Two-layer, torch-applied, warm roof, bitumen membrane waterproofing system suitable for new build and refurbishment. Option of using a root-resistant capping sheet for green roof scenarios.

Jump to:
BOS
+44 (0)1473 257671 Website

Application

Suitable for new build and refurbishment, with an option of using a root-resistant capping sheet for green roof scenarios.

Description

Two-layer, torch-applied, warm roof, bitumen membrane waterproofing system, suitable for both new build and refurbishment applications.


Features and benefits:

  • Capping sheets with tensile strength of up to 800 N/50mm.
  • Withstands climatic extremes of over 100⁰C variation.
  • Expandable graphite fire-retardant prevents spread of flame.
  • Heavy-duty, robust and extremely tough.
  • Service life in excess of 35 years, as stated in BBA certificate 10/4744.
  • Resistant to European climatic conditions.
  • Membrane resists impact and tearing.
  • Can satisfy requirements of Part B of Building Regulations.

General information

Color

Black

Finish

Mineral

Manufacturer guidance

Mineral.

Material

Bitumen

Guidance for specification option:

Elastomer modified bitumen membrane.

Shape

Square

Rectangle

Warranty description

-

Manufacturer guidance

Guarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved installer. For full details and further information regarding guarantees and alternative systems please contact a local Bauder Representative or technical@bauder.co.uk.

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

Product range

Built-Up Bituminous Systems

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Bauder Activator-Primer (Canister), APR01-Black.

Bauder Quick Dry Bitumen Primer.

Manufacturer guidance

Contact manufacturer to confirm substrate suitability if required.

Skirtings and vertical work

As 'Horizontal work'.

Air and vapour control layer

-

Type

Bauder Super AL-E.

Guidance for specification option:

Torch-applied, styrene-butadiene-styrene (SBS) elastomeric bitumen air and vapour control layer, featuring a tear-resistant aluminium foil lining for vapour impermeability. Once installed, the product provides a temporary waterproofing layer, allowing internal works to be carried out immediately.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 3.5 mm.
  • Surface finish: top: mica; bottom: thermofusible polyethylene.
  • Weight: 4.5 kg/m².
  • Reinforcement: polyester-coated aluminium foil and 60 g/m² glass fleece.
  • Tensile strength: ≥400 N/50mm (length and diagonal).
  • Heat stability: +70°C.
  • Cold bending test: -20°C.
  • Elongation at break: ≥2% (length and diagonal).

Attachment

Torch applied.

Insulation

-

Type

BauderGLAS Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge.

Suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass flatboard insulation board.
  • Facing: Glass tissue or none-faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness: 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm.
  • Thermal conductivity: 0.036 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².

BauderGLAS Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge.

Suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass tapered insulation board.
  • Facing: Glass tissue or none-faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness (maximum): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm.
  • Thermal conductivity: 0.036 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².

BauderROCK Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge or mechanically fixed.

Mineral fibre insulation, suitable for projects that require a high level of sound reduction and/ or to be non-combustible.

  • Type: Dual density mineral wool flatboard.
  • Facing: Top: 300 g/m² glass fibre fleece; bottom: unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm (also available in tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

BauderROCK Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge or mechanically fixed.

Mineral fibre insulation, suitable for projects that require a high level of sound reduction and/ or to be non-combustible.

  • Type: Tapered insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; bottom: unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm (also available in tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

Fixing

PU Insulation Adhesive – Tin.

Guidance for specification option:

Not for foil to foil applications (e.g. FA-TE to FA-TE).

Activator-Primer (Canister), APR01-Black.

PU Insulation Adhesive – Twin cartridge.

Waterproof covering

-

First layer

-

Type

BauderFLEX G4E.

Guidance for specification option:

A 4 mm, torch-applied elastomeric bitumen underlayer with a woven glass reinforcement to provide tensile strength.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 4 mm.
  • Surface finish: Top: mica; bottom: thermofusible polyethylene.
  • Weight: 4.8 kg/m².
  • Tensile strength: ≥1200 N/50mm (length and diagonal).
  • Heat stability: +110°C.
  • Cold bending test: -30°C.
  • Elongation at break: ≥2% (length and diagonal).

Attachment

Torch applied.

Top layer

-

Type

K5E.

Guidance for specification option:

Elastomer bitumen, torch-on underlayer. Can also be used as a capping sheet in areas that will not be exposed to ultraviolet light. Product has been fire tested as part of a system assembly and this information can be obtained in the Fire Test Report available from Bauder Ltd.

  • Width: 1 m.
  • Length: 5 m.
  • Thickness: 5 mm.
  • Weight: 5.8 kg/m².
  • Surface: top: Mica; bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² recycled, spun-bound polyester.
  • Cold bending test: -30°C.
  • Softening point: >110°C.
  • Tensile strength: Length >800 N/50mm; transverse >800 N/50mm.
  • Elongation at break: Length >40%; transverse >40%.

K5K, Brown.

