NBS Source
I'm a manufacturer

Compare variants

Aluminium fire-resistant door - ADS 80 FR 60
Aluminium fire-resistant door - ADS 80 FR 60
Aluminium fire-resistant door - ADS 80 FR 60

Verified 15 days ago

Schueco UK Ltd

Verified 15 days ago

Schueco UK Ltd

Verified 15 days ago

Schueco UK Ltd
Summary
Door ADS 80 FR 60 for 60 minute fire resistance.
Digital objects
-
-
Finish
Anodized, Powder-coated
-
-
Material
Aluminium
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Standard
To EN 14351.
-
-
Configuration
Double leaf inward opening.
-
-
Doorset size
-
-
-
Performance
-
-
-
Fire performance
-
-
-
Fire integrity
To BS EN 1634-1, 60 minutes.
-
-
Fire insulation
To BS EN 1634-1, 60 minutes.
-
-
Radiation
To BS EN 1634-1, 60 minutes.
-
-
Smoke control
To BS EN 1634-1, Class Sa / S200.
-
-
Acoustic performance
-
-
-
Thermal
-
-
-
Intruder resistance
-
-
-
Minimum requirement
-
-
-
Frame
-
-
-
Material
Aluminium.
-
-
Finish
-
-
-
Coating
Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
Door leaf
-
-
-
Thickness
80 mm.
-
-
Core
Not applicable., Manufacturer's standard.
-
-
Panel details
Not applicable., Manufacturer's standard.
-
-
Material
Not applicable., Aluminium.
-
-
Glazing
-
-
-
Type
Not required., Required.
-
-
Finish
-
-
-
Coating
As Frame., Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
External colour
As Frame., Other.
-
-
Internal colour
As External., Other.
-
-
Film thickness (minimum)
Manufacturer's standard.
-
-

Additional properties

Durability
Up to 1 million cycles.
-
-
Load
To EN 1191, Class 5.
-
-
Watertightness
Not required.
-
-
Resistance to wind load
Not required.
-
-
Fittings
Fast push-in fixing of the fittings, fixing to the building structure, location of the intumescent strips.
-
-