Total bitumen green inverted roof system, incorporating inverted insulation, torch-on bitumen root-resistant capping sheet with self-adhered bitumen underlayer.

Jump to:
+44 (0)1473 257671 Website

Application

Suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

Description

Total bitumen green inverted roof system, incorporating torch-on bitumen root-resistant capping sheet with self-adhered bitumen underlayer and inverted insulation.

Bauder Total Green Roof System (BTGRS) is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios where a green roof finish is required.

Bauder Inverted Roof systems should be ballasted/ landscaped to prevent wind uplift and/ or floatation.

Type, thickness, weight of landscaping should be agreed with Bauder per bespoke project basis.

 

Plus Points:

  • 5.2 mm SBS-modified elastomeric bitumen cap sheet with polyester fleece reinforcement.
  • Range of guarantee packages to fulfil cover requirements for project (dependent on system/ product selection). For more information contact manufacturer's technical department for a sample guarantee outlining cover level, terms and conditions.
  • Standards: BS EN 13707 Reinforced Bitumen Membrane Sheets for Roof Waterproofing.


Assessments and verifications:

  • CCPI Assessment 0007700017/1025: This systems CCPI mark provides accuracy of data delivering assurance to specifiers.
  • BBA Certificate 10/4744.
  • Fire properties – membranes deemed “unrestricted” in certain circumstances as categorized in the BBA certificate.
  • Service life > 35 years as stated in BBA certificate.
  • EPD certification on system components:
  • Bitumen membranes.

General information

Finish

Mineral

Material

Bitumen

Shape

Square

Rectangle

Length

Bespoke

Width

Bespoke

Warranty description

-

Manufacturer guidance

Guarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ guarantees.

All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved installer.

For full details and further information regarding guarantees and alternative systems please contact the local Bauder Representative or technical@bauder.co.uk.

Uniclass

Ss_30_40_30_71 Reinforced bitumen membrane inverted roof covering systemsPrimary

CAWS

J41/120 Built-up reinforced bitumen membrane inverted roof covering

Product range

Built-Up Bituminous Systems

Specification data - Reinforced bitumen membrane inverted roof covering systems

Preparation

-

Horizontal work

Activator-Primer (Canister) APR01 – Black.

Guidance for specification option:

Synthetic rubber resin-based primer, developed to provide the necessary preparation of substrates prior to the installation of self-adhesive and torch-applied membranes. The spray application offers improved film thickness speed of application (by up to 50% over roller applied products) and quick drying in a matter of minutes.

  • Coverage: Approximately 96 g/m² (300 mm-wide spray one coat, 192 g/m² two coats). Two coats may be required for very porous substrates.
  • Application temperature: +5 to +30°C.
  • Drying time (at 10°C): 5–10 minutes.
  • Colour: Black.
  • Recoat time if left exposed: Four hours.
  • Suitable substrates: Oriented strand board (OSB); plywood; timber; concrete; lightweight concrete or cementitious materials; metal; Bauder self-adhesive underlayers; existing asphalt and bitumen membranes; polyisocyanurate (PIR) insulation.
  • Non-suitable substrates: Mica finished surfaces (e.g. KSD FBS); Laminated paper-foil faced insulation; expanded polystyrene (EPS) or extruded polystyrene (XPS) insulations; BauderROCK or mineral wool insulation; BauderGLAS or cellular glass insulation; copper; thermoplastic waterproofing membranes.

SA Bonding Primer.

Guidance for specification option:

For Self-Adhesive membranes to Concrete and Screeded Substrates.

Synthetic rubber-based primer, specially formulated to increase the bond strength of Bauder self-adhesive bitumen membranes to a wide range of substrates, including timber, concrete, brick, metal and most plastics.

  • Coverage: Approximately 200–300 g/m² (depending on substrate porosity).
  • Application temperature: +5 to +30°C.
  • Drying time: Approx.30 mins, dependent upon ambient temperature and material porosity.
  • Colour: Black.
  • Recoat time if left exposed: Four hours.
  • Suitable substrates: timber, concrete, brick, metal and most plastics.

Manufacturer guidance

Contact manufacturer to confirm substrate suitability if required.

