Verified by manufacturer 26 days ago
FIS Acoustic Verification Scheme
Certificate type
UKAS
Certificate type
Standard single wall system based on 100 mm thick Specwall, A1-rated panel.
Specwall’s A1 panel is developed to provide a high fire rating to that which is currently being provided by blockwork, concrete walls or specialized systems such as SFS. It has all the capabilities of the existing Specwall 100 mm A2 panel, but with improved fire rating performance.
Due to its A1 rating, it is recommended to be used as an external lining where the requirements are more demanding. It is also perfect for use as a shaftwall, core wall, riser wall, smoke shaft, lift shaft, service riser and to replace block walls. It is water permeable and doesn’t break down when submerged in water, making it suitable for pre-build, Cat A and Cat B installs.
Specwall A1 panels are manufactured in a standard size of 3000 x 610 mm. It is only available in 100 mm thickness and can be cut to size.
All joints are PU adhesive bonded and filled with grout. Taping and jointing can be requested by the client.
Features and benefits:
Color | Grey |
Finish | Cement Smooth |
Material | Concrete Cement Fibre cement Composite |
Shape | Rectangle |
Length | Bespoke Guidance for specification option: Maximum: 6000 mm. |
Width | 100 mm |
Height | Bespoke Guidance for specification option: Maximum (unsupported): 6000 mm. |
Warranty description | Ten year |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
System performance | BS EN ISO-1716:2018 - Reaction to fire tests for products — Determination of the gross heat of combustion (calorific value). |
Panel partitioning | Specwall SP-100 A1 panels.Guidance for specification option: Maximum unsupported height: 6000 mm. Panel:
|
Fasteners | Manufacturer's standard.Guidance for specification option: No fasteners required. Screw or dowel for joints, junctions, corners, and wall abutments. Refer to manufacturer's technical manual for guidance. |
Joint treatment | Fully filled with PU adhesive, grout applied to close joints.Guidance for specification option: Refer to manufacturer's technical manual for guidance. |
Joint finish | Grout, tape and fill.Guidance for specification option: Refer to manufacturer's technical manual for guidance. |
System accessories | None.Base track with fixings to suit substrate.Top L angles.Dowel.Guidance for specification option: For corner and/ or T-junction joint finish. 12 x 200 mm, with resin. PU adhesive.Guidance for specification option: For corner and/ or T-junction joint finish. Grout.Guidance for specification option: If required in addition to joint treatment and/ or detail. Intumescent sealant.Rockwool insulation.Guidance for specification option: For use in deflection head in the Specwall between the two angles. |
Samples required | On request. |
Execution | Manufacturer guidanceRefer to Specwall technical manual. |
Fire performance | 180 minutes. |
Fire rating for panels | A1. |
Acoustic performance | 40 dB Rw. |
Thermal transmittance (U-Value) | 2.68 W/m²K. |
Compressive strength (mean value) | 6 MPa. Guidance for specification option: Average after 28 days for single Specwall. |
Contains Red List materials | No |
Country of material origin | United Arab Emirates |
Country of product manufacture | United Arab Emirates |
Material | Concrete Cement Fibre cement Composite |
Manufacturing plant location | |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceUnder process; consult manufacturer for details. |
Recyclability | Specwall A1 panels are fully demountable and reusable, 100% recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 10 % |
Platform | Compatible | Version |
---|---|---|
- | 1 |
FIS Acoustic Verification Scheme
Specwall - FIS Accredited Membership Certificate
UKAS
Specwall - UKAS - Reaction to Fire Test - BS EN ISO-1716:2018 - Specwall A1
UKAS
Specwall - UKTC - Fire Test Report BS EN 1364-1 2015 - Specwall A1
UKAS
Specwall - The Building Test Centre - Acoustic Test Report - BS EN ISO 10140
Specwall A1 Panel Information Sheet
Specwall Mini Brochure
Specwall Performance Chart
Specwall Physical Properties Document
Specwall Repair Guide
Specwall Door Installation Document
Specwall Systems Document
Specwall Technical Manual
Specwall Material Safety Data Sheet
Specwall Training Presentation
Specwall Specpod Brochure
Specwall Alterations Document
Specwall - Connection details (Single wall)
Specwall - Wall types (Single and double walls)
Hybrid Specwall HB001 (Acoustic & fire rated wall panel systems for internal separating walls) - Lightweight Concrete Panel
Hybrid Specwall HB002 (Acoustic & fire rated wall panel systems for internal separating walls) - Lightweight Concrete Panel
Hybrid Specwall HB003 (Acoustic & fire rated wall panel systems for internal separating walls) - Lightweight Concrete Panel
Hybrid Specwall HB004 (Acoustic & fire rated wall panel systems for internal separating walls) - Lightweight Concrete Panel
Hybrid Specwall HB008 (Acoustic & fire rated wall panel systems for internal separating walls) - Lightweight Concrete Panel
Single 100 mm Specwall (SFS, Blockwork Alternative For Shaft, Risers, External And Internal Walls) - Lightweight Single Concrete Panel
Single 75 mm Specwall (SFS, Blockwork Alternative For Shaft, Risers, Internal Walls) - Lightweight Single Concrete Panel
Twin 100mm Specwall (Strong, Durable, Mould resistant Masonry Fire partition walls) - Insulated Twin Concrete Panel
Twin 75mm Specwall (Fire Partition, Robust, High Impact Wall) - Lightweight Twin Concrete Panel