Guidance for specification option:

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation. Product has been fire tested as part of a system assembly and this information can be obtained in the Fire Test Report available from Bauder Ltd.

  • Width: 1 m.
  • Length: 5.2 m.
  • Thickness: 5 mm.
  • Weight: 6.5 kg/m² (charcoal grey); 6 kg/m² (Grey slate, brown).
  • Surface: Top mineral chippings.
  • Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² spun-bound polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >45%; transverse >45%.

K5K, Charcoal Grey.

Guidance for specification option:

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation. Product has been fire tested as part of a system assembly and this information can be obtained in the Fire Test Report available from Bauder Ltd.

  • Width: 1 m.
  • Length: 5.2 m.
  • Thickness: 5 mm.
  • Weight: 6.5 kg/m² (charcoal grey); 6 kg/m² (Grey slate, brown).
  • Surface: Top mineral chippings.
  • Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² spun-bound polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >45%; transverse >45%.

K5K, Grey Slate.

Guidance for specification option:

Elastomer bitumen torch-on capping sheet. The product features a spunbond polyester reinforcement to allow the finished product to cope with structural movement without fracture, and a mineral finish to provide protection against UV degradation. Product has been fire tested as part of a system assembly and this information can be obtained in the Fire Test Report available from Bauder Ltd.

  • Width: 1 m.
  • Length: 5.2 m.
  • Thickness: 5 mm.
  • Weight: 6.5 kg/m² (charcoal grey); 6 kg/m² (Grey slate, brown).
  • Surface: Top mineral chippings.
  • Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² spun-bound polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >45%; transverse >45%.

Manufacturer guidance

Not for use with green roof systems.

Attachment

Torch applied.

Detail work

-

Flashings

Not required.

Bauder GRP Trim.

Guidance for specification option:

GRP roof edge trim for use with Bauder bituminous roof systems. Available in colours of either grey or black, and a choice of profiles to suit the requirements of most projects. Consult manufacturer literature and insert requirements.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Skirtings and upstands

Not required.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast-curing waterproofing resin, containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen-free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid applied fast curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent, isocyanate and halogen free.

Welted drips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Cover strips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Ancillary items

Required.

Guidance for specification option:

Insert requirements.

Not required.

Surface protection

Not required.

Hard landscaping/ Ballast options.

Guidance for specification option:

Consult manufacturer for information.

System accessories

Not required.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are a specially designed secure clip that allows for movement.

  • Bauder Lightning conductor – Type 4: Polyvinyl chloride (PVC) coated or bare conductor.

Bauder insulated rainwater outlets.

Guidance for specification option:

For maintaining thermal continuity at drainage points. Suitable for warm, cold and inverted roof construction, the high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet.

Designed for use when connecting to conventional drainage systems, with excellent flow rate performance and is suitable for both new build and refurbishment projects. Outlets are included in the Bauder waterproofing system guarantee as they are integrated components.

Flow rate figures (where applicable) are based on BS EN 12056:3:2000, typically taken using a 35 mm header of water including leaf grille:

  • Bauder Bitumen Compact Vertical Outlet DN100: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Vertical Outlet DN70: Insulated internal outlet, 7.1 L/s.
  • Bauder Bitumen Vertical Outlet DN150: Insulated internal outlet, 7.2 L/s.
  • Bauder Bitumen Warm Roof Refurb Outlet DN63: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Warm Roof Refurb Outlet DN90: Insulated internal outlet, 5.7 L/s.
  • Bauder Bitumen Refurb Outlet DN95: Uninsulated straight drop outlet, designed to ensure that the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Refurb Outlet DN125: Uninsulated straight drop outlet, designed to ensure that the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Insulated Parapet Outlet DN100, including preassembled pipe and dome grate: 0.6 L/s connected to external pipework; 0.7 L/s connected to external hopper.
  • Bauder Parapet Emergency Overflow Stainless Steel DN70: emergency overflow/ tell-tale.

BauderSOLAR F XL Photovoltaic Mounting System.

Guidance for specification option:

Bauder Flat roof PV mounting solution for framed solar modules. The mounting units are secured to the roof using a membrane-to-membrane welding technique. This installation method means that the roof is not compromised by penetrations for fixings, nor is it ballasted, which would add additional weight loading to the roof. Specifically designed to be installed on Bauder bituminous or single-ply waterproofing systems and provide a lightweight, low-risk and quick-to-install mounting solution for framed solar modules.

Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

  • BauderDOME Rooflight.
  • BauderFLATGLASS.
  • Bauder Euroglaze Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight.
  • Bauder Fire Rated Rooflight.

Sustainability data

Material

Bitumen

Guidance for specification option:

Elastomer modified bitumen membrane.

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

3

IFC
-

1

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauder Total Roof Systems 10/4744

EPD

EPD

Environmental Product Declaration - RBM

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauder Total Roof Systems PLUS 10/4744

CCPI System

CCPI System

Bauder BTRS-BTGRS CCPI System Certificate