Warm, non-vented standing seam roofing.
The system can be used for roofs with a pitch from 3 to 70º and for buildings with humidity classes of between 1 to 4 (dwellings with high occupancy, sport halls, etc).
Non-vented warm roof system for buildings with humidity classes between 1 and 4 using VMZINC Plus and an engineered panel as a substrate.
The supporting structure can be a steel or plywood deck. Either deck is covered by Aludex Max (an aluminium foil-reinforced bituminous vapour barrier with a high water vapour resistance of 7000 MNsg) installed with cold or hot glued joints. All insulation materials must have a compression strength of minimum 50 kPa (0.5 kg/cm² ), at a maximum 10% deformation and must be dimensionally stable at up to 100°C and comply with current Building
Regulations.
Between the VMZINC PLUS and the insulation, a VMZINC Membrane is fixed with an overlap that varies depending on the slope. The insulation material must also comply with the fire resistance requirements of the Building Regulations.
Features and benefits:
System build-up:
VMZINC PLUS:
A product which allows zinc to be installed on ventilated plywood as well as specific warm (non-ventilated) substrates. The product consists of VMZINC (in all finishes) having a 60 μm coating applied to the underside thus allowing a more varied amount of substrates to be used and eliminating the risk of the formation of white rust on the underside of the zinc standing seam panels. VMZINC PLUS resists to an abrasion of 140 L when tested in accordance with ASTM D 968.
Life Cycle Analysis (LCA):
VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.
Color | Blue Green Grey Red Brown |
Finish | Natural Pre-treated |
Material | Zinc |
Shape | Rectangle |
Length | 13000 mm Guidance for specification option: Max. |
Width | 430 mm 530 mm 600 mm |
Height | 25 mm |
Warranty description | 50 year Guidance for specification option: Up to 50 year material warranty available on a project basis. |
Uniclass | |
CAWS | H74/5 Zinc sheet fully supported covering to dormers H74/150 Zinc sheet fully supported covering to dormers H74/110 Zinc sheet fully supported roof covering |
Product range |
System performance | Structural performance – wind actionsDesign of zinc sheet fully supported roof covering systemsDurabilityAesthetic performanceFire performance |
Membrane | VMZINC Membrane. |
Insulation | Mineral board.Polyisocyanurate (PIR). |
Air and vapour control layer | Aludex Max air and vapour barrier - fully supported. |
Substrate | Galvanized steel deck 0.7 mm.18 mm plywood. |
Sheet underlay | |
Material | VMZINC membrane. |
Fasteners | Stainless steel clips/bearing plates, polypropylene pegs and stainless steel screws. |
Timber cores for batten roll joints | |
Fasteners to substrate | Stainless steel clips/bearing plates, polypropylene pegs and stainless steel screws. |
Zinc | Zinc-titanium-copper. |
Longitudinal joints | |
Form | Standing seam joints. |
Fixing standing seam joints | VMZINC clips, 1.4301 (304) stainless steel. The thickness of the fixing clip is 0.5 mm. The sliding clips have a moving component, which is 0.4 mm thick, and a 70 mm long slot. |
Fasteners to substrate | It is recommended that screws be used to secure the clips with three being used per sliding clip. The use of nails offers significantly less resistance, but in the event of using nails, contractors are advised to use ring shank nails. |
Cross joints | |
Form | Double lock welts.Roof steps. |
Eave details | |
Form | Dog tooth.Swept eave on T plate with water check. |
Fixings | Fixed with cleats using a 6 mm rebate on the substrate. |
Verge details | |
Form | Standing seam verge. |
Fixing | |
Top edge | VMZINC stainless steel sliding clip. |
Bottom edge | The eave should be fixed to a T plate with water check which must be secured using cleats. |
Ridge and hip details | |
Form | G3 ridge.Traditional with upstand. |
Fixings | Ridge clip G3. |
Samples required | Product samples |
Execution | Layout and zinc work generally. |
System completion | Submittals (e.g. operation and maintenance manuals). |
Product Reference | VMZINC Standing Seam Roofing - Structural Roof (Warm, Non-vented) |
Finish: | Pre-weathered. Natural. Guidance for specification option: Only available with Natural colour option. Manufacturer guidanceAvailable in a choice of either natural finish or eight pre-weathered finishes as well as bespoke PIGMENTO colours. |
Standard | EN 15804, ASTM D 968, ISO 14001 and ISO 9001. |
Coil | 0.7 x 500 mm. 0.7 x 600 mm. 0.7 x 670 mm. Guidance for specification option: Not AZENGAR. 0.8 x 500 mm. 0.8 x 600 mm. Manufacturer guidanceCoil thickness x coil width. Non-standard widths between 60–600 mm can also be produced. |
Centres | 430 mm. 530 mm. 600 mm. Guidance for specification option: Not AZENGAR. Manufacturer guidanceStanding seam centres. |
Panel weight | 6 kg/m² (approximately). |
Fire performance: | Fire classification A1 (Natural Zinc, QUARTZ ZINC, ANTHRA-ZINC and AZENGAR) and A2-s1,d0 (PIGMENTO and VMZINC PLUS) according to EN 13501-1:2002. BROOF(t4) according to EN 13501-5. |
Colour | Natural VMZINC®. Guidance for specification option: Only available with Natural finish option. Natural VMZINC has a shiny metallic appearance when new and develops a patina over time. In facade applications, it may take 10 years for the matt grey patina to form. It can be quickly soldered without removing the patina. Standard PIGMENTO® BLUE. Standard PIGMENTO® GREEN. Standard PIGMENTO® BROWN. Standard PIGMENTO® RED. |
Contains Red List materials | No |
Country of material origin | France |
Country of product manufacture | France |
Material | Zinc |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceSee EN15804 EPD. |
Recyclability | 100% Guidance for specification option: Fully recyclable. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % Guidance for specification option: 20% (approximately). |
Expected Life | 100 year |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
IFC2X3 | 1 | |
Revit 2016 | 2 |
VMZINC Roofing + Rainwater Design Specification & Installation Guidelines Dec 20
VMZINC EN15804 Natural Rolled Zinc
ISO 9001
ISO 14001
EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS
BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA
BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT
VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.
VMZINC Standing Seam Installation Guide - Information about the Use and Detailing of VMZINC March 2018
BBA Certificate for the Structural roof
VMZINC Standing Seam Roofing - Compact Roof (Warm, Non-vented)
VMZINC Standing Seam Roofing - Standing Seam Roof On Metal Faced Panels (Warm, Non-vented)
VMZINC Standing Seam Roofing - Standing Seam Roof On Open Gap Boarding (Cold, Vented)
VMZINC Standing Seam Roofing - Standing Seam Roof On Plywood (Cold, Vented)
VMZINC Standing Seam Roofing - Standing Seam Roof On Plywood Bonded To Phenolic Foam (Warm, Non-vented)