Verified by manufacturer 10 months ago
Single Leaf: Anodized.
Secured By Design
Certificate type
QA Certificate
Certificate type
Aluminium residential hinged door system.
Suitable for use with residential new build and refurbishment projects, ideal for light and medium traffic environments.
Aluminium residential hinged door system.
Features and benefits:
Color | Other Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized To a minimum 15 micrometres thickness. Powder-coated |
Material | Aluminium Glass |
Shape | Rectangle |
WidthRecommended size limits (maximum). | 1000 mm Single leaf: hardware limits. 1020 mm Single leaf: tested limits. 2200 mm Double leaf: tested limits. 2400 mm Double leaf: hardware limits. |
HeightRecommended size limits (maximum). | 2160 mm Single leaf: tested limits. 2200 mm Single leaf: hardware limits. 2250 mm Double leaf: tested limits. 2400 mm Double leaf: hardware limits. |
Uniclass | |
CAWS | L20/480 Doorsets L20/55 Doorsets |
Product range |
Configuration | Single leaf, open in.Single leaf, open out. |
Doorset size | 1000 x 2200 mm.Maximum size: hardware limits. 1020 x 2160 mm.Maximum size: tested limits. As drawing.Insert reference. As schedule.Insert reference. |
Performance | - |
Thermal | 1.4 W/m²K. |
Intruder resistance | - |
Minimum requirement | Secured by Design certification and PAS 24. |
Frame | - |
Material | Aluminium. |
Threshold | As drawing.Low threshold.Optional with a 15 mm step height to meet Building Regulations (E&W) Approved Document M. |
Finish | - |
Coating | Anodized.To a minimum 15 micrometres thickness. |
Texture | Not applicable. |
Colour | Anodized. |
Door leaf | - |
Core | Manufacturer's standard. |
Material | Aluminium. |
Glazing | - |
Type | Glass panels.22–40 mm glass look-a-like panels, insert requirements. Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing. Glazing.22–40 mm insulating glass units, insert requirements. Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.22–40 mm insulated sandwich panels, insert requirements. Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Beading | - |
Type | Chamfered.Square. |
Material | Aluminium. |
Finish | - |
Coating | Anodized.To a minimum 15 micrometres thickness. |
Texture | Not applicable. |
External colour | Anodized. |
Internal colour | Anodized. |
Film thickness (minimum) | 15 micrometres. |
Accessories | Not required.AW720.Integral corner post, for 70 mm frame. AW721.Integral corner post, for 58 mm frame. AW724.20 mm frame extender, for 70 mm frame. AW725.20 mm frame extender, for 58 mm frame. AW728.40 mm frame extender, for 70 mm frame. Fanlight.Insert requirements. Laybar.Insert requirements. Letterplate.Insert requirements. Midrail.Insert requirements. Sidelight.Insert requirements. |
Outer frame | AW602. 70 mm standard ovolo frame. AW603. 58 mm odd leg frame. AW604. 58 mm slim frame. AW605. 58 mm standard frame. AW607. 70 mm deep ovolo frame. |
Vent | AD200. Open in. AD201. Open out. AD300. Floating mullion. |
Coupler | Not required. AW702. 15 mm coupler, for 70 mm frame. AW703. 15 mm coupler, for 58 mm frame. AW705. 26 mm coupler, for 70 mm frame. AW706. 26 mm coupler, for 58 mm frame. |
Sub sill | Not required. AD100. Low threshold. AW542. 150 mm sill. AW543. 177 mm sill. AW544. 190 mm sill. |
Panel weightMaximum panel weight. | 67.5 kg. 90 kg. |
Air permeability | Class 4 (600 Pa). |
Watertightness | Class 7A (300 Pa). |
Wind resistance | E2400 (2400 Pa). |