NBS Source
I'm a manufacturer

CMS30 Bonding Brick Slip Cladding System

Verified by manufacturer 11 days ago

Cladmate Facade Systems

Lightweight bonding brick slip cladding system.

Jump to:
+44 020 3949 8826 Website

Application

Suitable for almost all substrates, including timber frame and concrete blockwork, and can be used both on internal and external applications.

Suitable for buildings up to 18 m.

Description

Bonding brick slip cladding system.


Features and benefits:

  • Suitable for buildings up to 18 m.
  • Suitable for almost all substrates, including timber frame and concrete blockwork, and can be used both on internal and external applications.
  • Helps achieve required U-values when teamed up with stone wool insulation.
  • Lightweight; system weight is approx. 53 kg/m².
  • Compatible with brick slips of 15 mm thickness in both imperial and metric sizes, and different brick patterns.

General information

Finish

Brick

Material

Metal

Brick

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

Thermal insulation

TerraWool Rainclad TWR60, 30 mm-thick.

TerraWool Rainclad TWR60, 50 mm-thick.

TerraWool Rainclad TWR60, 60 mm-thick

TerraWool Rainclad TWR60, 80 mm-thick

TerraWool Rainclad TWR60, 90 mm-thick

TerraWool Rainclad TWR60, 100 mm-thick

TerraWool Rainclad TWR60, 120 mm-thick

TerraWool Rainclad TWR60, 140 mm-thick

TerraWool Rainclad TWR60, 150 mm-thick

TerraWool Rainclad TWR60, 160 mm-thick

TerraWool Rainclad TWR60, 180 mm-thick

TerraWool Rainclad TWR60, 200 mm-thick

TerraWool Rainclad TWR60, 220 mm-thick

TerraWool Rainclad TWR60, 240 mm-thick

Other.

Guidance for specification option:

Insert requirements. Standard thickness slabs can be combined as required, consult manufacturer for details.

Manufacturer guidance

To be placed between vertical rails prior to installing horizontal rails.

Stone mineral wool slabs are 1200 x 600 mm as standard.

Breather membrane

-

Material

Guidance for specification option:

Consult manufacturer for recommendations and insert requirements.

Fasteners

Guidance for specification option:

Consult manufacturer for recommendations and insert requirements.

Secondary support structure

Guidance for specification option:

Insert details e.g. drawing reference or schedule.

  • Cladmate T, L and corner profile rails available in aluminium/ grade 316 stainless steel.
  • Brackets: Insert requirements; Cladmate Fortis single and double support brackets, 40–300 mm, in 6063 T3 aluminium and grade 316 stainless steel. With thermal isolators.

Cladding panels

-

Material

Slip board (cement particleboard)/ brick slips.

Guidance for specification option:

Board:

  • Consult manufacturer for details.

Brick slips:

  • Consult manufacturer for options and insert requirements including laying pattern.
  • Compatible with clay brick slips of 15 mm thickness, extruded/cut.

Reveals

Guidance for specification option:

Insert requirements or omit.

Fixings

Guidance for specification option:

EJOT fixings for timber/ steel studwork, masonry, concrete, brickwork and blockwork substrates.

Insert requirements to suit.

Primer

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Other.

Guidance for specification option:

Insert requirements.

Adhesive

Terrabond.

Guidance for specification option:

Consult manufacturer for details.

Mortar

Terrabond T-Point pointing mortar.

Guidance for specification option:

Consult manufacturer for details.

Sustainability data

Contains Red List materials

No