Single leaf
BRE Certificate
Certificate type
High security swing gate system to LPS 1175 C5 (SR3) Issue 8.
CLD LockMaster S3 swing gates have been specially developed to blend in with a CLD Securus fence line. Available using a Securus S3 infill panel, LockMaster S3 offers security rated access control, whilst maintaining aesthetics. Tested by the Loss Prevention Certification Board (LPCB) to guarantee a minimum delay of five minutes against attack, LockMaster S3 is also Secured by Design accredited, making it a police preferred specification for security.
Features and benefits:
Color | Other Guidance for specification option: Any RAL colour. |
Finish | Powder-coated Galvanized |
Material | Steel |
Shape | Rectangle |
Width | Bespoke Guidance for specification option: To suit mesh infill panels. Single leaf: 900–4000mm. Double leaf:1200–8000 mm. |
Height | Bespoke Guidance for specification option: Double 2440–5000 mm to match fence panel. Single 2440–3000 mm or up to 5000 mm with lintel panel. |
Warranty description | 15 year Guidance for specification option: Minimum of 15 years against manufacturing defects. |
Uniclass | |
CAWS | Q40/570 Gates Q40/45 Gates |
Standard | To BS 1722-14. |
Dimensions | |
Span | Manufacturer guidanceTo suit mesh infill panels: Single leaf: 900–4000 mm. Insert requirements. |
Height | Manufacturer guidanceSingle 2440–3000 mm or up to 5000 mm with lintel panel. Insert requirements. |
Posts | Steel.Guidance for specification option: Post dimensions: 80 x 80 mm minimum. |
Gate leaves | Panel infill to match CLD Securus S2. |
Hardware | |
Hinges | 3 no. hinge sets with minimum M20 eye bolts. |
Securing | Slide bar with certified padlock.Key operated hook bolt lock. |
Finish as delivered | |
Applied finish | Polyester powder-coated. |
Colour and finish | RAL colour. Guidance for specification option: Any RAL available. Insert requirements. |
Configuration | Single leaf, inward opening. Single leaf, outward opening. |
Post foundations | Set posts in holes 450 mm square x 950 mm deep minimum. Guidance for specification option: The manufacturer advises that the contractor/ client is responsible for the foundation size suitable for the ground conditions and fence height. |
SecurityRating | LPS 1175 C5 (SR3) Issue 8. |
Frame | Vertical stiles/ horizontal rails (minimum): 50 x 50 x 3 mm SHS. |
Country of product manufacture | United Kingdom |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |