PowerControl Uninterruptible Power Supply
PowerControl Uninterruptible Power Supply
PowerControl Uninterruptible Power Supply

Verified 3 days ago

Legrand Electric Ltd

Verified 3 days ago

Legrand Electric Ltd

Verified 3 days ago

Legrand Electric Ltd
Summary
A range of uninterruptible power supply (UPS) systems for businesses, institutions and critical infrastructure.
-
-
Application
  • Single phase UPS systems are suitable for smaller scale applications, including offices, retail environments, IT installations and some hospital applications.
  • Three Phase UPS Systems are suitable for safeguarding critical infrastructure, such as data centres, industrial operations, and large-scale networks.
  • Central Power Supply Systems (CPSS) designed to support life safety equipment, including emergency lighting, fire detection systems and safety alarms in public buildings, hospitals, or other critical facilities.
-
-
Description

Legrand offers a comprehensive range of Uninterruptible Power Supply (UPS) systems designed for businesses, institutions and critical infrastructure.

The range includes Single Phase UPS Systems, Three Phase UPS Systems, and Central Power Supply Systems (CPSS).

-
-
Color
Black, White
-
-
Finish
Other
-
-
Material
Other
-
-
Shape
Rectangle
-
-
Length
513 mm, 440 mm, 557 mm, 600 mm, 500 mm, 325 mm, 438 mm, 628 mm, 1000 mm, 940 mm, 970 mm
-
-
Width
440 mm, 170 mm, 414 mm, 600 mm, 900 mm, 560 mm, 880 mm, 1430 mm, 1630 mm
-
-
Height
44 mm, 88 mm, 132 mm, 238 mm, 1370 mm, 1650 mm, 1990 mm, 1500 mm, 1800 mm, 1978 mm
-
-
Warranty description
Two year
-
-
SKU Code
0
-
-

Specification

Classification data
Standards
To BS EN IEC 62040-1, BS EN IEC 62040-2, and BS EN IEC 62040-3.
-
-
Mode of operation
Line-interactive.
-
-
Input
-
-
-
Nominal voltage
Single-phase 230 V a.c.
-
-
Voltage tolerance
+15%/-20%.
-
-
Frequency
50 or 60 Hz +/-0.5%.
-
-
Power factor
Up to 0.9.
-
-
Inverter output
-
-
-
Rated output apparent power
0.75 kV·A., 1 kV·A., 1.5 kV·A., 2.2 kV·A., 3 kV·A.
-
-
Nominal voltage
Single-phase 230 V a.c.
-
-
Voltage waveform
Sinusoidal.
-
-
Total harmonic distortion (THD)
< 3% with linear load.
-
-
Nominal frequency
50 or 60 Hz.
-
-
Frequency tolerance
+/-0.5%.
-
-
Batteries
-
-
-
Location
Within UPS equipment enclosure., Within UPS equipment enclosure, plus extended battery cabinet (RT 2U/3U models).
-
-
Type
VRLA.
-
-
Voltage
12 V.
-
-
Battery autonomy (stored energy time at rated power)
Up to 12 minutes.
-
-
Battery recharge time
-
-
-
To 80% capacity
6–7 hours to 90% capacity.
-
-
Controls, indicators and alarms
-
-
-
Light emitting diode (LED) indication
Three-colored LED bar.
-
-
Communications and signalling
RS232, USB, SNMP slot, EPO, dry contacts.
-
-
Enclosure
-
-
-
Ingress protection (minimum)
IP20.
-
-
Material and construction
-
-
-
Colour
Black.
-
-
Noise emission
-
-
-
Sound pressure level in normal mode (maximum)
< 55 dBA at 1 m.
-
-
Properties
-
-
-
Recycled content
10%.
-
-

Additional properties

Accessories
Not required., 2 Rack support bracket kit for 2U and 3U models., External manual by-pass., 10 A British Standard cable., 16 A British Standard cable.
-
-
Unit size
1U., 2U., 3U.
-
-

Sustainability data

Material
Other
-
-