NBS Source
List your products
ZA Linear Actuator
Description

A range of linear actuators, suitable for façade and roof windows.

Features and benefits:

  • Can be used for windows and vents for smoke exhaust; D+H Euro SHEV in accordance with EN 12101-2 and for daily ventilation.
  • With motor electronics controlled via microprocessor or integrated BSY+ motor and synchronized electronics controlled via microprocessor (BSY+ Set drive only).
  • Option of up to eight drives in one synchronous group (BSY+ Set drive only).
  • Low current consumption thanks to high efficiency.
  • Option of cable infeed above and below.
  • Drive unit can be changed from left to right.
  • Programmable drive functions and different drive parameters.
  • Running speed in closed direction decreases to 5 mm/s (passive closing edge protection).
  • Time-controlled reversing when an obstacle is detected in the closed direction (active closing edge protection).

General information

Uniclass 2015

Pr_75_50_02_46 Linear actuatorsPrimary

CAWS

L10/10 Wood windows

L10/15 Wood windows

L10/20 Steel windows

L10/210 Wood windows

L10/25 Aluminium windows

L10/250 Wood windows

L10/260 Wood windows

L10/30 PVC-U windows

L10/31 PVC-U windows

L10/310 Steel windows

L10/315 Steel windows

L10/33 Proprietary windows

L10/330 Aluminium windows

L10/335 Aluminium windows

L10/350 PVC-U windows

L10/360 PVC-U windows

L10/380 PVC-U windows

L10/390 Proprietary windows

L10/400 Composite windows

L10/410 Composite windows

L10/45 Rooflights

L10/460 Rooflights

L10/480 Roof windows

L10/490 Roof ventilators

L10/50 Roof windows

L10/650 Metal louvres

Specification data - Linear actuators

Product Reference

ZA Linear Actuator

Type

See 'Options' below and insert reference.

Accessories

None

Brackets

Various options available consult literature and insert product reference(s).

Cables

Standard product features

Technical characteristics:

  • Supply: 24 V d.c (1 A). Except for '- K' drives which requires 230 V (50 Hz).
  • Duty cycle: 30 %.
  • Force of pressure: 300, 800, 1000, 1500 N.
  • Tensile force: 300, 800, 1000 N.
  • Nominal locking force: 1100 N.
  • Service life: > 10 000 double strokes.
  • Open running speed: 7.1 mm/s. (Except ZA 105-K drive: 10 mm/s).
  • Open running speed: SHEV: 8 mm/s, HS: 17 mm/s.
  • Closed running speed: 7.1 mm/s. (Except ZA 105-K drive: 10 mm/s).
  • Ingress protection rating: IP 65.
  • Fire resistance: B300 (30 min/ 300 °C).
  • Rack and pinion: V2A.
  • Housing: Aluminium/ Polycarbonate.
  • Colour: Silver (~ RAL 9006).
  • Connection: 2.5 m cable.
  • Standards: EN 12101-2 CE certified, VdS G 500001, TUV SUD B 08 11 22802 026.

Product Options

Type:

- ZA 35 drive (tensile force: 300 N):

  • ZA 35/350 (Stroke: 350 mm).
  • ZA 35/500 (Stroke: 500 mm).
  • ZA 35/600 (Stroke: 600 mm).
  • ZA 35/600 (Stroke: 800 mm).
  • ZA 35/800 (Stroke: 1000 mm).
  • ZA 35/600 (Stroke: 1100 mm).
  • ZA 35/600 (Stroke: 1200 mm).
  • ZA-PLP. Variable equipment possible.

- ZA 35-K-BSY+ drive (tensile force: 300 N, direct control via 230 V):

  • ZA 35/350-K-BSY+ (Stroke: 350 mm).
  • ZA 35/350-K-BSY+ (Stroke: 500 mm).
  • ZA 35/350-K-BSY+ (Stroke: 600 mm).
  • ZA 35/350-K-BSY+ (Stroke: 800 mm).
  • ZA 35/350-K-BSY+ (Stroke: 1000 mm).
  • ZA 35/350-K-BSY+ (Stroke: 1100 mm).
  • ZA 35/350-K-BSY+ (Stroke: 1200 mm).
  • ZA-K-BSY+. Variable equipment possible.

- ZA 85 drive (tensile force: 800 N):

  • ZA 85/350 (Stroke: 350 mm).
  • ZA 85/500 (Stroke: 500 mm).
  • ZA 85/600 (Stroke: 600 mm).
  • ZA 85/800 (Stroke: 800 mm).
  • ZA 85/1000 (Stroke: 1000 mm).
  • ZA 85/1000 (Stroke: 1100 mm).
  • ZA 85/1000 (Stroke: 1200 mm).
  • ZA-PLP. Variable equipment possible.

- ZA 85-HS drive (tensile force: 800 N, open running speed-HS: 17 mm/s):

  • ZA 85/600-HS (Stroke: 350 mm).
  • ZA 85/600-HS (Stroke: 500 mm).
  • ZA 85/600-HS (Stroke: 600 mm).
  • ZA 85/800-HS (Stroke: 800 mm).
  • ZA 85/1000-HS (Stroke: 1000 mm).
  • ZA 85/1000-HS (Stroke: 1100 mm).
  • ZA 85/1000-HS (Stroke: 1200 mm).
  • ZA-PLP. Variable equipment possible.