Skirtings and vertical work

As 'Horizontal work'.

Waterproof covering

-

First layer

-

Type

BauderTEC KSA DUO.

Guidance for specification option:

A self-adhesive SBS elastomeric bitumen underlayer with “DUO” lap technology to ensure thorough sealing of lap joints, even in lower temperatures. The product features a glass lattice reinforcement for strength and stability.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 3 mm.
  • Weight: 3.5 kg/m².
  • Surface: Top: Foil; Bottom: Peel off release film covering self-adhesive bitumen.
  • Reinforcement: 200 g/m² glass lattice.
  • Cold bending test: Top -25°C; Bottom -30°C.
  • Softening point: >100°C.
  • Tensile strength: Length >1000 N/50mm; transverse >1000 N/50mm.
  • Elongation at break: Length >2%; transverse >2%.

Manufacturer guidance

To be fully specified separately.

Attachment

Self-adhered.

Top layer

-

Type

BauderPLANT E.

Guidance for specification option:

Elastomer-bitumen capping sheet with root-resistance according to the FLL. The membrane is reinforced with 250 g/m² spunbond polyester fleece to allow the finished product to cope with structural movement without fracture. Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 5 m.
  • Thickness: 5.2 mm.
  • Weight: 6 kg/m².
  • Surface, top: green slate mineral chippings; bottom: thermofusible polyethylene.
  • Reinforcement: 250 g/m² recycled spunbond polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: length >1000 N/50 mm; transverse >1000 N/50mm.
  • Elongation at break: length >45%; transverse >45%.

Attachment

Torch applied.

Detail work

-

Flashings

Bauder GRP Trim.

Guidance for specification option:

GRP roof edge trim for use with Bauder bituminous roof systems. Available colours of either grey or black and a choice of profiles to suit the requirements of most projects.

Bauder GRP Water Check Trim.

Guidance for specification option:

GRP water check trim to be used on parapets and perimeter kerbs wider than 200 mm – must not be used on its own as a check kerb.

Available in black only.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Skirtings and upstands

Not required.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast-curing waterproofing resin, containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent-free, isocyanate-free and halogen-free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid-applied fast-curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent-free, isocyanate-free and halogen-free.

Welted drips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Cover strips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Ancillary items

Required.

Guidance for specification option:

Insert requirements.

Not required.

Insulation

-

Type

Bauder JFRI PREMIUM+ Inverted Insulation.

Guidance for specification option:

Insert required thickness, 85–240 mm in 5 mm increments.

 

Designed specifically for inverted roof applications.

  • Type: Rigid expanded polystyrene (EPS) insulation boards.
  • Facing: Unfaced.
  • Colour: Grey.
  • Nominal weight: 30 kg/m³.
  • Standard board size: 1215 x 1215 mm (including 15 mm rebate).
  • Thermal conductivity: Declared 0.031 W/m·K; design 0.031 W/m·K (may vary, dependent on thickness specified).
  • Design load compressive strength: 0.20 N/mm² with 10% nominal compression.
  • Recyclability: 100%.


Consult manufacturer's literature for further details.

Bauder JFRI PREMIUM (300) Inverted Insulation.

Guidance for specification option:

Insert required thickness, 90–240 mm in 5 mm increments.

 

Designed specifically for inverted roof applications.

  • Type: Rigid expanded polystyrene (EPS) insulation boards.
  • Facing: Unfaced.
  • Colour: White.
  • Weight: 40 kg/m³.
  • Standard board size: 1215 x 1215 mm (including 15 mm rebate).
  • Thermal conductivity: Declared 0.033 W/m·K; design 0.033–0.035 W/m·K (may vary, dependent on thickness specified and application).
  • Design load compressive strength: 0.30 N/mm² with 10% nominal compression.
  • Recyclability: 100%.


Consult manufacturer's literature for further details.

Bauder XPS (300) Inverted Flatboard.

Guidance for specification option:

Insert required thickness.

