NBS Source
I'm a manufacturer

VariAL-CF3 Aluminium Cladding System

Verified by manufacturer 4 months ago

Ash & Lacy

Metal rainscreen cladding.

Jump to:
BOS
+44 (0)121 525 1444 Website

Application

For horizontal and vertical applications.

Description

VariAL-CF3 offers a cost-effective rainscreen cassette solution where secret-fixed panels are not a project design requirement. Comprising a fully adjustable support system, relying on a colour coated discrete mechanical fixing in the horizontal shadow joint. VariAL-CF3 is designed specifically for solid aluminium facades, which can be finished using a range of coating technologies.


Features and benefits:

  • Horizontal or vertical orientated and square wall cassette panels.
  • Softened panel bend radius.
  • Cost-effective concealed fix.
  • Flexibility in joint dimensions and panel depths.
  • CWCT Tested
  • Fire tested to EN13501-1 - A1 and A2,s1-d0 options
  • BBA Certification (in progress)

General information

Color

Black

Blue

Bronze

Brown

Copper

Show more

Manufacturer guidance

All RAL, NCS, Metallics, Patina and Stone Effect, Anodised Effect

Finish

Anodized

Powder-coated

PVdF

Gloss

Matt

Show more

Material

Aluminium

Shape

Rectangle

Square

Width

1340 mm

5840 mm

Height

1340 mm

5840 mm

Warranty description

25 year

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Fire performance: Reaction to fire to EN 13501-1, Euroclass A1.

Guidance for specification option:

With no coating or anodized coating.

Fire performance: Reaction to fire to EN 13501-1, Euroclass A2-s1, d0.

Guidance for specification option:

With PPC coating.

Manufacturer guidance

For fire testing:

  • Mineral wool insulation (<340mm thickness) with classification A1 to BS EN 13501-1 was applied on this system.
  • The cavity for the system was 25–100 mm.

Thermal insulation

-

Manufacturer guidance

Insulation, if used, should be mineral wool of classification A1, thickness 50–340 mm. Refer to the Warringtonfire classification report for further details and insert requirements.

Breather membrane

-

Material

-

Manufacturer guidance

The system does not include a breather membrane or vapour barrier since these components are not Class A1. If a vapour barrier is required, refer to the guidance in Approved Document B regarding the required fire classification.

Secondary support structure

AxiAL carrier system.

Guidance for specification option:

Mullion range: 40–140 mm.

AxiAL bracket range: 45–360 mm.

Cavity fire barriers

-

Horizontal

-

Manufacturer guidance

Fire cavity barriers are not included within the system and should be specified and designed by a qualified engineer.

Vertical

-

Manufacturer guidance

Fire cavity barriers are not included within the system and should be specified and designed by a qualified engineer.

Cladding panels

-

Material

3 mm Solid Aluminium.

3 mm Perforated Aluminium.

Manufacturer guidance

Maximum panel size: 5840 x 1340 mm (L x W). Larger panels may require intermediate stiffeners to be fitted.

Panel joints

Baffle joints, 25 mm.

Guidance for specification option:

Standard.

Baffle joints, other.

Guidance for specification option:

Vertical joints and horizontal joints: 20–25 mm. Insert requirements.

Manufacturer guidance

Joint extrusions are mill finished as standard but can be provided in matching or contrasting colours to suit project-specific requirements.


Standard joint width is 25 mm. Miniumum joint width 20 mm.

(Minimum joint 20 mm for individually demountable panel requirements.)

Panel depth

48 mm.

Colour/ Finish

-

Manufacturer guidance

Consult manufacturer and insert requirements.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Similar products from Ash & Lacy

LineAL-F Aluminium Cladding System

LineAL-F Aluminium Cladding System

MechSlip Brick Cladding

MechSlip Brick Cladding

NaturAL-X Brick Cladding

NaturAL-X Brick Cladding

VariAL-CF1 Aluminium Cladding System

VariAL-CF1 Aluminium Cladding System

VariAL-CF2 Aluminium Cladding System

VariAL-CF2 Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-TF Metal Cladding System

VariAL-TF Metal Cladding System