KESSEL Pumpfix F Backwater Pumping Station up to 4 L/s
KESSEL Pumpfix F Backwater Pumping Station up to 4 L/s
KESSEL Pumpfix F Backwater Pumping Station up to 4 L/s

Last verified by manufacturer over a year ago

IPS Flow Systems

Last verified by manufacturer over a year ago

IPS Flow Systems

Last verified by manufacturer over a year ago

IPS Flow Systems
Summary
Backwater valve with automatic single flap with over pumping that pumps back against the backwater. For use in concrete slab/ floor or in manhole/ exposed pipe.
-
-
Application

Automatic anti-flood valve, for installation in concrete slab/floor or in manhole/ exposed pipe.

Suitable for use with wastewater with or without sewage. Note: without macerator, can be used for continuous operation; consult manufacturer for details.

For applications requiring up to 20 L/s, see KESSEL Ecolift XL.

-
-
Description

Backwater valve with automatic single flap with over pumping that pumps back against the backwater. For use in concrete slab/ floor or in manhole/ exposed pipe.


In normal operation, the Pumpfix F allows the wastewater from the building to flow with gravity into the sewage pipe, making it energy-neutral. In the event of backwater, the backwater flap closes automatically and when wastewater arises this is pumped against the backwater

pressure.

The integrated cutting wheel shreds solids meaning the Pumpfix F is also suitable for use wastewater containing sewage.


Features and benefits:

  • Concrete slab/ floor installation: Polymer construction, with surface-water-tight cover plate, class A 15; integrated floor drain.
  • Exposed wastewater pipe installation: Polymer construction, with protective cover.
  • Installation kit with choice of cover.
  • Backwater valve according to EN 13564 Type 3 with pump (1 kW/ 230 V).
  • Telescopic upper section for continuous height- and level-adjustment.
  • Outer diameter 110 or 160 mm.
  • Can also drain basement staircases up to 5 m².
  • Plug-and-play control unit with connection option to building management system (BMS) and alarm. Protection type IP 54, with integrated self-diagnosis system (SDS), display for operating status and battery back-up. Motor is rated protection Type IP 68 (3 m, 24 h).
  • Extension sections available (concrete slab/ floor models only).
-
-
Color
Black
-
-
Material
Polymer
-
-

Specification

Classification data
Standard
To BS EN 13564-1.
-
-
Classification
Type 3 with pump.
-
-
Form
For installation into concrete slab/ floor, recessed cover for on-site tiling.
-
-
Material
Polymer.
-
-
Connections
Outer diameter: 110 mm.
-
-
Integral accessories
None., Extension section with centre flange., Extension section with flange and counter flange., Extension section with gasket., Cable extension for motor, 10 m., Cable extension for probe, 10 m., Cable extension for pump, 10 m., Multistop hygiene and odour stop., Hair filter., Conversion kit., Testing funnel (maintenance)., Spigot., Socket., Audible alarm., Access code potential-free contact.
-
-