NBS Source
I'm a manufacturer

Continuous Thermoformed Rooflights

Verified by manufacturer 16 days ago

VELUX Commercial

Continuous polycarbonate rooflights which create thermoformed units, joined without the use of glazing bars.

Jump to:
+44 (0) 1592 778916 Website

Application

Flat roof 0–15°.

Description

Polycarbonate linear rooflights which create thermoformed units, joined without the use of glazing bars. Available in widths up to 2.4 m, with no limit on length.


Features and benefits:

  • Triple glazed (1.8W/m2K) as standard, and formed from enhanced UV-protected polycarbonate with vented airspaces to satisfy the requirements of Part L of the Building Regulations.
  • Single (5.3W/m2K) and double-skin (2.7W/m2K) options (which fall outside Part L) are also available.
  • Supplied in two options: as glazing only, or with a roof attachment.
  • Non-fragile – achieves a Class B rating to ACR[M]001:2019.

General information

Color

Bronze

Guidance for specification option:

Reduces light transmission and solar gain.

Clear

Guidance for specification option:

Offers high light transmission and allows full vision of views or objects.

Material

Polycarbonate

Shape

Square

Rectangle

Length

Bespoke

Width

600 mm

900 mm

1200 mm

1500 mm

1800 mm

Show more

Warranty description

Guidance for specification option:

Available on request

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Specification data - Framed rooflights

Form

Linked dome.

Linked pyramid.

Thermoformed barrel vault.

Size

600 mm wide x length.

900 mm wide x length.

1200 mm wide x length.

1500 mm wide x length.

1800 mm wide x length.

2100 mm wide x length.

2400 mm wide x length.

Product performance

-

Fire performance

-

Fire resistance

To BS 476, Part 7: Class 1, AA.

Reaction to fire

EN 13501-1: Class B-s1,d0.

Guidance for specification option:

Surface spread of flame: EN 13501-5 + A1: Broof (t4).

Whole window U-value

1.8 W/m²K.

Guidance for specification option:

Triple skin polycarbonate.

Glazing or infill

-

Type

Polycarbonate

Construction

Double skin (Code 02).

Single skin (Code 01).

Triple skin (Code 03).

Guidance for specification option:

Standard.

Colour

Bronze.

Guidance for specification option:

Reduces light transmission and solar gain.

Clear.

Guidance for specification option:

Offers high light transmission and allows full vision of views or objects.

Diffused.

Guidance for specification option:

Offers high light transmission and prevents vision of views and objects.

Opal.

Guidance for specification option:

Prevents vision of views and objects.

Coating

Manufacturer's standard.

Integral kerb

Guidance for specification option:

Available on request, PVC-U or aluminium. Consult manufacturer and insert requirements.

Operation

-

Type

Fixed.

Accessories

None.

Intruder grid – Code IG.

Guidance for specification option:

3 mm diameter, fully welded, steel mesh in a 75 mm grid, which is fixed between the upstand and the roof structure. The grid will resist entry even when the rooflight has been compromised or removed.

Execution

Installation of framed rooflights.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

Guidance for specification option:

Meets BRE EN 15804:2012+A1:2012

Recyclability

95%

Case studies

Thomas Buxton Primary

Thomas Buxton Primary

Bespoke structural glazing at Braywick Leisure Centre

Bespoke structural glazing at Braywick Leisure Centre

Similar products from VELUX Commercial

S-Line Rooflight

S-Line Rooflight

VELUX Glazing Panels Double Glazing - Roof Light

VELUX Glazing Panels Double Glazing - Roof Light

VELUX Glazing Panels Triple Glazing

VELUX Glazing Panels Triple Glazing

VELUX Modular Rooflights

VELUX Modular Rooflights

VMS Atrium Longlight 5-25° - Rooflight

VMS Atrium Longlight 5-25° - Rooflight

VMS Atrium Ridgelight 25-40° - Rooflight

VMS Atrium Ridgelight 25-40° - Rooflight

VMS Fixed Module - Skylight

VMS Fixed Module - Skylight

VMS Longlight 5-25° - Rooflight

VMS Longlight 5-25° - Rooflight

VMS Northlight 25-90° - Rooflight

VMS Northlight 25-90° - Rooflight

VMS Ridgelight 25-40° - Rooflight

VMS Ridgelight 25-40° - Rooflight