Verified by manufacturer 9 months ago
LiquiTOP System
BBA Agrément Certificate
Certificate type
EPD
Certificate type
Cold liquid applied, warm roof system suitable for new build and refurbishment applications.
Suitable for new build and refurbishment applications.
Bauder LiquiTOP is a moisture triggered curing, single component, glass fibre mat reinforced polyurethane liquid, for the refurbishment of existing flat roofs and new build applications.
Plus points:
Verified properties:
System includes:
or
System components:
Color | Grey Guidance for specification option: Dark Grey (Approx. RAL 7011) Mist Grey (Approx. RAL 7040) Manufacturer guidanceLiquiTOP PU Dark Grey (Approx. RAL 7011) is suggested as the top layer. |
Finish | Smooth |
Material | Polyurethane |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Warranty description | Manufacturer guidanceA comprehensive range of guarantee options are available. Please contact your local Bauder Area Technical Manager for more information. |
Uniclass | |
CAWS | J31/120 Warm deck roof coating J31/10 Warm deck roof coating |
Product range |
System performance | Warm roof system. |
Preparation | |
Horizontal work | Bauder SA Bonding Primer.Guidance for specification option: Only for concrete decks. Used to seal substrate and improve adhesion. Bauder Activator Primer.Guidance for specification option: A synthetic rubber resin-based material using a non-flammable solvent and propellant system. Bauder Activator-Primer has been specifically developed to provide the necessary preparation of substrates, insulations and underlayers prior to the installation of Self-Adhesive membranes. |
Skirtings and vertical work | Relevant LiquiTOP Primer.Guidance for specification option: Upstands and details to be primed first.
Purpose: Relevant Bauder LiquiTOP Primer substrate primer to seal and prepare dry surfaces of a variety of common substrate material prior to the application of receiving the new Bauder Cold Applied Liquid Waterproofing System to upstands and details only. The following primers must be used as required:
Application: Refer to the current relevant Bauder LiquiTOP Primer product datasheet. Note: For other substrates, consult the Bauder Technical Department for required preparation methods and priming. |
Air and vapour control layer | TEC DBR 06.Guidance for specification option: Suitable substrates: Metal, plywood and oriented strand board (OSB). Not suitable for concrete decks. Self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with an aluminium foil facing for vapour impermeability. The bottom is a peel off release film, covering self-adhesive bitumen. The product is thinner than other Bauder air and vapour control layers and is therefore lightweight. For mechanically fixed insulation only.
KSD FBS.Guidance for specification option: Suitable substrate: Concrete. Robust, self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with a mica finished upper surface to allow easy bonding of insulation using appropriate Bauder Insulation Adhesive. One side lap features an 80 mm wide glass fleece along the underside, and a 100 mm strip of aluminium foil above. The other side lap has a thermofusible film on the top surface. This arrangement ensures that laps are heat sealed using hot air or gas torch as appropriate to extrude a bitumen bead, thus ensuring waterproofing integrity.
Manufacturer guidancePlease consult Bauder for any other deck types not listed and their suitability. |
Insulation | |
Type | PIR FA-TE Flatboard Insulation.Guidance for specification option: Insert required thickness.
BauderPIR FA G16 foil-faced tapered insulation.Guidance for specification option: Insert required thickness.
Manufacturer guidanceU-Values vary depending on thickness and product, consult literature for details. |
Carrier membrane | |
Type | DBR 06 Carrier membrane. |
Liquid-applied waterproofing | |
Type | Bauder LiquiTOP PU, two coats.Guidance for specification option: First/ embedment coat and top coat to be applied with a roller or brush at a minimum rate of 1 L/m². |
Reinforcement | Bauder LiquiTOP Glass Fibre Mat. |
System accessories | Bauder GRP Water Check Trim.Guidance for specification option: GRP roof edge trim for use with Bauder Cold Applied Liquid Waterproofing systems where the system is terminated at perimeter details, such as watercheck kerbs or parapets.
