Fast-curing polymethyl methacrylate (PMMA) resin system reinforced with polyester fleece, suitable for both new build or refurbishment applications for cold, warm and inverted constructions.

Jump to:
+44 (0)1473 257671 Website

Application

LiquiTEC is a fast-curing, two-coat, wet-on-wet system particularly suited to areas where there is a high degree of detailing, or when access to install waterproofing is restricted.

Description

Cold liquid-applied, inverted roof system suitable for new build, refurbishment and green roof applications. It is compatible with most existing waterproofing products, making it suitable for use as an overlay system. The system is appropriate for both new build or refurbishment applications for cold, warm, and inverted roof constructions. The system can be used as exposed roof waterproofing or as a roof terrace when protected by hard landscaping as well as extensive and intensive green roof systems. The system can be used in zero falls applications in protected roof situations.

 

Plus points:

  • Totally cold applied minimum 1.8 mm dry film thickness.
  • Polyester reinforced wet-on-wet seamless application.
  • FLL approved root resistance for green roofs.
  • Suitable for roofs with a high degree of detailing.
  • Comprehensive range of guarantee packages.

 

Verified properties:

  • CCPI Verification 0007700032/1125: This system CCPI mark provides accuracy of data delivering assurance to specifiers.
  • BBA Certificate 14/5152.
  • Fire classification BROOF(t4) to BS EN 13501-5 tested to TS 1187 test 4 for external fire exposure on defined permutations of product build up.
  • Fire properties – membranes deemed “unrestricted” in certain circumstances as categorised in BBA certificate.
  • Service life > 25 years.
  • EPD Certification: LiquiTEC Products, Insulation.

General information

Color

Grey

Guidance for specification option:

LiquiFINISH, Blue grey (RAL 7031).

LiquiFINISH, Stone grey (RAL 7030).

LiquiFINISH, Traffic grey (RAL 7043).

Manufacturer guidance

Bauder LiquiDEK is Blue Grey (RAL 7031).

Finish

Smooth

Material

Polymethyl methacrylate (PMMA)

Manufacturer guidance

Liquid applied polymethyl methacrylate membrane.

Shape

Formless

Guidance for specification option:

Liquid.

Warranty description

-

Manufacturer guidance

A comprehensive range of guarantee options are available. Please contact your local Bauder Area Technical Manager for more information.

Uniclass

Ss_30_40_30_42 Liquid-applied inverted roof covering systemsPrimary

CAWS

J31/130 Inverted roof coating

J31/12 Inverted roof coating

Specification data - Liquid-applied inverted roof covering systems

Preparation

-

Horizontal work

Bauder LiquiPRIME 1.

Guidance for specification option:

A cold liquid-applied, fast-curing primer, for use when installing the Bauder LiquiTEC system over timber, asphalt, and bitumen-based substrates. The product is a poly(methyl methacrylate) (PMMA)-based resin, and requires the addition of a catalyst to trigger curing. It is solvent, isocyanate and halogen-free, minimizing its environmental impact.

  • Colour: Clear.
  • Coverage: 0.4 kg/m² (minimum).
  • Application temperature: 0–35°C.
  • Application method: Roller.
  • Rainproof time: 30 minutes (approximate).
  • Overcoat/ traffic time: 45 minutes (approximate).


Bauder LiquiPRIME 2.

Guidance for specification option:

A cold liquid-applied, fast-curing primer, for use when installing the Bauder LiquiTEC system over brick, block and cementitious-based substrates. The product is a poly(methyl methacrylate) (PMMA)-based resin, and requires the addition of a catalyst to trigger curing. It is solvent, isocyanate and halogen-free, minimizing its environmental impact.

  • Colour: Clear.
  • Coverage: 0.4 kg/m² (minimum).
  • Application temperature: 0–35°C.
  • Application method: Roller.
  • Rainproof time: 30 minutes (approximate).
  • Overcoat/ traffic time: 45 minutes (approximate).

Skirtings and vertical work

As 'Horizontal work'.

Liquid-applied waterproofing

-

Type

LiquiDEK, Blue grey (RAL 7031).

Guidance for specification option:

As standard. Cold liquid-applied, fast-curing waterproofing resin.

LiquiFINISH, Stone grey (RAL 7030).

Guidance for specification option:

A fast curing cold applied liquid final coat. 

LiquiFINISH, Traffic grey (RAL 7043).

Guidance for specification option:

A fast curing cold applied liquid final coat. 

LiquiFINISH, Blue grey (RAL 7031).

Guidance for specification option:

A fast curing cold applied liquid final coat. 

Manufacturer guidance

LiquiDEK:

A cold liquid-applied, fast-curing waterproofing resin, for use on the main roof area of the LiquiTEC Roof/ Terrace system. It is applied in two coats, ‘wet-on-wet’, with a layer of Bauder 110 g/m² reinforcement fleece fully embedded in the first coat. The product is a poly(methyl methacrylate) (PMMA) based resin, and requires the addition of a catalyst to trigger curing. It is solvent, isocyanate and halogen-free, minimizing its environmental impact.

