Verified by manufacturer 2 months ago
ETBH16E6V + EPRA14DV3
Quiet Mark Certification
Certificate type
Quiet Mark certified high capacity, high temperature air-to-water heat pump.
Suitable for use in domestic applications, specifically designed for the renovation market.
A high temperature air-to-water heat pump for heating, cooling and domestic hot water. It has been designed for lower acoustic levels to meet the needs of urban areas and homeowner expectations.
Features both an indoor and outdoor unit.
Features and benefits:
For full technical information, consult manufacturer's literature.
Components:
Color | Silver Black White Manufacturer guidance
|
Material | Steel Guidance for specification option: Polyester painted galvanised steel plate (EPRA14-16DV3). Resin Guidance for specification option: Resin sheet material (ETBH16E6V, ETBH16E9W, ETBX16E6V, ETBX16E9W). |
Shape | Rectangle |
Length | Manufacturer guidanceDependent on unit specified, see specification data for details. |
Width | Manufacturer guidanceDependent on unit specified, see specification data for details. |
Height | Manufacturer guidanceDependent on unit specified, see specification data for details. |
Uniclass | |
CAWS | T90/505 Air-to-water heat pumps T90/505 Air-to-water heat pumps |
Standards | |
Test requirements | To BS EN 14511. |
Heat pump type | Split. |
Mode | Heating. |
Coefficient of performance (minimum) | 4.67 kW.Guidance for specification option: Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). |
Output | |
Heating | 5.69 kW (nominal).Guidance for specification option: Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). |
Fan | |
Type | Propeller. |
Fan drive | Direct. |
Configuration | Horizontal. |
Electrical supply type | Single phase.Guidance for specification option: 230 V/ 50 Hz. |
Compressor | |
Type | Scroll. |
Sealing | Hermetically sealed. |
Drive | Inverter driven. |
Refrigerant | R32.Guidance for specification option:
|
Unit dimensions | 1003 x 1270 x 533 mm (EPRA14DV3); 840 x 440 x 390 mm (ETBH16E6V). Manufacturer guidanceHeight x width x depth. |
Unit weight | 146 kg (EPRA14DV3); 38 kg (ETBH16E6V). |
HeatingWaterFlowRate | 16.3 L/min. Guidance for specification option: Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). Manufacturer guidanceWater side heat exchanger water flow rate. |
Sound | To EN14825, 54.0 dB(A) (outdoor); 44.0 dB(A) (indoor). Manufacturer guidanceSound power level. |
Air flow | 3918 m³/h. Manufacturer guidanceAir to water unit rated airflow (outdoor). |
Integral accessories | Integrated back up heater, 6 kW (2 step). |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |