NBS Source
I'm a manufacturer

"screen based systems"

16,668 results found

Can't find what you're looking for?

Sort by:

Showing 9793-9828 of 10000

Sponsored
GypLyner Independent - B216005 (B) (EN)

GypLyner Independent - B216005 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3000mm.
Sponsored
GypLyner Independent - B216026 (D) (EN)

GypLyner Independent - B216026 (D) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3900mm.
Sponsored
GypLyner Independent - B216006 (F) (EN)

GypLyner Independent - B216006 (F) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216006 (E) (EN)

GypLyner Independent - B216006 (E) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216028 (B) (EN)

GypLyner Independent - B216028 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3300mm.
Sponsored
GypLyner Independent - B216026 (C) (EN)

GypLyner Independent - B216026 (C) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3300mm.
Sponsored
GypWall Shaft - G306032 (B) (EN)

GypWall Shaft - G306032 (B) (EN)

Verified 2 months ago

British Gypsum

Gypframe 146 TI 90 Tabbed ‘I’ Studs at 600mm centres with Glasroc F FireCase 20mm between studs, secured by Gypframe G102 Retaining Channel. Three layers of Glasroc F FireCase 15mm to non-shaft side. For heights up to 6000mm.
Sponsored
GypWall Single Frame - A206A015 (B) (EN)

GypWall Single Frame - A206A015 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc WallBoard 12.5mm each side of Gypframe 70 AS 50 AcouStuds at 600mm centres. For heights up to 4700mm.
Sponsored
GypWall Staggered - A233007 (B) (EN)

GypWall Staggered - A233007 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm each side of Gypframe 92 I 90 ‘I’ Studs in Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel. Gypframe SC2 Spacer Clips and alternate studs staggered in the channel at 300mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 5700mm.
Sponsored
GypWall Single Frame - H206015 (B) (EN)

GypWall Single Frame - H206015 (B) (EN)

Verified 2 months ago

British Gypsum

Inner layer of Gyproc WallBoard 12.5mm with an outer layer of Glasroc H TileBacker 12.5mm each side of Gypframe 70 S 50 'C' Studs at 600mm centres. For heights up to 4600mm.
Sponsored
GypWall Staggered - A233006S (B) (EN)

GypWall Staggered - A233006S (B) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc SoundBloc 15mm each side of Gypframe 92 I 90 ‘I’ Studs in Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel. Gypframe SC2 Spacer Clips and alternate studs staggered in the channel at 300mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity with 2mm Thistle MultiFinish on each side. For heights up to 5400mm.
Sponsored
GypLyner Independent - B216006 (C) (EN)

GypLyner Independent - B216006 (C) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3900mm.
Sponsored
GypLyner Independent - B216028 (C) (EN)

GypLyner Independent - B216028 (C) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3900mm.
Sponsored
GypLyner Independent - B216025 (F) (EN)

GypLyner Independent - B216025 (F) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216006 (D) (EN)

GypLyner Independent - B216006 (D) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216025 (E) (EN)

GypLyner Independent - B216025 (E) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216028 (D) (EN)

GypLyner Independent - B216028 (D) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 15mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Single - TL-Universal (C) (EN)

GypLyner Single - TL-Universal (C) (EN)

Verified 2 months ago

British Gypsum

Solid masonry background with Gypframe GL1 Lining Channel framework fixed to one side with a cavity between 25mm to 125mm clad with one layer of Gyproc ThermaLine PIR 63mm
Sponsored
GypLyner Single - TL-Universal (D) (EN)

GypLyner Single - TL-Universal (D) (EN)

Verified 2 months ago

British Gypsum

Solid masonry background with Gypframe GL1 Lining Channel framework fixed to one side with a cavity between 25mm to 125mm clad with one layer of Gyproc ThermaLine PIR 78mm
Sponsored
GypLyner Single - TL-Universal (E) (EN)

GypLyner Single - TL-Universal (E) (EN)