  • Coverage: 3 kg/m² (minimum).
  • Application temperature: -5 to +35°C.
  • Application method: Roller.
  • Rainproof time: 30–90 minutes.
  • Overcoat/ traffic time: 45–120 minutes.

Reinforcement

Bauder 110 g Reinforcement Fleece.

Insulation

-

Type

Bauder JFRI PREMIUM+ Inverted Insulation.

Guidance for specification option:

Insert required thickness, 85–240 mm in 5 mm increments.

 

Designed specifically for inverted roof applications.

  • Type: High-performance, rigid expanded polystyrene (EPS) insulation boards.
  • Facing: Unfaced.
  • Colour: Grey.
  • Nominal weight: 30 kg/m³.
  • Standard board size: 1215 x 1215 mm (including 15 mm rebate).
  • Thermal conductivity: Declared 0.031 W/m·K; design 0.031 W/m·K (may vary, dependent on thickness specified).
  • Design load compressive strength: 0.20 N/mm² with 10% nominal compression.
  • Ozone depletion potential (ODP): Zero.
  • Global warming potential (GWP): <5 kg CO² eq/kg.
  • Recyclability: 100%.

 

Consult manufacturer's literature for further details.

Bauder JFRI PREMIUM (300) Inverted Insulation.

Guidance for specification option:

Insert required thickness, 90–240 mm in 5 mm increments.

 

Designed specifically for inverted roof applications.

  • Type: High-performance, rigid expanded polystyrene (EPS) insulation boards.
  • Facing: Unfaced.
  • Colour: White.
  • Weight: 40 kg/m³.
  • Standard board size: 1215 x 1215 mm (including 15 mm rebate).
  • Thermal conductivity: Declared 0.033 W/m·K; design 0.033–0.035 W/m·K (may vary, dependent on thickness specified and application).
  • Design load compressive strength: 0.30 N/mm² with 10% nominal compression.
  • Ozone depletion potential (ODP): Zero.
  • Global warming potential (GWP): <5 kg CO² eq/kg.
  • Recyclability: 100%.

 

Consult manufacturer's literature for further details.

Bauder XPS (300) Inverted Insulation Flatboard.

Guidance for specification option:

Insert required thickness.

 

  • Type: High performance rigid extruded polystyrene insulation boards.
  • Facing: Smooth self-finished.
  • Density: 30 kg/m³.
  • Standard board size: 1250 x 600 mm.
  • Board thickness: 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 80 mm, 100 mm, 120 mm, 140 mm.
  • Thermal conductivity: 30 mm: 0.034 W/m·K; 40–50 mm: 0.035 W/m·K; >50 mm: 0.036 W/m·K.
  • Compressive strength: 0.30 N/mm².
  • Ozone depletion potential (ODP): Zero.
  • Global warming potential (GWP): <1 kg CO² eq/kg.

Bauder XPS (500) Inverted Insulation Flatboard.

Guidance for specification option:

Insert required thickness.

 

  • Type: High performance rigid extruded polystyrene insulation boards.
  • Facing: Smooth self-finished.
  • Density: 35 kg/m³
  • Standard board size: 1250 x 600 mm. Standard board size: 1250 x 600 mm.
  • Board thickness: 40 mm, 50 mm, 60 mm, 70 mm, 80 mm, 100 mm, 120 mm, 140 mm.
  • Thermal conductivity: 40–60 mm: 0.034 W/m·K; >60 mm 0.036 W/m·K.
  • Compressive strength: 0.50 N/mm².
  • Ozone depletion potential (ODP): Zero.
  • Global warming potential (GWP): <1 kg CO² eq/kg.

Fixing

Loose laid (and suitably ballasted).

Guidance for specification option:

  • Setting out: Loose lay insulation directly on to the filter fleece over the waterproofing to brick pattern with staggered joints. Minimize cutting and avoid small pieces at perimeters and penetrations. Dependent upon the total thickness required, it may be necessary to construct the insulation using two layers of board. The manufacturer/supplier can advise on the available combination options.
  • Joints: Butt together.
  • Loading over inverted insulation (minimum): Ballast (landscaping) should be installed onto the Bauder WFRL Membrane (Water Flow Reducing Layer) to a minimum depth required to achieve a permanent minimum 80 kg/m² and load which prevents wind uplift and flotation of the insulation in high winds and/or heavy rainfall.
  • Additional loading at perimeters: On high buildings in more exposed areas, wind uplift may be a problem and in these instances paving slab ballast must be considered. Paving slabs should be a minimum of 50 mm thick. The slabs should be laid on paving slab supports of minimum 175 mm diameter (or equivalent base area).
  • All final details must to be confirmed with Bauder before proceeding.

Water control layer

Bauder JFRI WFRL.

Guidance for specification option:

Flexible and breathable sheet of polypropylene strands randomly spun-bound together, supplied as part of the JFRI Inverted Insulation system. Supplied as part of the JFRI Inverted Insulation system to minimize water flow through and below the insulation.

  • Width: 3 m.
  • Length: 100 m.
  • Thickness: 0.45 mm.
  • Weight: 0.1 kg/m².
  • Colour: Black.


Bauder XPS WFRL.

