-6005A and suitable for the specified finish. |
Section | Horizontal carrier rail.Manufacturer guidanceDCS004 rail profile. |
Size | 3000 mm.6000 mm.Manufacturer guidanceDCS004 rail length. |
Factory finish | Mill. |
Colour | Natural. |
Hangers | DSCS004 HA50A. Guidance for specification option: 2 x Ø7mm holes @ 30 mm. DSCS004 HAKE50. Guidance for specification option: Square hole 10.2 mm (Eternit Keil Anchor). DSCS004 HAK50. Guidance for specification option: Hex hole 9.2 mm (Keil Anchor). DSCS004 HF50A. Guidance for specification option: 2 x Ø7mm holes @ 30 mm. DSCS004 HFKE50. Guidance for specification option: Square hole 10.2 mm (Eternit Keil Anchor). Manufacturer guidanceDCS004 panel hangers. |
Brackets | Downer DCS031 HELPING HAND® brackets. Guidance for specification option: Consult manufacturer's literature for detail and insert requirements. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium |
Recyclability | 100 recyclable aluminium rainscreen framing |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 79 % |
Expected Life | 30 year |