Concrete-to-concrete, thermally-insulated, balcony connectors.
Suitable for highly energy-efficient structures, heavily-congested or stepped floor slabs, applications where maximum corrosion protection is required and when an integral fire resistance is preferred to the installation of a separate fire protection barrier.
High-performance, thermally-broken connectors for concrete-to-concrete balcony applications.
Each unit consists of non-deformable cage offering high rigidity and dimensional stability. The insulation component comprises Rockwool® mineral wool that offers inherent fire-resistant qualities.
Features and benefits:
Color | Silver |
Material | Stainless steel |
Uniclass | |
CAWS | E30/240 Proprietary prefabricated reinforcement E30/250 Proprietary prefabricated continuity reinforcement strips E42/335 Shear Load Connectors |
Product range |
Anchors | |
Configuration | Not applicable.SB.Guidance for specification option: For ACTP-MV only. SH.Guidance for specification option: For ACTP-MV only. WB.Guidance for specification option: For ACTP-MV only. WBH.Guidance for specification option: For ACTP-DV only. WBTT.Guidance for specification option: For ACTP-V only WH.Guidance for specification option: For ACTP-MV only. |
Product Reference | Ancon Isotec Balcony Connectors |
Type | ACTP-DMV. ACTP-DV. ACTP-MV. ACTP-V. Manufacturer guidance
|
Height | Guidance for specification option: Insert height. Available in 160–250 mm heights to match slab depth. |
Length | 500 mm 1000 mm |
Accessories | None Corner profile |
Density | 100 kg/m³. |
ThermalConductivity | 0.18–0.3 W/mK depending on construction. |
Fire resistance | 120 minutes as assessed by CSTB. |
Reinforcement | Tensile and shear reinforcement consist of 1.4301 or 1.4362 highly corrosion-resistant stainless steel with a minimum characteristic strength Rp0.2 of 500 N/mm². Tensile bars are continuous with no structural welding or point of weakness. Compression studs are manufactured from 12 mm diameter, high-resistance 1.4301 stainless steel bars with hot-forged heads. |
Anchorage type | Not applicable SB Guidance for specification option: For ACTP-MV only. SH Guidance for specification option: For ACTP-MV only. WB Guidance for specification option: For ACTP-MV only. WBH Guidance for specification option: For ACTP-DV only. |
Insulation | Fire-resistant Rockwool® mineral wool insulation is protected by a stainless steel U-shaped profile top and bottom. A label is affixed to the top identifying the system type and direction of placement. |
Thickness | 80 mm. |