Guidance for specification option:

Flexible and breathable geotextile membrane of polypropylene strands randomly spun-bound together, supplied as part of the Bauder XPS GG Inverted Insulation system. Supplied as part of the XPS GG Inverted Insulation system to minimize water flow through and below the insulation.

  • Width: 3 m.
  • Length: 100 m.
  • Thickness: 0.17 mm.
  • Weight: 0.06 kg/m².
  • Colour: White.


Manufacturer guidance

Water Flow Reducing Layer/ Vapour Permeable Membrane.


Designed to minimize water flow through and below the insulation, therefore improving thermal performance.

System accessories

Not required.

Bauder 100/60 GRP Trim Angle.

Guidance for specification option:

GRP roof edge trim for use with Bauder Cold Applied Liquid Waterproofing systems where the system is terminated at perimeter details, such as drip edges, watercheck kerbs or parapets.

 

  • Length: 3 m.
  • Face depth: 60 mm.
  • Fixing arm: 100 mm.


Note: The trim may be used either way round as required.


  • Thickness: 2 mm.
  • Colour: Black.


Installation:

  • The trims must be bedded in Bauder LiquiPASTE and mechanically fixed with corrosion resistant flush headed screws.
  • Fixings centres must be no greater than 300 mm with fixings within 50 mm of the ends. In high wind risk areas or above 10 m high, fixing centres are to be at no more than 150 mm.
  • The new trim must cover any open joint, which may exist between the kerb and the top of the wall by a distance of minimum 20 mm.
  • The reinforced Bauder LiquiTEC System is to be dressed over the trim to its full extent and past the edge of the downward facing edge. Once the system has cured, the excess is to be trimmed off to a neat finish.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing, for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass-reinforced plastic (GRP) alternative to a lead counterflashing, for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are specially designed, secure clips that allow for movement.

 

  • Bauder Lightning conductor – Type 4: polyvinyl chloride (PVC)-coated or bare conductor. Bonded in LiquiPASTE, a PMMA-based resin that requires the addition of catalyst to trigger curing.

Bauder LiquiDETAIL (Blue grey RAL 7031).

Guidance for specification option:

Cold liquid-applied, fast-curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing, and is solvent, isocyanate and halogen-free.


Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

 

  • BauderDOME Rooflight.
  • Bauder Euroglaze Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight.
  • Bauder Fire Rated Rooflight.


BauderPVC ABL-R PVC Rigid Outlet.

Guidance for specification option:

A rigid PVC outlet that can be used with Bauder LiquiTEC and LiquiTOP cold-applied liquid systems.

Separation layer

BauderGREEN FV 125 Filter Fleece.

Sustainability data

Contains Red List materials

No

Country of material origin

Germany

Country of product manufacture

Germany

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

Please refer to EPD on the Bauder website.

Third party certifications

Third party certifications

CCPI System

CCPI System

Bauder LiquiDEK Roof System CCPI

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: LiquiTEC Roof Systems 14/5152

EPD

EPD

Environmental Product Declaration - (LiquiTEC) PMMA resin products EPD-DBC-20190116-IBE1-EN

EPD

EPD

BREGENEPD000394 - EPD - JFRI

EPD

EPD

BREGENEPD000395 - EPD JFRI PREMIUM (300)

Literature

BauderPVC ABL-R 75 Vertical outlet

BauderPVC ABL-R 75 Vertical outlet

BauderPVC ABL-R 160 Vertical outlet

BauderPVC ABL-R 160 Vertical outlet

BauderPVC ABL-R 110 Vertical outlet

BauderPVC ABL-R 110 Vertical outlet

BauderPVC NLF-R 50 emergency overflow - Technical Data Sheet

BauderPVC NLF-R 50 emergency overflow - Technical Data Sheet

Bauder 110g Reinforcement Fleece

Bauder 110g Reinforcement Fleece

Bauder LiquiDEK

Bauder LiquiDEK

Bauder LiquiDETAIL

Bauder LiquiDETAIL

Bauder LiquiFIBRE

Bauder LiquiFIBRE

Bauder LiquiFINISH

Bauder LiquiFINISH

Bauder Quartz

Bauder Quartz

Bauder waterproofing systems are now CCPI verified.

Bauder waterproofing systems are now CCPI verified.

Cold Applied Liquid Systems - Bauder brochure

Cold Applied Liquid Systems - Bauder brochure

CPD Seminars - Bauder

CPD Seminars - Bauder

Flat Roof Design Considerations - Bauder

Flat Roof Design Considerations - Bauder

New Build Flat Roof Solutions - Bauder brochure

New Build Flat Roof Solutions - Bauder brochure

Refurbishment Flat Roof Solutions - Bauder brochure

Refurbishment Flat Roof Solutions - Bauder brochure

Bauder LiquiPRIME 1 - Technical Data Sheet

Bauder LiquiPRIME 1 - Technical Data Sheet

Bauder LiquiPRIME 2 - Technical Data Sheet

Bauder LiquiPRIME 2 - Technical Data Sheet

Bauder Catalyst - Technical Data Sheet

Bauder Catalyst - Technical Data Sheet

Case studies

Morris Blitz Court

Morris Blitz Court