 

  • Type: Rigid extruded polystyrene insulation boards.
  • Facing: Smooth, self-finished.
  • Density: 30 kg/m³.
  • Standard board size: 1250 x 600 mm.
  • Board thickness: 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 80 mm, 100 mm, 120 mm, 140 mm.
  • Thermal conductivity: 30 mm: 0.034 W/m·K; 40–50 mm: 0.035 W/m·K; >50 mm: 0.036 W/m·K.
  • Compressive strength: 0.30 N/mm².

Bauder XPS (500) Inverted Flatboard.

Guidance for specification option:

Insert required thickness.

 

  • Type: Rigid extruded polystyrene insulation boards.
  • Facing: Smooth, self-finished.
  • Density: 35 kg/m³.
  • Standard board size: 1250 x 600 mm.
  • Board thickness: 40 mm, 50 mm, 60 mm, 70 mm, 80 mm, 100 mm, 120 mm, 140 mm.
  • Thermal conductivity: 40–60 mm: 0.034 W/m·K; >60 mm: 0.036 W/m·K.
  • Compressive strength: 0.50 N/mm².

BauderGLAS Inverted Insulation Flatboard.

Guidance for specification option:

Insert required thickness.


  • Type: Cellular glass with pre-applied inorganic coating on the topside. Both the core material and the coating have an A1 reaction to fire classification and are therefore non-combustible. Where more than one layer of insulation is required, BauderGLAS Slab T3+ will be used as the base layer.
  • Facing: Pre-applied inorganic coating.
  • Density: 100 kg/m².
  • Standard board size: 600 x 450 mm.
  • Board thickness: 100 mm, 120 mm, 140 mm, 160 mm, 180 mm, 200 mm.
  • Thermal conductivity: 0.043 W/m·K.
  • Compressive strength: 0.4 N/mm.

Attachment

Loose laid (and suitably ballasted).

Guidance for specification option:

  • Setting out: Loose lay insulation directly over the capping sheet to brick pattern with staggered joints. Minimize cutting and avoid small pieces at perimeters and penetrations. Dependent upon the total thickness required, it may be necessary to construct the insulation using two layers of board. The manufacturer/supplier can advise on the available combination options.
  • Joints: Butt together.
  • Loading over inverted insulation (minimum): Ballast (landscaping) should be installed onto the Bauder WFRL Membrane (Water Flow Reducing Layer) to a minimum depth required to achieve a permanent minimum 80 kg/m² and load which prevents wind uplift and flotation of the insulation in high winds and/or heavy rainfall.
  • Additional loading at perimeters: On high buildings in more exposed areas, wind uplift may be a problem and in these instances paving slab ballast must be considered. Paving slabs should be a minimum of 50 mm-thick. The slabs should be laid on paving slab supports of minimum 175 mm diameter (or equivalent base area).
  • All final details must to be confirmed with Bauder before proceeding.

Ballast

-

Manufacturer guidance

Insert requirements.

Loading over inverted insulation (minimum): Ballast (landscaping) should be installed onto the Bauder WFRL Membrane (Water Flow Reducing Layer) to a minimum depth required to achieve a permanent minimum 80 kg/m² and load which prevents wind uplift and flotation of the insulation in high winds and/or heavy rainfall.

System accessories

Not required.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are a specially designed secure clip that allows for movement.

  • Bauder Lightning conductor clips – Type 4: Polyvinyl chloride (PVC) coated or bare conductor.

Bauder rainwater outlets.

Guidance for specification option:

Bauder has a range of insulated or stainless-steel rainwater outlets.

The insulated outlets can be used for maintaining thermal continuity at drainage points. Suitable for warm, cold and inverted roof construction. The BRE Certified (report no. HPR357-303748) high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet body.

Designed for use when connecting to conventional drainage systems and is suitable for both new build and refurbishment projects. Outlets are included in the Bauder waterproofing system guarantee as they are integrated components.