Verified 2 months ago

British Gypsum

Solid masonry background with Gypframe GL1 Lining Channel framework fixed to one side with a cavity between 25mm to 125mm clad with one layer of Gyproc ThermaLine PIR 93mm
Sponsored
GypLyner Independent - B216027 (C) (EN)

GypLyner Independent - B216027 (C) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
Sponsored
GypWall Shaft - G306009 (B) (EN)

GypWall Shaft - G306009 (B) (EN)

Verified 2 months ago

British Gypsum

Gypframe 146 TI 90 Tabbed ‘I’ Studs at 600mm centres with Glasroc F FireCase 20mm between studs, secured by Gypframe G102 Retaining Channel. Two layers of Glasroc F FireCase 15mm to non-shaft side. For heights up to 6000mm.
Sponsored
GypLyner Independent - B216027 (D) (EN)

GypLyner Independent - B216027 (D) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypWall Resilient - A316018 (B) (EN)

GypWall Resilient - A316018 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm each side of Gypframe 146 S 50 'C' Studs at 600mm centres with Gypframe RB1 Resilient Bar at 600mm centres to both sides. 50mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 5700mm.
Sponsored
GypLyner Independent - B216005 (D) (EN)

GypLyner Independent - B216005 (D) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm to one side of Gypframe 70 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Single - TL-Universal (B) (EN)

GypLyner Single - TL-Universal (B) (EN)

Verified 2 months ago

British Gypsum

Solid masonry background with Gypframe GL1 Lining Channel framework fixed to one side with a cavity between 25mm to 125mm clad with one layer of Gyproc ThermaLine PIR 53mm
Sponsored
GypLyner Independent - B216006 (B) (EN)

GypLyner Independent - B216006 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 15mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3300mm.
Sponsored
GypWall Shaft - G306030 (B) (EN)

GypWall Shaft - G306030 (B) (EN)

Verified 2 months ago

British Gypsum

Gypframe 60 I 70 ‘I’ Studs at 600mm centres with Glasroc F FireCase 20mm between studs, secured by Gypframe G102 Retaining Channel. Three layers of Glasroc F FireCase 15mm to non-shaft side. For heights up to 4500mm.
Sponsored
GypLyner Independent - B216026 (F) (EN)

GypLyner Independent - B216026 (F) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypWall Shaft - G306036 (B) (EN)

GypWall Shaft - G306036 (B) (EN)

Verified 2 months ago

British Gypsum

Gypframe 92 I 90 ‘I’ Studs at 600mm centres with Glasroc F FireCase 20mm between studs, secured by Gypframe G105 Retaining Channel. Three layers of Glasroc F FireCase 15mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 5000mm.
Sponsored
GypLyner Independent - B216005 (C) (EN)

GypLyner Independent - B216005 (C) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc SoundBloc 12.5mm to one side of Gypframe 60 I 70 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 3600mm.
Sponsored
GypLyner Independent - B216025 (B) (EN)

GypLyner Independent - B216025 (B) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 12.5mm to one side of Gypframe 60 I 50 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.
Sponsored
GypWall Single Frame - A206028 (B) (EN)

GypWall Single Frame - A206028 (B) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc WallBoard 15mm each side of Gypframe 146 S 50 'C' Studs at 600mm centres. For heights up to 5000mm.
Sponsored
GypLyner Independent - B216026 (E) (EN)

GypLyner Independent - B216026 (E) (EN)

Verified 2 months ago

British Gypsum

One layer of Gyproc FireLine 15mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216027 (E) (EN)

GypLyner Independent - B216027 (E) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 12.5mm to one side of Gypframe 92 I 90 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.
Sponsored
GypLyner Independent - B216027 (F) (EN)

GypLyner Independent - B216027 (F) (EN)

Verified 2 months ago

British Gypsum

Two layers of Gyproc FireLine 12.5mm to one side of Gypframe 146 I 80 ‘I’ Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 4000mm.

Showing 9793-9828 of 10000

Feedback