NBS Source
I'm a manufacturer

Vlo Ultra-12 - Underfloor Heating

Verified by manufacturer 4 months ago

Warmup plc

Low build hydronic underfloor heating system.

Jump to:
+44 345 345 2288 Website

Application

Particularly suitable for retrofits and off-plan sales into new builds where floor height is at a premium.

Description

The VLo Ultra-12 is a lightweight and robust underfloor heating system. The range comprises of five panels, maximising usability for the installer, with each panel purposely designed to hold the pipe securely across the entire floor.


Designed for use with Warmup’s 12 mm PE-RT pipe that inserts directly into the board channels for quick and easy installation, the system has been created with speed and efficiency in mind.


The straight panel with omega profiled 150 µm aluminium diffuser channels ensures maximum surface contact between the aluminium diffuser and PE-RT pipe; optimising heat output, reducing heat up times whilst also minimising heat loss through increased insulation.


The aluminium surface of the heating panels is covered with a securely bonded, fibreglass reinforced fleece, providing an ideal surface for tiling, removing the need for specialist primers.


Features and benefits:

  • Low profile floor finish.
  • High system performance.
  • Robust and efficient panels.
  • Quick and easy installation.
  • Lightweight.
  • Maximum user usability with five panels.
  • Optimises heat output and minimises heat loss.
  • Low running costs.
  • Used with traditional boilers and heat pumps.


System components:

  • PE-RT Pipe - Warmup PE-RT (Polyethylene of Raised Temperature Resistance) pipe. The pipe guarantees leak free performance with a smooth internal structure for improved flow, reduced pressure loss and deposit formation. 
  • Warmup Primer (ACC-PRIMER) - A ready to use, bond enhancing and solvent-free single component primer for the preparation of absorbent and non-absorbent floors and walls with or without surface heating.
  • Pipe bend supports (WHS-P-BEND12) - Used for supporting pipes to make a smooth 90-degree turn where needed and provides a rigid bend which changes the pipes direction without causing excessive bending.
  • Pipe clips (UK-WUK-HY-ACC-PIPECLIPS12) - The robust pipe clips feature a press in to secure and press in to release design making mounting of the pipe easy. They link together to form a single rail and secure pipes at 25 mm centres, neatly aligning them to the manifold ports.

General information

Color

Other

Material

Polyethylene

Aluminium

Polystyrene

Guidance for specification option:

XPS.

Length

1200 mm

Width

600 mm

Height

18 mm

Warranty description

Lifetime

Guidance for specification option:

Consult manufacturer for details.

Uniclass

Ss_60_40_92_94 Underfloor low-temperature hot water heating systemsPrimary

CAWS

T90/475 Underfloor heating systems

T90/475 Underfloor heating systems

Specification data - Underfloor low-temperature hot water heating systems

Heat source

Traditional boiler.

Heat pump.

Pumps

-

Manufacturer guidance

Consult manufacturer and insert requirements or omit.

Pipes

-

Distribution

PE-RT (Polyethylene of Raised Temperature Resistance) pipe.

Underfloor

Multilayer pipes for water.

Pipeline accessories

Pipe bend supports.

Pipeline supports

Pipe clips.

Controls

-

Controllers

Warmup 6iE - Onyx black housing, dark chrome band (6iE-01-OB-DC).

Warmup 6iE - Bright porcelain housing, light chrome band (6iE-01-BP-LC).

Warmup Element - Light housing, rose gold band (ELM-01-WH-RG).

Warmup Element - Dark housing, dark chrome band (ELM-01-OB-DC).

Sensors

Floor sensor.

Guidance for specification option:

Must be recessed into the Ultra-12 panel and taped in position.

Floor components

Ultra-12 - Straight Panel (U12-SP-PANEL).

Guidance for specification option:

  • Extruded polystyrene with 150 μm thick aluminium foil layer on top, with a fibreglass reinforcement mesh and a 100% recycled polyester fleece on top and bottom.
  • Pipe centres: 150 mm.
  • Panel weight: 1 kg.

Ultra-12 - Curve Panel (U12-CP-PANEL).

Guidance for specification option:

  • Extruded polystyrene with a fibreglass reinforcement mesh and a 100% recycled polyester fleece on bottom.
  • Panel weight: 0.5 kg.

Ultra-12 - Straight Service Panel (U12-SS-PANEL).

Guidance for specification option:

  • Extruded polystyrene with a fibreglass reinforcement mesh and a 100% recycled polyester fleece on bottom.
  • Panel weight: 0.5 kg.

Ultra-12 - Curve Service Panel (U12-CS-PANEL).

Guidance for specification option:

  • Extruded polystyrene with a fibreglass reinforcement mesh and a 100% recycled polyester fleece on bottom.
  • Panel weight: 0.5 kg.

Ultra-12 - Plain Panel (U12-PP-PANEL).

Guidance for specification option:

  • Extruded polystyrene with a fibreglass reinforcement mesh and a 100% recycled polyester fleece on top and bottom.
  • Panel weight: 0.7 kg.

Primer

Warmup Primer - ACC-PRIMER.

Panel dimensions

600 x 1200 x 18 mm.

Density

50 kg/m³.

Manufacturer guidance

Ultra-12 panels - Foam component.

ThermalConductivity

0.034 W/mK.

Manufacturer guidance

Ultra-12 panels - Foam component.

CompressiveStrength

500 kN/m².

Manufacturer guidance

10% deflection.

Ultra-12 panels - Foam component.

Water absorption

<1.0% by volume

Manufacturer guidance

2-day immersion.

Ultra-12 panels - Foam component.

Water absorption by capillarity

Zero.

Manufacturer guidance

Ultra-12 panels - Foam component.

Coefficient of linear expansion

0.07 mm/mK.

Manufacturer guidance

Ultra-12 panels - Foam component.

Water vapour diffusion resistance

110–225 µ.

Manufacturer guidance

Ultra-12 panels - Foam component.

FireRating

Euroclass E.

Manufacturer guidance

Ultra-12 panels - Foam component.

Ozone depleting potential (ODP)

Zero.

Manufacturer guidance

Ultra-12 panels - Foam component.

Global warming potential (GWP)

<0.29.

Manufacturer guidance

Ultra-12 panels - Foam component.

Sustainability data

Contains Red List materials

No

Country of material origin

Egypt

Country of product manufacture

Egypt

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

N/A - Measured internally under greenhouse protocol guidance.

Recyclability

Recyclable

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

Contains 100% recycled polyester fleece on top and bottom

Literature

VLo Ultra-12 Low Build System Technical Specification

VLo Ultra-12 Low Build System Technical Specification

Similar products from Warmup plc

Clypso System - Underfloor Heating

Clypso System - Underfloor Heating

VLo Econna-12  - Underfloor Heating

VLo Econna-12 - Underfloor Heating

Vlo Nexxa-12 - Underfloor Heating

Vlo Nexxa-12 - Underfloor Heating