- ZA 85-BSY+ Set drive (tensile force: 800 N):

  • ZA 85/500-BSY+ Set (Stroke: 350 mm).
  • ZA 85/500-BSY+ Set (Stroke: 500 mm).
  • ZA 85/600-BSY+ Set (Stroke: 600 mm).
  • ZA 85/800-BSY+ Set (Stroke: 800 mm).
  • ZA 85/1000-BSY+ Set (Stroke: 1000 mm).
  • ZA 85/1000-BSY+ Set (Stroke: 1100 mm).
  • ZA 85/1000-BSY+ Set (Stroke: 1200 mm).
  • ZA-BSY+. Variable equipment possible.

- ZA 85-BSY+ HS Set drive (tensile force: 800 N, open running speed-HS: 17 mm/s):

  • ZA 85/600-BSY+ HS Set (Stroke: 350 mm).
  • ZA 85/600-BSY+ HS Set (Stroke: 500 mm).
  • ZA 85/600-BSY+ HS Set (Stroke: 600 mm).
  • ZA 85/800-BSY+ HS Set (Stroke: 800 mm).
  • ZA 85/1000-BSY+ HS Set (Stroke: 1000 mm).
  • ZA 85/1000-BSY+ HS Set (Stroke: 1100 mm).
  • ZA 85/1000-BSY+ HS Set (Stroke: 1200 mm).
  • ZA-BSY+. Variable equipment possible.

- ZA 105 drive (tensile force: 1000 N):

  • ZA 105/500 (Stroke: 350 mm).
  • ZA 105/500 (Stroke: 500 mm).
  • ZA 105/600 (Stroke: 600 mm).
  • ZA 105/800 (Stroke: 800 mm).
  • ZA 105/1000 (Stroke: 1000 mm).
  • ZA 105/1000 (Stroke: 1100 mm).
  • ZA 105/1000 (Stroke: 1200 mm).
  • ZA-PLP. Variable equipment possible.

- ZA 105-HS drive (tensile force: 1000 N, open running speed-HS: 17 mm/s):

  • ZA 105/600-HS (Stroke: 350 mm).
  • ZA 105/600-HS (Stroke: 500 mm).
  • ZA 105/600-HS (Stroke: 600 mm).
  • ZA 105/800-HS (Stroke: 800 mm).
  • ZA 105/800-HS (Stroke: 1000 mm).
  • ZA 105/800-HS (Stroke: 1100 mm).
  • ZA 105/800-HS (Stroke: 1200 mm).
  • ZA-PLP. Variable equipment possible.

- ZA 105-BSY+ HS Set drive (tensile force: 1000 N, open running speed-HS: 17 mm/s):

  • ZA 105/600-BSY+ HS Set (Stroke: 350 mm).
  • ZA 105/600-BSY+ HS Set (Stroke: 500 mm).
  • ZA 105/600-BSY+ HS Set (Stroke: 600 mm).
  • ZA 105/800-BSY+ HS Set (Stroke: 800 mm).
  • ZA 105/1000-BSY+ HS Set (Stroke: 1000 mm).
  • ZA 105/1000-BSY+ HS Set (Stroke: 1100 mm).
  • ZA 105/1000-BSY+ HS Set (Stroke: 1200 mm).
  • ZA-BSY+. Variable equipment possible.

- ZA 105-K drive (tensile force: 1000 N, direct control via 230 V):

  • ZA 105/350-K (Stroke: 350 mm).
  • ZA 105/500-K (Stroke: 500 mm).
  • ZA 105/800-K (Stroke: 800 mm).
  • ZA 105/1000-K (Stroke: 1000 mm).
  • ZA 105/1000-K (Stroke: 1100 mm).
  • ZA 105/1000-K (Stroke: 1200 mm).
  • ZA-K. Variable equipment possible.

- ZA 105-K-BSY+ drive (tensile force: 1000 N, direct control via 230 V):

  • ZA 105/350-K-BSY+ (Stroke: 350 mm).
  • ZA 105/500-K-BSY+ (Stroke: 500 mm).
  • ZA 105/600-K-BSY+ (Stroke: 600 mm).
  • ZA 105/800-K-BSY+ (Stroke: 800 mm).
  • ZA 105/1000-K-BSY+ (Stroke: 1000 mm).
  • ZA 105/1000-K-BSY+ (Stroke: 1100 mm).
  • ZA 105/1000-K-BSY+ (Stroke: 1200 mm).
  • ZA-K-BSY+. Variable equipment possible.

- ZA 155 drive (tensile force: 1500 N):

  • ZA 155/500 (Stroke: 350 mm).
  • ZA 155/500 (Stroke: 500 mm).
  • ZA 155/500 (Stroke: 600 mm).
  • ZA 155/500 (Stroke: 800 mm).
  • ZA 155/500 (Stroke: 1000 mm).
  • ZA 155/500 (Stroke: 1100 mm).
  • ZA 155/500 (Stroke: 1200 mm).
  • ZA-PLP. Variable equipment possible.

Similar products from Dyer Environmental Controls Ltd