Aluclad Rainscreen Cassette Interlock System
CWCT Certificate
Certificate type
Fire Safety Certification
Certificate type
Aluminium rainscreen cassette system.
Compatible with an extensive range of standard and project specific architectural fabrications to suit wide ranging applications.
Cassette Discrete Fix System (fixed with fasteners through the panel flanges in the joint recess) or Cassette Interlock System (hooking-on) solid aluminium rainscreen panels produced using non-combustible material and available in A1/ A2 fire rated finishes, enabling architects, designers, building owners and installers to choose from a range of options.
Aluclad Cassette panels, solid or perforated, can be supplied in various panel lengths and finished in anodized or polyester powder coated finishes in an extensive range of colours, to give a distinct appearance to the facade of a project.
Features and benefits:
Color | Other Guidance for specification option: Available in any RAL, BS, wood effect, GRC, stone effect or bespoke colour options. Beige Black Blue Brown |
Finish | Powder-coated Anodized PVdF |
Material | Aluminium Stainless steel Steel Guidance for specification option: Galvanized. |
Shape | Rectangle Guidance for specification option: Standard panel sizes used in manufacturing:
|
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 12 year Guidance for specification option: PPC Qualicoat 1. 25 year Guidance for specification option: 25 years if PPC Qualicoat 2 or anodized. Manufacturer guidanceWarranties subject to cleaning and maintenance strategy. |
Uniclass | |
CAWS | H20/10 Sheet cladding H92/120 Rainscreen cladding |
System performance | CWCT (test methods in accordance with CWCT standard test methods for building envelopes). |
Thermal insulation | Not required.Mineral wool slab insulation (supplied by others). |
Breather membrane | |
Material | Vapour-permeable sheets (supplied by others). |
Fasteners | Manufacturer's standard (supplied by others). |
Secondary support structure | Alucald aluminium bespoke hook-on profile back to Helping Hand Bracket System.Alucald stainless steel bespoke hook-on profile back to Helping Hand Bracket System |
Cavity fire barriers | |
Horizontal | Not required.Fire barrier (supplied by others). |
Vertical | Not required.Fire barrier (supplied by others). |
Cladding panels | |
Material | Aluclad Rainscreen Cassette Interlock System. |
Panel joints | 10–30 mm joints. |
Reveals | Bespoke shape reveals.Manufacturer guidanceConsult manufacturer for further details. |
System accessories | Not required.Flashings.Copings.Trims.Vents.Plenum. |
Fixing system | Interlock (hook on) fixing system. |
Panels | Solid. Perforated. Guidance for specification option: To various patterns. Consult manufacturer for options. |
Surface finish | Polyester powder-coated. PVDF. Anodized. |
Top surface colour | RAL colour. BS colour. Wood effect. GRC. Stone effect. Manufacturer guidanceConsult manufacturer and insert requirements. Available in any RAL, BS, wood effect, GRC, stone effect or bespoke colour options. |
Fire propagation to BS 476-6 | To BS 476 part 6, Class 0. |
Surface spread of flame | To BS 476 part 7, Class 1. |
Thickness | Typical 3 mm Aluminium. |
Panel depth | 25–50 mm. |
Ventilation cavity | Required. Guidance for specification option: Ventilated cavity required as for typical rainscreen cladding. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Aluminium Stainless steel Steel Guidance for specification option: Galvanized. |
Recyclability | 100% |