Through fixed metal rainscreen cladding.
For horizontal, vertical and soffit applications. Suitable for new build or refurbishment projects.
VariAL-TF offers a functional and robust solution for flat panel rainscreen cladding applications, which is simple and cost effective to design, detail and install. Fixed by a colour matched rivet through the face of the panel to allow minimal disruption of aesthetics, designers can achieve the effect of a smooth facade by specifying minimal shadow gaps when compared with cassette systems.
Features and benefits:
Color | Bronze Blue Beige Black Brown |
Finish | Anodized Powder-coated Coated Anti-graffiti Anti-microbial |
Material | Aluminium Cor-Ten Composite |
Shape | Rectangle Square Rhombus Triangle Pentagon |
Width | 1470 mm 3970 mm 5970 mm 1970 mm |
Height | 1470 mm 3970 mm 5970 mm 1970 mm |
WarrantyDescription | 25 year |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
System performanceFor fire testing: • Mineral wool insulation (<340mm thickness) with classification A1 to BS EN 13501-1 was applied on this system. • The cavity for the system was 25–100 mm. | Fire performance: Reaction to fire to EN 13501-1, Euroclass A1.Aluminium, stainless steel or corten with no coating or anodized coating. Fire performance: Reaction to fire to EN 13501-1, Euroclass A2-s1, d0.2–3 mm Aluminium with PPC coating or with 4 mm Alucobond A2 ACM. |
Thermal insulationInsulation, if used, should be mineral wool of classification A1, thickness 50–340 mm. Refer to the Warringtonfire classification report for further details. | - |
Breather membrane | - |
MaterialThe system does not include a breather membrane or vapour barrier since these components are not Class A1. If a vapour barrier is required, refer to the guidance in Approved Document B regarding the required fire classification. | - |
Secondary support structureThe brackets can be also installed on A&L standard top hats which can extend the cladding zone 50 mm further. | AX1 AxiAL carrier system.Aluminium support system. From 45 mm to 395 mm. AX2 AxiAL carrier system.Aluminium support system. From 45 mm to 425 mm. AX3 AxiAL carrier system.Aluminium support system. From 53 mm to 225 mm. AX4 AxiAL carrier system.Aluminium support system. From 25 mm to 40 mm – for shallow cavity zone. System with no adjustment range in the cladding zone AX1R AxiAL carrier system.Stainless steel support system. From 52 mm to 335 mm. AX2R AxiAL carrier system.Stainless steel support system. From 52 mm to 333 mm. AX3R AxiAL carrier system.Stainless steel support system. From 50 to 225 mm. AX4R AxiAL carrier system.Stainless steel support system. From 25 mm to 40 mm. System with no adjustment range in the cladding zone. |
Cavity fire barriers | - |
HorizontalFire cavity barriers are not included within the system and should be specified and designed by a qualified engineer. | - |
VerticalFire cavity barriers are not included within the system and should be specified and designed by a qualified engineer. | - |
Cladding panels | - |
Material | 4 mm A1/A2 ACM.Maximum panel size: 5970 x 1470 mm (H x W). 2 mm Solid Aluminium.Maximum panel size: 5970 x 1970 mm (H x W). 3 mm Solid Aluminium.Maximum panel size: 5970 x 1970 mm (H x W). 2 mm Perforated Aluminium.Maximum panel size: 5970 x 1970 mm (H x W). 3 mm Perforated Aluminium.Maximum panel size: 5970 x 1970 mm (H x W). 2 mm Cor-Ten Steel.Maximum panel size: 3970 x 1970 mm (H x W). 3 mm Cor-Ten Steel.Maximum panel size: 3970 x 1970 mm (H x W). |
Panel jointsJoint details are available in varying widths to suit requirements and can be matching or contrasting colours. Minimum joint size will be dependent on panel length allowing for expansion/ contraction. Joint width: 20 mm (standard), 25 mm (maximum), 10 mm (minimum). Consult manufacturer and insert requirements. | Vertical closed joint, horizontal open joint.A minimum of 50 mm ventilated air cavity is recommended by the manufacturer for an open joint system to prevent water crossing the air gap to the insulation. Passage of water through these joints is reduced by pressure-equalising the cavity behind the joint.
Closed joints.For closed joint construction, the facade system has to be drained and ventilated and the minimum air gap required is 25 mm.
|
Colour/ FinishConsult manufacturer and insert requirements. | - |
Panel fixingsRivets can be matched with panel finishing so they are hardly noticeable from a distance or they can be in contrast colour to be part of the facade design pattern. | Large flange rivet – corrosion resistant, PPC finish. For aluminium and ACM cladding. Inset RAL or colour code. Large flange rivet – corrosion resistant, PPC with anodic effect. For aluminium and ACM cladding. Inset RAL or colour code. Full stainless steel rivet, PPC finish. For corten steel cladding. Full stainless steel rivet, PPC with anodic effect. |
Contains Red List materials | No |
Country of product manufacture | United Kingdom |