Verified by manufacturer 3 months ago
EHVH04SU18E6V + ERGA04EV
Low temperature, low capacity R-Split heat pump.
For use in domestic applications and particularly suitable for low energy houses.
Indoor units available in two variants. Integrated Floor standing which is a combined stainless steel domestic hot water tank (180 L or 230 L). Indoor unit also available in wall mounted version which can be used with Daikin standalone domestic hot water tank.
Both variants can be combined with the same outdoor unit model to provide a heat pump solution.
Features and benefits:
For full technical information, consult manufacturer's literature.
Components:
Color | White Black |
Material | Steel Guidance for specification option: Polyester pained galvanized steel plate - ERG(04/06/08)EV casing material. Stainless steel Guidance for specification option: Domestic hot water tank. Metal Guidance for specification option: EHVH-UE6V casing material. |
Shape | Rectangle |
Length | 388 mm |
Width | 884 mm |
Height | 740 mm |
Warranty description | Five year |
Uniclass | |
CAWS | T90/505 Air-to-water heat pumps T90/505 Air-to-water heat pumps |
Heat pump type | Split. |
Mode | Heating. |
Coefficient of performance (minimum) | 5.10 (condition 1); 3.65 (condition 2).Guidance for specification option:
|
Output | |
Heating | 4.30 kW (condition 1); 4.60 kW (condition 2).Guidance for specification option:
|
Fan | |
Type | Propeller. |
Configuration | Horizontal. |
Compressor | |
Type | Swing. |
Sealing | Hermetically sealed. |
Drive | Inverter driven. |
Refrigerant | R32.Guidance for specification option:
|
Sound | To EN14825, 58 dB(A) (outdoor); 42 dB(A) (indoor). Manufacturer guidanceSound power level. |
Air flow | 2280 m³/h. Manufacturer guidanceAir to water unit rated airflow (outdoor). |
Unit dimensions | 740 x 884 x 388 mm (ERGA04EV); 1650 x 595 x 625 mm (EHVH04SU18E6V). Manufacturer guidanceUnit height x width x depth. |
Unit weight | 58.5 kg (ERGA04EV); 119 kg (EHVH04SU18E6V). |
Tank type | Stainless steel (EN 1.4521) domestic hot water tank, 180 L. Guidance for specification option:
|
Safety | High pressure switch. |
HeatingWaterFlowRate | 12.3 L/min (condition 1); 13.2 (condition 2). Guidance for specification option:
Manufacturer guidanceWater side heat exchanger water flow rate. |
Heat | 1 hour 28 minutes. Manufacturer guidanceHeat up time from 10°C to 50°C. |
Heater | No back-up heater. Integrated back-up heater - 3 kW. Integrated back-up heater - 6 kW. Integrated back-up heater - 9 kW. Manufacturer guidanceBack-up heater for EHVH-UE6V. |
Ingress protection (IP) rating | IPX4 (ERGA04-08EV); IP X0B (EHVH-UE6V). |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Daikin Altherma High Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 14-16-18) - Heating system
Daikin Altherma High Capacity R32 Monobloc EB/DLA-D3V3/W1 (Sizes 9-11-14-16) - Heating system
Daikin Altherma Low Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 8-10-12) - Heating system
Daikin Altherma Low Capacity R32 Monobloc EB/DLA-EV3 (Sizes 4-6-8) - Heat pump
Low Temperature High Capacity R-Split Heat Pump (Size 11-14-16) - Water heater