Verified by manufacturer 1 month ago
A thermoplastic waterproofing membrane with XP technology core.
Suitable applications include:
A 1.5 mm nominal thermoplastic membrane reinforced with a 90 g/m² polyester reinforcing scrim, integrally bonded to an XP Technology Core. Polymer technology provides performance in a wide range of ground contaminates, including high-salinity conditions.
The barrier performance starts with a thermoplastic membrane with welded seams, providing a monolithic watertight barrier layer. The thermoplastic membrane is reinforced with a polyester reinforcing scrim and is produced with DuPont’s Elvaloy-KEE® (Keytone Ethylene Ester), a solid phase high molecular weight ethylene interpolymer.
Features and benefits:
Color | Yellow |
Material | Polymer Plastic Polyester Manufacturer guidance1.5 mm nominal thermoplastic membrane reinforced with a 90 g/m² polyester reinforcing scrim integrally bonded to an XP Technology Core. |
Shape | Rectangle |
Length | 12900 mm |
Width | 1700 mm |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/12 Inverted roof covering J42/380 Protection layer J42/383 Separating layer J42/385 Filter layer Q37/130 Extensive green roof Q37/110 Intensive green roof Q37/120 Simple intensive green roof |
Material | Manufacturer guidance1.5 mm nominal thermoplastic membrane reinforced with a 90 g/m² polyester reinforcing scrim integrally bonded to an XP Technology Core. |
Purpose | Damp-proof membrane. |
Standard | Guidance for specification option: Consult manufacturer for further information. |
Performance characteristics | |
Tensile strength (minimum) | ≥1000 N/50 mm to EN 12344-2. |
Tear resistance | ≥200 N to EN 12310-2. |
Elongation to break | ≥26% to EN 12311-2. |
Resistant to underground gases | Radon, Methane, Carbon dioxide. |
Water vapour resistance (minimum) | ≥18.000 μ (+30%) to EN 1931. |
Fire performance | Broof (T1) to EN 13501-5. |
UV stabilization | Resistant to EN 1297, 1000 hours. |
Antistatic properties | ≥20 kg to EN 12730. |
Form | Reinforced. |
Root inhibitor | Resistant to root penetration to EN 13948. |
Physical properties | |
Colour | Guidance for specification option: Consult manufacturer for further information. |
Dimensions | |
Thickness (minimum) | Guidance for specification option: Consult manufacturer for further information. |
Width (minimum) | 1.7 m (1.55 m wide thermoplastic membrane).Guidance for specification option: With XP Technology Core offset by 150 mm along the long roll edge; consult manufacturer for further information. |
Roll length (minimum) | 12.9 m.Guidance for specification option: Consult manufacturer for further information. |
Accessories | Not required. Adhesive SB-100. Guidance for specification option: Adhesive for securing COREFLASH membranes to various substrates, including cured concrete, wood, metal and cementitious boards. Akwaswell. Guidance for specification option: Hydrophilic polyurethane caulk used for detail work including pipe penetrations. Cetseal. Guidance for specification option: A multipurpose UV stable single component polyether moisture cure sealant/ adhesive. Primary applications are ground termination sealant, membrane lap sealant and water-stop adhesive. Corecap Tie-Back Covers. Guidance for specification option: Preformed non-reinforced thermoplastic flashings, designed to provide a welded thermoplastic cover over tie-back heads on property line shoring walls; three preformed sizes available. CORECAP(s) used in conjunction with same size rigid TB-Boot. |
Watertightness | Waterproof to EN 1928. |
Reaction to fire classification | Class E to EN 13501-1. |
Peel resistance of joints (to BS EN 12316-1) | ≥300 N/50 mm. |
Joint strength | ≥900 N/50 mm to EN 12317-2. |
Impact resistance | ≥1000 mm to EN 12691. |
Dimensional stability | ≤1% to EN 1107-2. |
Foldability at low temperature (to EN 1107-2) | ≤–50°C to EN 495-5. |
Chemical resistance | Resistant to effects of liquid chemicals including water to EN 1847 (28 days/ 23°C). |
Radon transmission rate 0.47 x 10-9m/s SP. Radon gas permeability | 5.3 x 10^-12 m²·s^-1 to K124/02-95. |
Methane transmission rate | 18 mL/m²·day·atm to ISO 15105-1. |
Carbon dioxide transmission rate | 14 mL/m²·day·atm to ISO 15105-1. |
Weather resistance | Hail resistance: ≥17 m/s to EN 13583. |
Roll size | 1.55 m wide thermoplastic membrane with XP Technology Core offset by 150 mm along the long roll edge. |