CS Allway® HOD-HD and HOD-HDS Series Heavy Duty Floor Joint Covers - Dual Gasket

Verified by manufacturer 11 months ago

Allway® HOD-200HD floor-to-floor covers

Construction Specialties (UK) Ltd Variant:

Heavy-duty, dual gasket floor joint covers with an extra deep recess in the centre section to accept thick floor finishes, designed for flush fitting.

Jump to:
+44 (0)1296 652800 Website

Application

Floor joint applications requiring heavy-duty floor covers with an extra deep recess to accept thick floor finishes.

Description

Heavy-duty dual gasketed floor covers with an extra deep recess in the centre section to accept floor finishes up to 25 mm thickness. Installed in a recess for flush fitting with surrounding floor finish.


Features and benefits:

  • Joint width: up to 50 mm.
  • Horizontal movement: up to +30 mm.
  • Vertical movement: up to ±5 mm.
  • Lateral movement: up to ±10 mm.
  • Load capability: 1000 kg point load.
  • Suitable for most floor finishes, maximum thickness 25 mm.
  • For interior and exterior applications with heavy wheeled equipment.
  • HOD-HDS features stainless steel capping to aluminium frames.
  • Floor fixings (by others) to suit substrate at 450 mm centres and to achieve minimum 40 mm embedment.

General information

Color

Black

Grey

Finish

Mill

Guidance for specification option:

Aluminium frames.

Polished

Guidance for specification option:

HOD-HDS is supplied with polished s/steel capping.

Material

Aluminium

Guidance for specification option:

Frame.

PVC

Guidance for specification option:

Insert.

Uniclass

Pr_35_90_53_86 Strip movement jointsPrimary

CAWS

E40/545 Compressible sealing strip system

E40/545 Compressible sealing strip system

Product range

CS Allway Gasketed Expansion Joint Covers for Floors

Specification data - Strip movement joints

Joint width

50 mm.

Edging

-

Material

Aluminium.

Finish

Mill finish.

Colour

Silver.

Insert

-

Material

PVC gasket (dual).

Colour

Black.

Grey.

FrameDepth

44 mm.

Barriers

Not required.

Fire barrier.

Guidance for specification option:

Consult manufacturer for details and sizes, and insert requirements.

Acoustic barrier.

Guidance for specification option:

Consult manufacturer for details and sizes, and insert requirements.

Moisture barrier.

Guidance for specification option:

Consult manufacturer for details and sizes, and insert requirements.

Movement

Horizontal: ±30 mm; vertical: ±5 mm; lateral: ±10 mm.

Dimensions of recess (w x h)

Minimum recess width/ depth required: 348/ 50 mm.

Dimensions (visible width)

206 mm.

Literature

CS Allway Expansion Joint Covers (2023)

CS Allway Expansion Joint Covers (2023)