Internal jointing sleeves and 90° pre-formed angles also available. Note: Bauder GRP Water Check Trim to be used on parapets and perimeter kerbs wider than 200 mm – must not be used on its own as a check kerb. Bauder 100/60 GRP Trim Angle.Guidance for specification option: GRP roof edge trim for use with Bauder Cold Applied Liquid Waterproofing systems where the system is terminated at perimeter details, such as drip edges, watercheck kerbs or parapets.
Note: The trim may be used either way round as required.
- The trims must be bedded in Bauder Sealant and mechanically fixed with corrosion resistant flush headed screws. - Fixings centres must be no greater than 300mm with fixings within 50mm of the ends. In high wind risk areas or above 10m high, fixing centres are to be at no more than 150mm. - The new trim must cover any open joint, which may exist between the kerb and the top of the wall by a distance of minimum 20mm. - The reinforced Bauder LiquiTOP System is to be dressed over the trim to its full extent and past the edge of the downward facing edge. Once the system has cured, the excess is to be trimmed off to a neat finish. BauderPVC ABL-R 75, vertical outlets.Guidance for specification option: Flow rate 4.6 L/s (including leaf guard). Suitable for installation into a downpipe size of 75mm.
Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department. Available separately is the Bauder Leaf Guard for Rigid PVC Outlets. BauderPVC ABL-R 110, vertical outlets.Guidance for specification option: Flow rate 5.5 L/s (including leaf guard). Suitable for installation into a downpipe size of 110mm.
Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department. Available separately is the Bauder Leaf Guard for Rigid PVC Outlets. BauderPVC ABL-R 160, vertical outlets.Guidance for specification option: Flow rate 6.6 L/s (including leaf guard). Suitable for installation into a downpipe size of 160mm.
Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department. Available separately is the Bauder Leaf Guard for Rigid PVC Outlets. BauderSYN KFK-R UNI universal leaf guard for vertical outlets.Guidance for specification option:
This Bauder Leaf Guard is designed to fit into Bauder Rigid PVC rainwater outlets. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department. BauderPVC NLF-R 50 emergency overflow.Guidance for specification option: An extruded PVC emergency overflow outlet compatible with Bauder LiquiTOP.
Bauder Lightning Conductor Clips.Guidance for specification option:
The commissioning of the lightning conductor is to be carried out by a specialist company in conjunction with the roofing contractor. Bauder Rooflights.Guidance for specification option: Applicable to both Insulated and Waterproofing systems. None. |
Fire performance | To DD CEN/TS 1187 (test 4)/ EN 13501-5, BROOF(t4). |
Colour: | Dark Grey RAL 7011. Guidance for specification option: LiquiTOP PU Dark Grey (Approx. RAL 7011) is suggested as the top layer. Mist Grey RAL 7040. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidancePlease refer to EPD on the Bauder website. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 3 | |
- | 1 |
BBA Agrément Certificate
Certificate: Bauder LiquiTOP 3COAT System 20/5789
BBA Agrément Certificate
Certificate: Bauder LiquiTOP 3Coat System Cold Applied Liquid Roof Waterproofing 20/5789
BBA Agrément Certificate
Certificate: Bauder LiquiTOP System 20/5789
EPD
Environmental Product Declaration - (LiquiTOP) Products based on polyurethane or silane-modified polymer, group 4 EPD-FEI-20220108-IBG1-EN
Bauder Activator-Primer (Canister) APR01 - black
Bauder LiquiFIBRE
Bauder LiquiTOP General Purpose Primer
Bauder LiquiTOP Glass Fibre Mat
Bauder LiquiTOP PU
BauderPIR FA G16 Tapered Insulation
BauderPIR FA-TE Flatboard Insulation
BauderPIR GFS G16 Tapered Ridge Infills
BauderPIR KFS G16 Tapered Valley Infills
Bauder PU Insulation Adhesive - Tin
Bauder Quartz
Cold Applied Liquid Systems - Bauder brochure
New Build Flat Roof Solutions - Bauder brochure
Refurbishment Flat Roof Solutions - Bauder brochure