NBS Source
I'm a manufacturer

"ceiling finishes"

5,694 results found

Can't find what you're looking for?

Sort by:

Showing 3457-3492 of 3556

Sponsored
Isocheck Underwood system - Acoustic layer for under a timber floor

Isocheck Underwood system - Acoustic layer for under a timber floor

Verified 3 months ago

Isomass Ltd

Impact improvement of engineered timber floors.
Sponsored
AR-PAVE A1-Rated Aluminium Paving Support System

AR-PAVE A1-Rated Aluminium Paving Support System

Verified over a year ago

Alfresco Floors Ltd

Class A1 fire-rated aluminium paving support system.
Sponsored
Delcote® 25 Architectural Roof Coating for Metal Roofs (25 Year BBA) - Silicone coating

Delcote® 25 Architectural Roof Coating for Metal Roofs (25 Year BBA) - Silicone coating

Verified 1 month ago

HD Sharman Ltd.

Silicone architectural roof coating for metal roofs.
BOS
Sponsored
ZIP Retractable Ladders - For Roof Access

ZIP Retractable Ladders - For Roof Access

Verified over a year ago

Surespan

A retractable loft ladder to suit a variety of heights suitable for industrial and commericial applications. Counter balanced spring for easy operation.
+4
BOS
Sponsored
Curtain Track - Cord Operated  - Silent Gliss SG 3840 Curved - Curtain Track

Curtain Track - Cord Operated - Silent Gliss SG 3840 Curved - Curtain Track

Verified 9 days ago

Silent Gliss Ltd

Cord operated curtain track for light to medium weight curtains. Ceiling or wall fixed. For use in commercial or residential interiors. Available in white and black. Suitable for wave curtains.
Sponsored
Curtain Track - Hand Operated - Silent Gliss SG 6840  - Curtain Track

Curtain Track - Hand Operated - Silent Gliss SG 6840 - Curtain Track

Verified 9 days ago

Silent Gliss Ltd

Hand operated curtain track for light to medium weight curtains. Ceiling or wall fixed. For use in commercial or residential interiors. Available in white and black. Suitable for wave curtains.
BOS
Sponsored
Pearl and Pearl Solo Downlighter Urinal Control

Pearl and Pearl Solo Downlighter Urinal Control

Verified over a year ago

KWC DVS Limited

The Flushmatic urinal control is used for multiple station urinals and can be surface or ceiling mounted, using a passive infrared (PIR) detector.
+16
Sponsored
 Quartzglide 2 - Glass Sliding Door - Glass sliding door, single glazed door

Quartzglide 2 - Glass Sliding Door - Glass sliding door, single glazed door

Verified 1 month ago

Apton Partitioning

Single glazed sliding glass door with concealed runners for unimpeded glass from floor to ceiling partitioning solution.
Sponsored
HD1025 Hush System MF17 Acoustic Floor Solution

HD1025 Hush System MF17 Acoustic Floor Solution

Verified 3 months ago

Hush Acoustics

High performing acoustic system that can be used as a flooring and ceiling solution.
BOS
Sponsored
Flushmatic Downlighter Urinal Control

Flushmatic Downlighter Urinal Control

Verified over a year ago

KWC DVS Limited

The Flushmatic urinal control is used for multiple station urinals and can be surface or ceiling mounted, using a passive infrared (PIR) detector.
+16
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-15Md15dB-100G(250)

Siniat Twin Frame Partition Twin(AB)-CS50R-15Md15dB-100G(250)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-215dB-100G(250)

Siniat Twin Frame Partition Twin(AB)-CS50R-215dB-100G(250)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-215Un-50G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-215Un-50G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(UB)-IS70B-215dB-25G(210)

Siniat Twin Frame Partition Twin(UB)-IS70B-215dB-25G(210)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-215dB-50G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-215dB-50G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS90W-15Md15dB-100G(300)

Siniat Twin Frame Partition Twin(AB)-CS90W-15Md15dB-100G(300)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
BOS
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS90W-315dB-200G(450)

Siniat Twin Frame Partition Twin(AB)-CS90W-315dB-200G(450)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat A1 Shaftwall System – CH90B-19WD#312WD

Siniat A1 Shaftwall System – CH90B-19WD#312WD

Verified 3 months ago

Siniat

Vertical, triple-layer Shaftwall system | A1 Euroclass | EI120
BOS
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-15Un15dB-50G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-15Un15dB-50G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-15Md15dB-50G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-15Md15dB-50G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-215dB#15Sx15dB-50G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-215dB#15Sx15dB-50G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-15Un15dB#15Sx15Un-50G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-15Un15dB#15Sx15Un-50G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS50R-215Ld-25G(200)

Siniat Twin Frame Partition Twin(AB)-CS50R-215Ld-25G(200)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
Siniat Twin Frame Partition Twin(AB)-CS90W-215dB-100G(300)

Siniat Twin Frame Partition Twin(AB)-CS90W-215dB-100G(300)

Verified 3 months ago

Siniat

Twin frame metal stud partition for use where the highest fire and acoustic performance is required.
Sponsored
GypLyner Xternal - T106026 (EN)

GypLyner Xternal - T106026 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an Inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus insulation to external side and two layers of Gyproc SoundBloc 15mm to the internal side of 70mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106022 (EN)

GypLyner Xternal - T106022 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side and three layers of Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106027 (EN)

GypLyner Xternal - T106027 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side and three layers of Gyproc FireLine 15mm to the internal side of 70mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106023 (EN)

GypLyner Xternal - T106023 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus insulation to external side and three layers of Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106030 (EN)

GypLyner Xternal - T106030 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side and three layers of Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 100mm Isover Steel Frame Infill Batt in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106031 (EN)

GypLyner Xternal - T106031 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus insulation to external side an inner layer of Gyproc Habito 12.5mm and outer layer Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106017 (EN)

GypLyner Xternal - T106017 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction, including a 20mm deflection head, with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus insulation to external side and one layer of Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106018 (EN)

GypLyner Xternal - T106018 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus insulation to external side and one layer of Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106028 (EN)

GypLyner Xternal - T106028 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 50mm Isover Polterm Max Plus insulation to external side an inner layer of Gyproc Habito 12.5mm and outer layer Gyproc FireLine 15mm to the internal side of 70mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106029 (EN)

GypLyner Xternal - T106029 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with one layer of Glasroc X Sheathing Board 12.5mm to external side an inner layer of Gyproc Habito 12.5mm and two outer layers Gyproc SoundBloc 15mm to the internal side of 70mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.
Sponsored
GypLyner Xternal - T106036 (EN)

GypLyner Xternal - T106036 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 200mm Isover Polterm Max Plus insulation to external side an inner layer of Gyproc Habito 12.5mm and two outer layers Gyproc SoundBloc 15mm to the internal side of 100mm SFS framework. 100mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 3000mm.
Sponsored
GypLyner Xternal - T106032 (EN)

GypLyner Xternal - T106032 (EN)

Verified 2 months ago

British Gypsum

A non-loadbearing external wall construction including a 20mm deflection head with an inner layer of Glasroc X Sheathing Board 12.5mm and outer layer of 100mm Isover Polterm Max Plus insulation to external side an inner layer of Gyproc Habito 12.5mm and outer layer Gyproc FireLine 15mm to the internal side of 100mm SFS framework. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4000mm.

Showing 3457-3492 of 3556