VES-A00-P (with LEDs)
Aspirating smoke detector with a valve mechanism in the inlet manifold, and software to indicate which pipe has detected smoke.
Suitable for a range of application areas, for example:
Aspirating smoke detector with a valve mechanism in the inlet manifold, and software to indicate which pipe has detected smoke.
This configuration enables a single zone to be divided into four separate sectors, for example, distinguishing between separate aisles within a data room. The VES enables the user to locate the source of smoke by identifying the first sector to reach the alert level. The detector then continues to sample from all sectors to monitor fire growth and will report separate alarm levels for each sector. The VES provides four individually configurable alarm levels (Alert, Action, Fire 1 and Fire 2) for each sector allowing optimum protection in a wide range of applications. Built on the flair detection technology and years of application experience, VES detectors achieve consistent performance over their lifetime via absolute calibration. In addition, the VES delivers a range of revolutionary features that provide user value.
Features and benefits:
Color | Black |
Material | Plastic |
Shape | Rectangle |
Length | 135 mm Manufacturer guidanceDepth. |
Width | 350 mm |
Height | 225 mm |
Uniclass | |
CAWS | W90/328 Point smoke detectors |
SKU Code | VES-A00-P |
Classification data | |
Standard | To BS EN 54-20. Guidance for specification option: & ISO 7240-20. |
Third-party certification | CSFM, FM, ActivFire, VdS, and NF-SSI-approved. |
Sensitivity class | To BS EN 54-20, Class A. Guidance for specification option: 40 holes / Fire 1 = 0.067% obs/m. To BS EN 54-20, Class B. Guidance for specification option: 80 holes / Fire 1 = 0.085% obs/m. To BS EN 54-20, Class C. Guidance for specification option: 100 holes / Fire 1 = 0.251% obs/m. |
Sampling pipe | |
Arrangement | Double-pipe. Guidance for specification option: 2 pipes. 100 m. Triple-pipe. Guidance for specification option: 3 pipes. 80 m. Four-pipe. Guidance for specification option: 4 pipes. 70 m. Manufacturer guidance
|
Length (maximum) | 560 m. |
Air inlet holes (maximum) | 40. Guidance for specification option: For Class A. 80. Guidance for specification option: For Class B. 100. Guidance for specification option: For Class C. |
Coverage (minimum) | 2000 m². |
Enclosure | |
Material | Plastic. |
Ingress protection (minimum) | IP 40. |
Power supply | 24 V d.c. |
Controls | |
Display type | Light-emitting diode display (LED). |
Functions | Four alarm thresholds (two pre-alarms and two alarms). On board memory capable of recording 20 000 events. Guidance for specification option: Event log: Up to 20 000 events. Smoke level and alarm threshold levels, user actions, alarms and faults with time and date stamp. AutoLearn: Detector learns Alarm Thresholds and Flow Fault thresholds by monitoring the environment. |
Display the following information | Alert, Action, Fire 1 and Fire 2. Disabled. Fault. Power. Guidance for specification option: Threshold setting range:
|
Relay contacts | 12 no. 2 A/ 30 V d.c. programmable relays. Guidance for specification option: Configurable as latching or non-latching. |
Weight | 4.7 kg. |
Power consumption | Aspirator setting 1: Quiescent: 7.5 W; In alarm: 8.4 W. Aspirator setting 5: Quiescent: 9.8 W; In alarm: 10.8 W. Aspirator setting 10: Quiescent: 15.4 W; In alarm: 15.8 W. |
Operating temperature | Ambient: 0–38°C. Sampled air: -20 to +60°C. |
Operating humidity | 5–95% RH, non-condensing. |
SoftwareVersion | Xtralis VSC/ ASPIRE. |
Sensitivity | 0.005 to 20% obs/m. |
Cable | 4 x 26 mm cable entries. Guidance for specification option: Cable terminations: Screw terminal blocks. |
Communications | VESDAnet. |
Accessories | Not required. Power supply unit - VPS-250-STX5-SLV. Guidance for specification option: These are the deeper units designed for installation with a VESDA-E detector (at all fan speeds). The internal charger is EN 54-4 certified and is rated to provide a 3 A continuous 24 V d.c. supply. There is space for up to 24 Ah batteries (not provided). The unit also provides a non-certified setting which enables it to power loads up to 3.4 A while recharging batteries up to 24 Ah in accordance with EN 54-4. Power supply unit - VPS-250-STX5. Guidance for specification option: These are the deeper units designed for installation with a VESDA-E detector (at all fan speeds). The internal charger is EN 54-4 certified and is rated to provide a 3 A continuous 24 V d.c. supply. There is space for up to 24 Ah batteries (not provided). The unit also provides a non-certified setting which enables it to power loads up to 3.4 A while recharging batteries up to 24 Ah in accordance with EN 54-4. Power supply unit - VPS-220-STX5-SLV. Guidance for specification option: These are the shallower units in the range with depth and width matching the VESDA-E detectors. Internally, they provide an EN 54-4 certified Power Supply rated to provide a 0.5 A continuous 24 V d.c. supply whilst also charging the batteries (not supplied) which can be a 7, 12 or uniquely, 14 Ah arrangement. As such the unit can be used with confidence to power, and provide 24 hr standby (plus 0.5 hr in alarm), for the VESDA VLF-500, VESDA-E VEP & VESDA-E VES detectors and also the VESDA-E VEU detectors up to fan speed 5. The unit also provides a non-certified setting which enables it to power loads up to 1A while recharging batteries up to 12 Ah in accordance with EN 54-4. Power supply unit - VPS-220-STX5. Guidance for specification option: These are the shallower units in the range with depth and width matching the VESDA-E detectors. Internally, they provide an EN 54-4 certified Power Supply rated to provide a 0.5 A continuous 24 V d.c. supply whilst also charging the batteries (not supplied) which can be a 7, 12 or uniquely, 14 Ah arrangement. As such the unit can be used with confidence to power, and provide 24 hr standby (plus 0.5 hr in alarm), for the VESDA VLF-500, VESDA-E VEP & VESDA-E VES detectors and also the VESDA-E VEU detectors up to fan speed 5. The unit also provides a non-certified setting which enables it to power loads up to 1A while recharging batteries up to 12 Ah in accordance with EN 54-4. ASD Sampling Hole Clips. Refrigerated Storage Sampling Kit - VSP-860. Tamper Proof Sampling Point. Flush Mount Sampling Point. Filter - VSP-962. Xtralis In-Line Filter. Automatic Purging Unit - F-BO-AFE70. VESDA High Level Interface (HLI). VESDA Remote Display Module. VESDA 19" Sub Rack. VESDA LCD Programmer. Smoke Pen. Manufacturer guidanceSpare parts are also available - consult manufacturer for details. |
Material | Plastic |
Addressable Aspirating Smoke Detector - VESDA-E VEA - Aspirating Smoke Detector
Aspirating Smoke Detector - VESDA Laser Industrial (VLI) - Aspirating Smoke Detector
Aspirating Smoke Detector - VESDA LaserFocus (VLF) - Aspirating Smoke Detector
Aspirating Smoke Detector - VESDA-E VEP - Aspirating Smoke Detector
Aspirating Smoke Detector - VESDA-E VEU - Aspirating Smoke Detector
FAAST FLEX™ - Aspirating Smoke Detector - Aspirating Smoke Detector