Flow rate figures (where applicable) are based on BS EN 12056:3:2000, typically taken using a 35 mm header of water including leaf grille:

  • Bauder Bitumen Compact Vertical Outlet DN100: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Vertical Outlet DN70: Insulated internal outlet, 7.1 L/s.
  • Bauder Bitumen Vertical Outlet DN150: Insulated internal outlet, 7.2 L/s.
  • Bauder Bitumen Letterbox Parapet Outlet DN 205 including stainless-steel leaf guard, 2.02 L/s.
  • Bauder Bitumen Parapet Outlet DN 100 including stainless-steel leaf guard, 1.06 L/s.
  • Bauder Bitumen Vertical Refurb Outlet DN70, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Vertical Refurb Outlet DN95, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Vertical Refurb Outlet DN145, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Parapet ‘Tell-Tale’ Overflow DN50, designed to be used in conjunction with other roof drainage outlets to ensure that there is no water ingress into the build and that the structural load of the roof is not exceeded and provides a visible warning that the roof is holding excessive water.

Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

  • BauderDOME Rooflight.
  • Bauder Euroglaze Rooflight.
  • BauderFLATGLASS Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight
  • Bauder Fire Rated Rooflight.

Water Flow Reducing Layer/ Vapour Permeable Membrane

Bauder JFRI WFRL.

Guidance for specification option:

Flexible and breathable sheet of polypropylene strands randomly spun-bound together, supplied as part of the JFRI Inverted Insulation system to minimize water flow through and below the insulation, therefore improving thermal performance.

Supplied as part of the JFRI Inverted Insulation system to minimize water flow through and below the insulation.

  • Width: 3 m.
  • Length: 100 m.
  • Thickness: 0.45 mm.
  • Weight: 0.1 kg/m².
  • Colour: Black.

Bauder XPS WFRL.

Guidance for specification option:

Flexible and breathable geotextile membrane of polypropylene strands randomly spun-bound together, supplied as part of the Bauder XPS Inverted Insulation system to minimize water flow through and below the insulation, therefore improving thermal performance.

  • Width: 3 m.
  • Length: 100 m.
  • Thickness: 0.17 mm.
  • Weight: 0.06 kg/m².
  • Colour: White.

Surfacing layer

Not required.

Landscaping options.

Guidance for specification option:

Please refer to Bauder Extensive / Biodiverse / Intensive Landscaping systems.

Sustainability data

Material

Bitumen

Third party certifications

Third party certifications

EPD

EPD

Environmental Product Declaration - RBM

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauder Total Green Roof Systems 10/4744

CCPI System

CCPI System

Bauder BTRS-BTGRS CCPI System Certificate

Literature

Bauder Activator-Primer (Canister) APR01 - black

Bauder Activator-Primer (Canister) APR01 - black

BauderPLANT E Roofing membrane

BauderPLANT E Roofing membrane

Bauder Bitumen Compact Vertical Outlet DN 100

Bauder Bitumen Compact Vertical Outlet DN 100

Bauder Bitumen Vertical Outlet DN70 & 150

Bauder Bitumen Vertical Outlet DN70 & 150

Green Roof Systems - Bauder Brochure

Green Roof Systems - Bauder Brochure

New Build Flat Roof Solutions - Bauder brochure

New Build Flat Roof Solutions - Bauder brochure

Refurbishment Flat Roof Solutions - Bauder brochure

Refurbishment Flat Roof Solutions - Bauder brochure

Reinforced Bitumen Membrane Systems - Bauder brochure

Reinforced Bitumen Membrane Systems - Bauder brochure

BauderTEC KSA DUO Roofing membrane

BauderTEC KSA DUO Roofing membrane

Bauder LiquiFIBRE

Bauder LiquiFIBRE

Bauder LiquiDETAIL

Bauder LiquiDETAIL

Similar products from Bauder Ltd

Bauder Total Inverted Roof System - Torch Applied

Bauder Total Inverted Roof System - Torch Applied

Bauder Total Roof System Reinforced Bitumen Membrane Inverted Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Roof System Reinforced Bitumen Membrane Inverted Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauderflex Green Roof System Reinforced Bitumen Membrane Inverted Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauderflex Green Roof System Reinforced Bitumen Membrane Inverted Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauderflex Inverted Roof System - Torch Applied

Bauderflex Inverted Roof System - Torch Applied

Bauderflex Roof System Reinforced Bitumen Membrane Inverted Roof Covering System Self-Adhered (with Torch-on Capping Sheet)

Bauderflex Roof System Reinforced Bitumen Membrane Inverted Roof Covering System Self-Adhered (with Torch-on Capping Sheet)